arXiv ScienceSearch

arXiv subjects

I. Fan

Publications and source records attributed to I. Fan.

6 recordsLinked to original sources

Revisiting $^{129}$Xe electric dipole moment measurements applying a new global phase fitting approach

By measuring the nuclear magnetic spin precession frequencies of polarized $^{129}$Xe and $^{3}$He, a new upper limit on the $^{129}$Xe atomic electric dipole moment (EDM) $ d_\mathrm{A} (^{129}\mathrm{Xe})$ was reported in Phys. Rev. Lett. 123, 143003 (2019). Here, we propose a new evaluation method based on global phase fitting (GPF) for analyzing the continuous phase development of the $^{3}$He-$^{129}$Xe comagnetometer signal. The Cramer-Rao Lower Bound on the $^{129}$Xe EDM for the GPF method is theoretically derived and shows the potential benefit of our new approach. The robustness of the GPF method is verified with Monte-Carlo studies. By optimizing the analysis parameters and adding data that could not be analyzed with the former method, we obtain a result of $d_\mathrm{A} (^{129}\mathrm{Xe}) = 1.1 \pm 3.6~\mathrm{(stat)} \pm 2.0~\mathrm{(syst)} \times 10^{-28}~ e~\mathrm{cm}$ in an unblinded analysis. For the systematic uncertainty analyses, we adopted all methods from the aforementioned PRL publication except the comagnetometer phase drift, which can be omitted using the GPF method. The updated null result can be interpreted as a new upper limit of $| d_\mathrm{A} (^{129}\mathrm{Xe}) | < 8.3 \times 10^{-28}~e~\mathrm{cm}$ at the 95\% C.L.

physics.atom-ph

New Limit on the Permanent Electric Dipole Moment of $^{129}$Xe using $^{3}$He Comagnetometry and SQUID Detection

We report results of a new technique to measure the electric dipole moment of $^{129}$Xe with $^3$He comagnetometry. Both species are polarized using spin-exchange optical pumping, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result from a one week measurement campaign in 2017 and a 2.5 week campaign in 2018, combined with detailed study of systematic effects, is $d_A(^{129}\mathrm{Xe}) = (1.4 \pm 6.6_\mathrm{stat} \pm 2.0_\mathrm{syst})\times10^{-28}~e\,\mathrm{cm}$. This corresponds to an upper limit of $|d_A(^{129}\mathrm{Xe})| < 1.4 \times 10^{-27} ~e\,\mathrm{cm}~(95\%~\mathrm{CL})$, a factor of five more sensitive than the limit set in 2001.

physics.atom-ph

A new measurement of the permanent electric dipole moment of $^{129}$Xe using $^{3}$He comagnetometry and SQUID detection

We describe a new technique to measure the EDM of $^{129}$Xe with $^3$He comagnetometry. Both species are polarized using spin-exchange optical pumping, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result of a one week run combined with a detailed study of systematic effects is $d_A(^{129}\mathrm{Xe}) = (0.26 \pm 2.33_\mathrm{stat} \pm 0.72_\mathrm{syst})\times10^{-27}~e\,\mathrm{cm}$. This corresponds to an upper limit of $|d_A(^{129}\mathrm{Xe})| < 4.81\times 10^{-27} ~e\,\mathrm{cm}~(95\%~\mathrm{CL})$, a factor of 1.4 more sensitive than the previous limit.

physics.atom-ph

A magnetically shielded room with ultra low residual field and gradient

A versatile and portable magnetically shielded room with a field of (700 \pm 200) pT within a central volume of 1m x 1m x 1m and a field gradient less than 300 pT/m is described. This performance represents more than a hundred-fold improvement of the state of the art for a two-layer magnetic shield and provides an environment suitable for a next generation of precision experiments in fundamental physics at low energies; in particular, searches for electric dipole moments of fundamental systems and tests of Lorentz-invariance based on spin-precession experiments. Studies of the residual fields and their sources enable improved design of future ultra-low gradient environments and experimental apparatus.

physics.ins-det

$\beta$ NMR study of Isolated $^8$Li in the enhanced paramagnet Platinum

We report {\beta} detected nuclear magnetic resonance ({\beta}NMR) measurements of 8Li+ implanted into high purity Pt. The frequency of the 8Li {\beta}NMR resonance and the spin-lattice relaxation rates 1/T1 were measured at temperatures ranging from 3 to 300 K. Remarkably, both the spin-lattice relaxation rate and the Knight shift K depend linearly on temperature T although the bulk susceptibility does not. K is found to scale with the Curie-Weiss dependence of the Pt susceptibility extrapolated to low temperatures. This is attributed to a defect response of the enhanced paramagnetism of Pt, i.e. the presence of the interstitial Li+ locally relieves the tendency for the Curie-Weiss susceptibility to saturate at low T . We propose that the low temperature saturation in \c{hi} of Pt may be related to an interband coupling between the s and d bands that is disrupted locally by the presence of the Li+.

cond-mat.str-el

$β$-NMR of Isolated $^{8}$Li$^{+}$ Implanted into a Thin Copper Film

Depth-controlled $β$-NMR was used to study highly spin-polarized $^8$Li in a Cu film of thickness 100 nm deposited onto a MgO substrate. The positive Knight Shifts and spin relaxation data show that $^8$Li occupies two sites at low temperatures, assigned to be the substitutional ($S$) and octahedral ($O$) interstitial sites. Between 50 to 100 K, there is a site change from $O$ to $S$. The temperature dependence of the Knight shifts and spin-lattice relaxation rates at high temperatures, i.e. when all the Li are in the $S$ site, is consistent with the Korringa Law for a simple metal.

cond-mat.str-el