arXiv Science⌕ Search

arXiv subjects

I. Cojocari

Publications and source records attributed to I. Cojocari.

4 recordsLinked to original sources

Development of millikelvin scintillation photodetectors with CUPID

CUPID is a next-generation tonne-scale cryogenic experiment that will search for the neutrinoless double beta decay $(0νββ)$ of $^{100}$Mo. It will be located at the Gran Sasso National Laboratory (Italy) and will employ the cryogenic calorimetric technique to reconstruct the energy deposited in Li$_{2}$MoO$_{4}$ crystals, in which the isotope of interest is embedded. Preliminary measurements have been performed with the CUPID VSTT (Vertical Slice Test Tower), a prototype tower designed to test the detectors' response and the apparatus' mechanical and thermal stability. In addition, a key objective was to demonstrate the improved performance of germanium-based cryogenic light detectors. In CUPID, light detection is used for both particle identification and pile-up rejection. Li$_{2}$MoO$_{4}$ is a scintillating crystal, enabling particle identification by exploiting the dependence of light yield on particle type. This requires collecting the Li$_{2}$MoO$_{4}$ scintillation light, peaking at $\sim$600 nm, with a $\sim$300 $μ$m-thick high-purity germanium wafer placed next to the crystal. The wafer is also equipped with concentric Al electrodes biased at a few tens of volts. This bias improves the signal-to-noise ratio by an order of magnitude thanks to the Neganov-Trofimov-Luke effect. This work presents preliminary results on the performance of the VSTT light detectors and of its Optical Injection System.

physics.ins-det↗

Observation of Non-Equilibrium Phonon Loss Across a Solid-Superfluid Interface

We measure the performance of an athermal phonon calorimeter in vacuum and in thermal contact with superfluid $^4$He. Using a cryogenic photon calibration system, we show that the superfluid suppresses the collection of the phonon signal by over 99\%. We conclude that submerged sensors will not benefit TESSERACT's superfluid helium dark matter target, but that superfluid helium may be useful to superconducting qubits as a sink for athermal phonons generated by radiation and other spontaneous sources. Our measurement is the first probe of solid-to-superfluid phonon transmission at energies higher than those stably supportable by the superfluid. We discuss thermal flow inside the calorimeter, as well as systematics from an alternative calibration scheme.

physics.ins-det↗

The CROSS experiment: detector construction, background projection, and sensitivity to $^{100}$Mo $0\nu2β$ decay

The CROSS experiment to search for neutrinoless double-beta ($0\nu2β$) decay in $^{100}$Mo with the help of an array of scintillating cryogenic calorimeters, containing 4.9 kg of $^{100}$Mo, has been ongoing in a low-background setup at the Canfranc underground laboratory (Spain) since mid-November 2025. In this paper, we present the construction of the CROSS detector and the description of Geant4-based Monte Carlo simulations of expected background in the region of interest. The simulations predict the background index in a 100-keV-wide interval centered at the $Q$-value of $^{100}$Mo (3034 keV) on the level of 3.2(5) $\times$ 10$^{-3}$ cnts/keV/kg/yr. Taking into account an 18% deadtime induced by the muon veto cut and a typical 90% duty cycle of the facility, such background level would allow to reach the world-leading sensitivity to $^{100}$Mo $0\nu2β$ decay (lim $T_{1/2} \sim 4 \times 10^{24}$ yr) in 1 year of data taking. Considering conservatively a factor 3 (10) worse background index due to unpredictable radioactive contamination of construction materials and/or detector performance, a 2-yr-long operation of the CROSS array would be still compatible with the best (competitive) sensitivity to $0\nu2β$ decay in $^{100}$Mo.

physics.ins-det↗

Low Energy Phonon Bursts Created By Fast Neutron Damage

Solid state athermal phonon calorimeters used in the search for low mass dark matter or coherent neutrino-nucleus interactions have long observed a large excess of events below several hundred eV. The relaxation of damage created by the interaction of fast cosmic ray neutrons with the detector has been proposed as a source of these excess events. By comparing neutron exposed detectors to control detectors, we report the first measurement of phonon bursts caused by damage created by fast neutrons. Differences in the spectral shape, the rate dependence on thermal history, and the observed spectral rate scaled to the neutron exposure between irradiated and control detectors suggest that our observed LEE backgrounds are not dominated by neutron damage-induced phonon bursts.

physics.ins-det↗