arXiv Science⌕ Search

arXiv subjects

Huadong Sun

Publications and source records attributed to Huadong Sun.

3 recordsLinked to original sources

PLL-Less Synchronization of Grid-Following Converters Using a Voltage-Driven Frenet Frame

In grid-following converters, the synchronization path can transmit voltage disturbances to the current loop under weak or unbalanced grid conditions. This paper develops a Frenet-frame controller that derives its axes from the integral curve of the measured voltage at the point of common coupling. The tangential current governs active power, while the normal and binormal currents govern the transverse components of non-active power. Feedforward terms derived from the output filter model compensate curvature and torsion coupling, yielding identical nominal current dynamics across the axes. The controller operates without a phase-locked loop or sequence extraction. A reduced transverse model accounts for the finite bandwidth of geometric rate reconstruction and predicts a reduction in low-frequency coupling from voltage disturbances to current. Controller hardware-in-the-loop tests using real-time simulation of a three-phase four-wire converter show the shortest settling time after an active power reference step and the smallest peak power deviations during balanced voltage disturbances among the tested controllers. Under single-phase voltage unbalance, the method reduces peak binormal current and maximum phase-current total harmonic distortion relative to both benchmarks. It also settles to the commanded power in a weak-grid connection test where the phase-locked loop benchmark exhibits sustained oscillations.

eess.SY↗

Response-Based Frequency Stability Assessment under Multi-Scale Disturbances in High-Renewable Power Systems

In high-renewable power systems, active-power disturbances are becoming larger and exhibit increasingly diverse time scales, which complicates frequency stability assessment under unanticipated events. This paper presents a response-based frequency stability assessment method that uses disturbance power, inferred from generator electrical responses, to provide a unified treatment of multi-scale disturbances. Unanticipated disturbances are first classified into short-term and permanent events; permanent disturbances are further divided into step, second-level slope and minute-level slope disturbances. Based on the measured power responses of generator groups, a unified disturbance-power model is constructed to identify the disturbance type online and to quantify disturbance intensity through the disturbance power and its rate of change. Analytical frequency-response models are then derived for each disturbance class. For step disturbances, the maximum tolerable disturbance power is obtained under steady-state and transient frequency deviation constraints, and a safety-margin index is defined. For slope-type disturbances, an improved system frequency response (SFR) model and the rotor motion equation after exhaustion of primary frequency regulation are used to compute the over-limit time of frequency deviation. The proposed response-based assessment method is validated on the CSEE-FS frequency-stability benchmark system, demonstrating its effectiveness and accuracy for quantitative frequency stability assessment in high-renewable power systems.

eess.SY↗

Transient Stability of Low-Inertia Power Systems with Inverter-Based Generation

This study examines the transient stability of low-inertia power systems with inverter-based generation (IBG) and proposes a sufficient stability criterion. In low-inertia grids, transient interactions are induced between the electromagnetic dynamics of the IBG and the electromechanical dynamics of the synchronous generator (SG) under a fault. For this, a hybrid IBG-SG system is established and a delta-power-frequency model is developed. Based on this model, new mechanisms of transient instability different from those of conventional power systems from the energy perspective are discovered. First, two loss-of-synchronization (LOS) types are identified based on the relative power imbalance owing to the mismatch between the inertia of the IBG and SG under a fault. Second, the relative angle and frequency will jump at the moment of a fault, thus affecting the system energy. Third, the cosine damping coefficient induces a positive energy dissipation, thereby contributing to the system stability. A unified criterion for identifying the two LOS types is proposed using the energy function method. This criterion is proved to be a sufficient stability condition for addressing the effects of the jumps and cosine damping coefficient on the system stability. The new mechanisms and effectiveness of the criterion are verified based on simulation results.

eess.SY↗