arXiv ScienceSearch

arXiv subjects

I. Yu

Publications and source records attributed to I. Yu.

At least 19 recordsLinked to original sources

First results from the search for an excess of $\bar{\nu}_{e}$ events in JSNS$^2$

The JSNS$^2$ (J-PARC Sterile Neutrino Search at the J-PARC Spallation Neutron Source) experiment at the Material and Life Science Facility (MLF) of J-PARC is designed to directly test an excess on $\bar{\nu}_{e}$ events which was indicated by LSND (Liquid Scintillator Neutrino Detector). The combination of a short-pulsed proton beam and a gadolinium-loaded liquid scintillator provides an excellent signal-to-noise ratio. In this article, we report the first results of a direct test based on data collected in 2022. After applying all event selection criteria, two events are observed, consistent with the expected background of 2.3$\pm$0.4 events. No excess of $\bar{\nu}_e$ events are seen in this report, however the expected number of events due to LSND anomaly is 1.1$\pm$0.5, thus this result is not yet conclusive. Data taking has been ongoing since 2021 and will continue in future runs. In addition, a new far detector has recently been constructed for the second phase experiment, JSNS$^2$-II, marking an important milestone toward forthcoming measurements.

hep-ex

PMT calibration for the JSNS2-II far detector with an embedded LED system

The JSNS2-II (the second phase of JSNS2, J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment aimed at searching for sterile neutrinos. This experiment has entered its second phase, employing two liquid scintillator detectors located at near and far positions from the neutrino source. Recently, the far detector of the experiment has been completed and is currently in the calibration phase. This paper presents a detailed description of the calibration process utilizing the LED system. The LED system of the far detector uses two Ultra-Violet (UV) LEDs, which are effective in calibrating all of PMTs at once. The UV light is converted into the visible light wavelengths inside liquid scintillator via the wavelength shifters, providing pseudo-isotropic light. The properties of all functioning Photo-Multiplier-Tubes (PMTs) to detect the neutrino events in the far detector, such as gain, its dependence of supplied High Voltage (HV), and Peak-to-Valley (PV) were calibrated. To achieve a good energy resolution for physics events, up to 10% of the relative gain adjustment is required for all functioning PMTs. This will be achieved using the measured HV curves and the LED calibration. The Peak-to-Valley (PV) ratio values are the similar to those from the production company, which distinguish the single photo-electron signal from the pedestal. Additionally, the precision of PMT signal timing is measured to be 2.1 ns, meeting the event reconstruction requirement of 10 ns.

physics.ins-det

Muon tagging with Flash ADC waveform baselines

This manuscript describes an innovative method to tag the muons using the baseline information of the Flash ADC (FADC) waveform of PMTs in the JSNS1 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment. This experiment is designed for the search for sterile neutrinos, and a muon tagging is an essential key component for the background rejection since the detector of the experiment is located over-ground, where is the 3rd floor of the J-PARC Material and Life experimental facility (MLF). Especially, stopping muons inside the detector create the Michel electrons, and they are important background to be rejected. Utilizing this innovative method, more than 99.8% of Michel electrons can be rejected even without a detector veto region. This technique can be employed for any experiments which uses the similar detector configurations.

physics.ins-det

Measurement of reactor antineutrino oscillation amplitude and frequency using 3800 days of complete data sample of the RENO experiment

We report an updated neutrino mixing angle of $\theta_{13}$ obtained from a complete data sample of the RENO experiment. The experiment has measured the amplitude and frequency of reactor anti-electron-neutrinos ($\bar{\nu}_{e}$) oscillations at the Hanbit nuclear power plant, Younggwang, Korea, since August 2011. As of March 2023, the data acquisition was completed after a total of 3800 live days of detector operation. The observed candidates via inverse beta decay (IBD) are 1,211,995 (144,667) in the near (far) detector. Based on an observed energy-dependent reactor neutrino disappearance, neutrino oscillation parameters of $\theta_{13}$ and $\lvert\Delta m_{ee}^2\rvert$ are precisely determined as $\sin^{2}2\theta_{13}=0.0920_{-0.0042}^{+0.0044}(\text{stat.})_{-0.0041}^{+0.0041}(\text{syst.})$ and $\lvert\Delta m_{ee}^2\rvert=\left[2.57_{-0.11}^{+0.10}(\text{stat.})_{-0.05}^{+0.05}(\text{syst.})\right]\times10^{-3}~\text{eV}^{2}$. Compared to the previous RENO results published in Ref.~\cite{PhysRevLett.121.201801}, the precision is improved from 7.5\% to 6.4\% for $\sin^{2}2\theta_{13}$ and from 5.2\% to 4.5\% for $\lvert\Delta m_{ee}^2\rvert$. The statistical error of the measurement has reached our goal and is hardly improved with additional data-taking.

hep-ex

The first JSNS$^2$ measurement of electron neutrino flux using $^{12}C(\nu_{e},e^{-}) ^{12}N_{g.s.}$ reaction

JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment searching for sterile neutrinos through the observation of $\bar{\nu}_{\mu} \rightarrow \bar{\nu}_e$ appearance oscillations, using neutrinos produced by muon decay-at-rest. A key aspect of the experiment involves accurately understanding the neutrino flux and the quantities of pions and muons, which are progenitors of (anti-)neutrinos, given that their production rates have yet to be measured. We present the first electron-neutrino flux measurement using $^{12}\mathrm{C}(\nu_{e},e^{-}) ^{12}\mathrm{N}_{g.s.}$ reaction in JSNS$^2$, yielding a flux of (6.7 $\pm$ 1.6 (stat.) $\pm$ 1.7 (syst.)) $\times$ 10$^{-9}$ cm$^{-2}$ proton$^{-1}$ at the JSNS$^2$ detector location, located at 24 meters distance from the mercury target. This flux measurement is consistent with predictions from simulations based on hadron models.

hep-ex

First Measurement of Missing Energy Due to Nuclear Effects in Monoenergetic Neutrino Charged Current Interactions

We present the first measurement of the missing energy due to nuclear effects in monoenergetic, muon neutrino charged-current interactions on carbon, originating from $K^+ \rightarrow \mu^+ \nu_\mu$ decay at rest ($E_{\nu_\mu}=235.5$ MeV), performed with the J-PARC Sterile Neutrino Search at the J-PARC Spallation Neutron Source liquid scintillator based experiment. Toward characterizing the neutrino interaction, ostensibly $\nu_\mu n \rightarrow \mu^- p$ or $\nu_\mu$$^{12}\mathrm{C}$ $\rightarrow \mu^-$$^{12}\mathrm{N}$, we define the missing energy as the energy transferred to the nucleus ($\omega$) minus the kinetic energy of the outgoing proton(s), $E_{m} \equiv\omega-\sum T_p$, and relate this to visible energy in the detector, $E_{m}=E_{\nu_\mu} (235.5 \mathrm{MeV})-m_\mu (105.7 \mathrm{MeV}) + [m_n-m_p (1.3 \mathrm{MeV})] - E_{\mathrm{vis}}$. The missing energy, which is naively expected to be zero in the absence of nuclear effects (e.g. nucleon separation energy, Fermi momenta, and final-state interactions), is uniquely sensitive to many aspects of the interaction, and has previously been inaccessible with neutrinos. The shape-only, differential cross section measurement reported, based on a $(77\pm3)$% pure double-coincidence kaon decay-at-rest signal (621 total events), provides detailed insight into neutrino-nucleus interactions, allowing even the nuclear orbital shell of the struck nucleon to be inferred. The measurement provides an important benchmark for models and event generators at hundreds of MeV neutrino energies, characterized by the difficult-to-model transition region between neutrino-nucleus and neutrino-nucleon scattering, and relevant for applications in nuclear physics, neutrino oscillation measurements,and Type-II supernova studies.

hep-ex

Evaluation of the performance of the event reconstruction algorithms in the JSNS$^2$ experiment using a $^{252}$Cf calibration source

JSNS$^2$ searches for short baseline neutrino oscillations with a baseline of 24~meters and a target of 17~tonnes of the Gd-loaded liquid scintillator. The correct algorithm on the event reconstruction of events, which determines the position and energy of neutrino interactions in the detector, are essential for the physics analysis of the data from the experiment. Therefore, the performance of the event reconstruction is carefully checked with calibrations using $^{252}$Cf source. This manuscript describes the methodology and the performance of the event reconstruction.

hep-ex

Pulse Shape Discrimination in JSNS$^2$

JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment that is searching for sterile neutrinos via the observation of $\bar{\nu}_{\mu} \rightarrow \bar{\nu}_e$ appearance oscillations using neutrinos with muon decay-at-rest. For this search, rejecting cosmic-ray-induced neutron events by Pulse Shape Discrimination (PSD) is essential because the JSNS$^2$ detector is located above ground, on the third floor of the building. We have achieved 95$\%$ rejection of neutron events while keeping 90$\%$ of signal, electron-like events using a data driven likelihood method.

physics.ins-det

The acrylic vessel for JSNS$^{2}$-II neutrino target

The JSNS$^{2}$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment designed for the search for sterile neutrinos. The experiment is currently at the stage of the second phase named JSNS$^{2}$-II with two detectors at near and far locations from the neutrino source. One of the key components of the experiment is an acrylic vessel, that is used for the target volume for the detection of the anti-neutrinos. The specifications, design, and measured properties of the acrylic vessel are described.

hep-ex

Study on the accidental background of the JSNS$^2$ experiment

JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment which searches for sterile neutrinos via the observation of $\bar{\nu}_{\mu} \to \bar{\nu}_{e}$ appearance oscillations using muon decay-at-rest neutrinos. The data taking of JSNS$^2$ have been performed from 2021. In this manuscript, a study of the accidental background is presented. The rate of the accidental background is (9.29$\pm 0.39) \times 10^{-8}$ / spill with 0.75 MW beam power and comparable to the number of searching signals.

hep-ex

Machine Learning based tool for CMS RPC currents quality monitoring

The muon system of the CERN Compact Muon Solenoid (CMS) experiment includes more than a thousand Resistive Plate Chambers (RPC). They are gaseous detectors operated in the hostile environment of the CMS underground cavern on the Large Hadron Collider where pp luminosities of up to $2\times 10^{34}$ $\text{cm}^{-2}\text{s}^{-1}$ are routinely achieved. The CMS RPC system performance is constantly monitored and the detector is regularly maintained to ensure stable operation. The main monitorable characteristics are dark current, efficiency for muon detection, noise rate etc. Herein we describe an automated tool for CMS RPC current monitoring which uses Machine Learning techniques. We further elaborate on the dedicated generalized linear model proposed already and add autoencoder models for self-consistent predictions as well as hybrid models to allow for RPC current predictions in a distant future.

physics.ins-det

RPC based tracking system at CERN GIF++ facility

With the HL-LHC upgrade of the LHC machine, an increase of the instantaneous luminosity by a factor of five is expected and the current detection systems need to be validated for such working conditions to ensure stable data taking. At the CERN Gamma Irradiation Facility (GIF++) many muon detectors undergo such studies, but the high gamma background can pose a challenge to the muon trigger system which is exposed to many fake hits from the gamma background. A tracking system using RPCs is implemented to clean the fake hits, taking profit of the high muon efficiency of these chambers. This work will present the tracking system configuration, used detector analysis algorithm and results.

physics.ins-det

Pulse shape discrimination using a convolutional neural network for organic liquid scintillator signals

A convolutional neural network (CNN) architecture is developed to improve the pulse shape discrimination (PSD) power of the gadolinium-loaded organic liquid scintillation detector to reduce the fast neutron background in the inverse beta decay candidate events of the NEOS-II data. A power spectrum of an event is constructed using a fast Fourier transform of the time domain raw waveforms and put into CNN. An early data set is evaluated by CNN after it is trained using low energy $\beta$ and $\alpha$ events. The signal-to-background ratio averaged over 1-10 MeV visible energy range is enhanced by more than 20% in the result of the CNN method compared to that of an existing conventional PSD method, and the improvement is even higher in the low energy region.

physics.ins-det

Measurement of cosmogenic $^9$Li and $^8$He production rates at RENO

We report the measured production rates of unstable isotopes $^9$Li and $^8$He produced by cosmic muon spallation on $^{12}$C using two identical detectors of the RENO experiment. Their beta-decays accompanied by a neutron make a significant contribution to backgrounds of reactor antineutrino events in precise determination of the smallest neutrino mixing angle. The mean muon energy of its near (far) detector with an overburden of 120 (450) m.w.e. is estimated as 33.1 +- 2.3 (73.6 +- 4.4) GeV. Based on roughly 3100 days of data, the cosmogenic production rate of $^9$Li ($^8$He) isotope is measured to be 44.2 +- 3.1 (10.6 +- 7.4) per day at near detector and 10.0 +- 1.1 (2.1 +- 1.5) per day at far detector. This corresponds to yields of $^9$Li ($^8$He), 4.80 +- 0.36 (1.15 +- 0.81) and 9.9 +- 1.1 (2.1 +- 1.5) at near and far detectors, respectively, in a unit of 10$^{-8}$ $\mu^{-1}$ g${^-1}$ cm${^2}$. Combining the measured $^9$Li yields with other available underground measurements, an excellent power-law relationship of the yield with respect to the mean muon energy is found to have an exponent of $\alpha$ = 0.75 +- 0.05.

nucl-ex

Characterization of the correlated background for a sterile neutrino search using the first dataset of the JSNS$^2$ experiment

JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment that is searching for sterile neutrinos via the observation of $\bar{\nu}_{\mu} \to \bar{\nu}_{e}$ appearance oscillations using muon decay-at-rest neutrinos. Before dedicated data taking in the first-half of 2021, we performed a commissioning run for 10 days in June 2020. Using the data obtained in this commissioning run, in this paper, we present an estimate of the correlated background which imitates the $\bar{\nu}_{e}$ signal in a sterile neutrino search. In addition, in order to demonstrate future prospects of the JSNS$^2$ experiment, possible pulse shape discrimination improvements towards reducing cosmic ray induced fast neutron background are described.

hep-ex

The JSNS^2 Detector

The JSNS^2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for oscillations involving a sterile neutrino in the eV^2 mass-splitting range. The experiment will search for the appearance of electron antineutrinos oscillated from muon antineutrinos. The electron antineutrinos are detected via the inverse beta decay process using a liquid scintillator detector. A 1MW beam of 3 GeV protons incident on a spallation neutron target produces an intense and pulsed neutrino source from pion, muon, and kaon decay at rest. The JSNS^2 detector is located 24 m away from the neutrino source and began operation from June 2020. The detector contains 17 tonnes of gadolinium (Gd) loaded liquid scintillator (LS) in an acrylic vessel, as a neutrino target. It is surrounded by 31 tonnes of unloaded LS in a stainless steel tank. Optical photons produced in LS are viewed by 120 R7081 Hamamatsu 10-inch Photomultiplier Tubes (PMTs). In this paper, we describe the JSNS^2 detector design, construction, and operation.

physics.ins-det

Proposal: JSNS$^2$-II

This article describes the goal and expected sensitivity of the JSNS$^2$-II experiment at J-PARC Materials and Life Science Experimental Facility (MLF). The JSNS$^2$-II experiment is the second phase of the JSNS$^2$ experiment (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) with two detectors which are located in 24 m (an existing detector) and 48 m (new one) baselines to improve the sensitivity of the search for sterile neutrinos, especially in the low $\Delta m^2$ region, which has been indicated by the global fit of the appearance mode. The new second detector has a similar structure as the existing JSNS$^2$ detector, which is already working. To compensate for the reduction of the neutrino flux due to the distance from the mercury target, the target mass of the Gd-loaded liquid scintillator which is the Linear AlkylBenzene (LAB) based liquid scintillator inside the acrylic vessel is 35 tons. To keep the same photo-coverage of the detector as the first detector, we will surround the acrylic vessel with 240 PMTs. With this experimental setup and 5 years (times 1 MW beam power) exposure, the sensitivity of the JSNS$^2$-II is significantly improved compared to the current JSNS$^2$, especially in the low $\Delta m^2$ oscillation parameter region. The JSNS$^2$-II can also confirm or refute the most of the oscillation parameters' space preferred by the previous experiments with 3 sigma C.L.. Considering these situations and world wide status of the sterile neutrino searches, we are eager to start the data taking with the two detector configuration from 2023. The fund to build the second detector was already secured.

hep-ex

Search for sterile neutrino oscillation using RENO and NEOS data

We present a reactor model independent search for sterile neutrino oscillation using 2\,509\,days of RENO near detector data and 180 days of NEOS data. The reactor related systematic uncertainties are significantly suppressed as both detectors are located at the same reactor complex of Hanbit Nuclear Power Plant. The search is performed by electron antineutrino\,($\overline{\nu}_e$) disappearance between six reactors and two detectors with baselines of 294\,m\,(RENO) and 24\,m\,(NEOS). A spectral comparison of the NEOS prompt-energy spectrum with a no-oscillation prediction from the RENO measurement can explore reactor $\overline{\nu}_e$ oscillations to sterile neutrino. Based on the comparison, we obtain a 95\% C.L. excluded region of $0.1<|\Delta m_{41}^2|<7$\,eV$^2$. We also obtain a 68\% C.L. allowed region with the best fit of $|\Delta m_{41}^2|=2.41\,\pm\,0.03\,$\,eV$^2$ and $\sin^2 2\theta_{14}$=0.08$\,\pm\,$0.03 with a p-value of 8.2\%. Comparisons of obtained reactor antineutrino spectra at reactor sources are made among RENO, NEOS, and Daya Bay to find a possible spectral variation.

hep-ex