arXiv Science⌕ Search

arXiv subjects

Hongliang Ren

Publications and source records attributed to Hongliang Ren.

At least 55 records · Page 3Linked to original sources

MedScope: Incentivizing "Think with Videos" for Clinical Reasoning via Coarse-to-Fine Tool Calling

Long-form clinical videos are central to visual evidence-based decision-making, with growing importance for applications such as surgical robotics and related settings. However, current multimodal large language models typically process videos with passive sampling or weakly grounded inspection, which limits their ability to iteratively locate, verify, and justify predictions with temporally targeted evidence. To close this gap, we propose MedScope, a tool-using clinical video reasoning model that performs coarse-to-fine evidence seeking over long-form procedures. By interleaving intermediate reasoning with targeted tool calls and verification on retrieved observations, MedScope produces more accurate and trustworthy predictions that are explicitly grounded in temporally localized visual evidence. To address the lack of high-fidelity supervision, we build ClinVideoSuite, an evidence-centric, fine-grained clinical video suite. We then optimize MedScope with Grounding-Aware Group Relative Policy Optimization (GA-GRPO), which directly reinforces tool use with grounding-aligned rewards and evidence-weighted advantages. On full and fine-grained video understanding benchmarks, MedScope achieves state-of-the-art performance in both in-domain and out-of-domain evaluations. Our approach illuminates a path toward medical AI agents that can genuinely "think with videos" through tool-integrated reasoning. We will release our code, models, and data.

cs.CV↗

Bioinspired Kirigami Capsule Robot for Minimally Invasive Gastrointestinal Biopsy

Wireless capsule endoscopy (WCE) has transformed gastrointestinal (GI) diagnostics by enabling noninvasive visualization of the digestive tract, yet its diagnostic yield remains constrained by the absence of biopsy capability, as histological analysis is still the gold standard for confirming disease. Conventional biopsy using forceps, needles, or rotating blades is invasive, limited in reach, and carries risks of perforation or mucosal trauma, while fluid- or microbiota-sampling capsules cannot provide structured tissue for pathology, leaving a critical gap in swallowable biopsy solutions. Here we present the Kiri-Capsule, a kirigami-inspired capsule robot that integrates deployable PI-film flaps actuated by a compact dual-cam mechanism to achieve minimally invasive and repeatable tissue collection. The kirigami surface remains flat during locomotion but transforms into sharp protrusions upon cam-driven stretching, enabling controlled penetration followed by rotary scraping, with specimens retained in internal fan-shaped cavities. Bench tests confirmed that PI films exhibit a Young's modulus of approximately 20 MPa and stable deployment angles (about 34$^\circ$ at 15% strain), while ex vivo porcine studies demonstrated shallow penetration depths (median $\sim$0.61 mm, range 0.46--0.66 mm) and biopsy yields comparable to standard forceps (mean $\sim$10.9 mg for stomach and $\sim$18.9 mg for intestine), with forces within safe ranges reported for GI biopsy. These findings demonstrate that the Kiri-Capsule bridges passive imaging and functional biopsy, providing a swallowable, depth-controlled, and histology-ready solution that advances capsule-based diagnostics toward safe and effective clinical application.

cs.RO↗

GeoLanG: Geometry-Aware Language-Guided Grasping with Unified RGB-D Multimodal Learning

Language-guided grasping has emerged as a promising paradigm for enabling robots to identify and manipulate target objects through natural language instructions, yet it remains highly challenging in cluttered or occluded scenes. Existing methods often rely on multi-stage pipelines that separate object perception and grasping, which leads to limited cross-modal fusion, redundant computation, and poor generalization in cluttered, occluded, or low-texture scenes. To address these limitations, we propose GeoLanG, an end-to-end multi-task framework built upon the CLIP architecture that unifies visual and linguistic inputs into a shared representation space for robust semantic alignment and improved generalization. To enhance target discrimination under occlusion and low-texture conditions, we explore a more effective use of depth information through the Depth-guided Geometric Module (DGGM), which converts depth into explicit geometric priors and injects them into the attention mechanism without additional computational overhead. In addition, we propose Adaptive Dense Channel Integration, which adaptively balances the contributions of multi-layer features to produce more discriminative and generalizable visual representations. Extensive experiments on the OCID-VLG dataset, as well as in both simulation and real-world hardware, demonstrate that GeoLanG enables precise and robust language-guided grasping in complex, cluttered environments, paving the way toward more reliable multimodal robotic manipulation in real-world human-centric settings.

cs.RO↗

SurgVidLM: Towards Multi-grained Surgical Video Understanding with Large Language Model

Surgical scene understanding is critical for surgical training and robotic decision-making in robot-assisted surgery. Recent advances in Multimodal Large Language Models (MLLMs) have demonstrated great potential for advancing scene perception in the medical domain, facilitating surgeons to understand surgical scenes and procedures. However, these methods are primarily oriented towards image-based analysis or global video understanding, overlooking the fine-grained video reasoning that is crucial for analyzing specific processes and capturing detailed task execution within a surgical procedure. To bridge this gap, we propose SurgVidLM, the first video language model designed to address both full and fine-grained surgical video comprehension. To train our SurgVidLM, we construct the SVU-31K that is a large-scale dataset with over 31K video-instruction pairs, enabling both holistic understanding and detailed analysis of surgical procedures. Building on this resource, SurgVidLM incorporates a two-stage StageFocus mechanism: the first stage extracts global procedural context, while the second stage performs high-frequency local analysis guided by temporal cues. We also develop the Multi-frequency Fusion Attention to effectively integrate low- and high-frequency visual tokens, ensuring the preservation of critical task-specific details. Experimental results demonstrate that SurgVidLM significantly outperforms state-of-the-art Vid-LLMs of comparable parameter scale in both full and fine-grained video understanding tasks, showcasing its superior capability in capturing the context of complex robot-assisted surgeries. Our code and dataset will be publicly accessible soon.

cs.CV↗

Comparative validation of surgical phase recognition, instrument keypoint estimation, and instrument instance segmentation in endoscopy: Results of the PhaKIR 2024 challenge

Reliable recognition and localization of surgical instruments in endoscopic video recordings are foundational for a wide range of applications in computer- and robot-assisted minimally invasive surgery (RAMIS), including surgical training, skill assessment, and autonomous assistance. However, robust performance under real-world conditions remains a significant challenge. Incorporating surgical context - such as the current procedural phase - has emerged as a promising strategy to improve robustness and interpretability. To address these challenges, we organized the Surgical Procedure Phase, Keypoint, and Instrument Recognition (PhaKIR) sub-challenge as part of the Endoscopic Vision (EndoVis) challenge at MICCAI 2024. We introduced a novel, multi-center dataset comprising thirteen full-length laparoscopic cholecystectomy videos collected from three distinct medical institutions, with unified annotations for three interrelated tasks: surgical phase recognition, instrument keypoint estimation, and instrument instance segmentation. Unlike existing datasets, ours enables joint investigation of instrument localization and procedural context within the same data while supporting the integration of temporal information across entire procedures. We report results and findings in accordance with the BIAS guidelines for biomedical image analysis challenges. The PhaKIR sub-challenge advances the field by providing a unique benchmark for developing temporally aware, context-driven methods in RAMIS and offers a high-quality resource to support future research in surgical scene understanding.

cs.CV↗

Where It Moves, It Matters: Referring Surgical Instrument Segmentation via Motion

Enabling intuitive, language-driven interaction with surgical scenes is a critical step toward intelligent operating rooms and autonomous surgical robotic assistance. However, the task of referring segmentation, localizing surgical instruments based on natural language descriptions, remains underexplored in surgical videos, with existing approaches struggling to generalize due to reliance on static visual cues and predefined instrument names. In this work, we introduce SurgRef, a novel motion-guided framework that grounds free-form language expressions in instrument motion, capturing how tools move and interact across time, rather than what they look like. This allows models to understand and segment instruments even under occlusion, ambiguity, or unfamiliar terminology. To train and evaluate SurgRef, we present Ref-IMotion, a diverse, multi-institutional video dataset with dense spatiotemporal masks and rich motion-centric expressions. SurgRef achieves state-of-the-art accuracy and generalization across surgical procedures, setting a new benchmark for robust, language-driven surgical video segmentation.

cs.CV↗

More than Segmentation: Benchmarking SAM 3 for Segmentation, 3D Perception, and Reconstruction in Robotic Surgery

The recent SAM 3 and SAM 3D have introduced significant advancements over the predecessor, SAM 2, particularly with the integration of language-based segmentation and enhanced 3D perception capabilities. SAM 3 supports zero-shot segmentation across a wide range of prompts, including point, bounding box, and language-based prompts, allowing for more flexible and intuitive interactions with the model. In this empirical evaluation, we assess the performance of SAM 3 in robot-assisted surgery, benchmarking its zero-shot segmentation with point and bounding box prompts and exploring its effectiveness in dynamic video tracking, alongside its newly introduced language prompt segmentation. While language prompts show potential, their performance in the surgical domain is currently suboptimal, highlighting the need for further domain-specific training. Additionally, we investigate SAM 3D's depth reconstruction abilities, demonstrating its capacity to process surgical scene data and reconstruct 3D anatomical structures from 2D images. Through comprehensive testing on the MICCAI EndoVis 2017 and EndoVis 2018 benchmarks, SAM 3 shows clear improvements over SAM and SAM 2 in both image and video segmentation under spatial prompts, while the zero-shot evaluations of SAM 3D on SCARED, StereoMIS, and EndoNeRF indicate strong monocular depth estimation and realistic 3D instrument reconstruction, yet also reveal remaining limitations in complex, highly dynamic surgical scenes.

cs.CV↗

NeuroABench: A Multimodal Evaluation Benchmark for Neurosurgical Anatomy Identification

Multimodal Large Language Models (MLLMs) have shown significant potential in surgical video understanding. With improved zero-shot performance and more effective human-machine interaction, they provide a strong foundation for advancing surgical education and assistance. However, existing research and datasets primarily focus on understanding surgical procedures and workflows, while paying limited attention to the critical role of anatomical comprehension. In clinical practice, surgeons rely heavily on precise anatomical understanding to interpret, review, and learn from surgical videos. To fill this gap, we introduce the Neurosurgical Anatomy Benchmark (NeuroABench), the first multimodal benchmark explicitly created to evaluate anatomical understanding in the neurosurgical domain. NeuroABench consists of 9 hours of annotated neurosurgical videos covering 89 distinct procedures and is developed using a novel multimodal annotation pipeline with multiple review cycles. The benchmark evaluates the identification of 68 clinical anatomical structures, providing a rigorous and standardized framework for assessing model performance. Experiments on over 10 state-of-the-art MLLMs reveal significant limitations, with the best-performing model achieving only 40.87% accuracy in anatomical identification tasks. To further evaluate the benchmark, we extract a subset of the dataset and conduct an informative test with four neurosurgical trainees. The results show that the best-performing student achieves 56% accuracy, with the lowest scores of 28% and an average score of 46.5%. While the best MLLM performs comparably to the lowest-scoring student, it still lags significantly behind the group's average performance. This comparison underscores both the progress of MLLMs in anatomical understanding and the substantial gap that remains in achieving human-level performance.

cs.CV↗

Bridging Vision and Language for Robust Context-Aware Surgical Point Tracking: The VL-SurgPT Dataset and Benchmark

Accurate point tracking in surgical environments remains challenging due to complex visual conditions, including smoke occlusion, specular reflections, and tissue deformation. While existing surgical tracking datasets provide coordinate information, they lack the semantic context necessary to understand tracking failure mechanisms. We introduce VL-SurgPT, the first large-scale multimodal dataset that bridges visual tracking with textual descriptions of point status in surgical scenes. The dataset comprises 908 in vivo video clips, including 754 for tissue tracking (17,171 annotated points across five challenging scenarios) and 154 for instrument tracking (covering seven instrument types with detailed keypoint annotations). We establish comprehensive benchmarks using eight state-of-the-art tracking methods and propose TG-SurgPT, a text-guided tracking approach that leverages semantic descriptions to improve robustness in visually challenging conditions. Experimental results demonstrate that incorporating point status information significantly improves tracking accuracy and reliability, particularly in adverse visual scenarios where conventional vision-only methods struggle. By bridging visual and linguistic modalities, VL-SurgPT enables the development of context-aware tracking systems crucial for advancing computer-assisted surgery applications that can maintain performance even under challenging intraoperative conditions.

cs.CV↗

Contact-Aided Navigation of Flexible Robotic Endoscope Using Deep Reinforcement Learning in Dynamic Stomach

Navigating a flexible robotic endoscope (FRE) through the gastrointestinal tract is critical for surgical diagnosis and treatment. However, navigation in the dynamic stomach is particularly challenging because the FRE must learn to effectively use contact with the deformable stomach walls to reach target locations. To address this, we introduce a deep reinforcement learning (DRL) based Contact-Aided Navigation (CAN) strategy for FREs, leveraging contact force feedback to enhance motion stability and navigation precision. The training environment is established using a physics-based finite element method (FEM) simulation of a deformable stomach. Trained with the Proximal Policy Optimization (PPO) algorithm, our approach achieves high navigation success rates (within 3 mm error between the FRE's end-effector and target) and significantly outperforms baseline policies. In both static and dynamic stomach environments, the CAN agent achieved a 100% success rate with 1.6 mm average error, and it maintained an 85% success rate in challenging unseen scenarios with stronger external disturbances. These results validate that the DRL-based CAN strategy substantially enhances FRE navigation performance over prior methods.

cs.RO↗

Jacobian Exploratory Dual-Phase Reinforcement Learning for Dynamic Endoluminal Navigation of Deformable Continuum Robots

Deformable continuum robots (DCRs) present unique planning challenges due to nonlinear deformation mechanics and partial state observability, violating the Markov assumptions of conventional reinforcement learning (RL) methods. While Jacobian-based approaches offer theoretical foundations for rigid manipulators, their direct application to DCRs remains limited by time-varying kinematics and underactuated deformation dynamics. This paper proposes Jacobian Exploratory Dual-Phase RL (JEDP-RL), a framework that decomposes planning into phased Jacobian estimation and policy execution. During each training step, we first perform small-scale local exploratory actions to estimate the deformation Jacobian matrix, then augment the state representation with Jacobian features to restore approximate Markovianity. Extensive SOFA surgical dynamic simulations demonstrate JEDP-RL's three key advantages over proximal policy optimization (PPO) baselines: 1) Convergence speed: 3.2x faster policy convergence, 2) Navigation efficiency: requires 25% fewer steps to reach the target, and 3) Generalization ability: achieve 92% success rate under material property variations and achieve 83% (33% higher than PPO) success rate in the unseen tissue environment.

cs.RO↗

A Foundation Model for DAS Signal Recognition and Visual Prompt Tuning of the Pre-trained Model for Downstream Tasks

Distributed Acoustic Sensing (DAS) technology finds growing applications across various domains. However, data distribution disparities due to heterogeneous sensing environments pose challenges for data-driven artificial intelligence (AI) models, limiting cross-domain generalization and facing a shortage of labeled training data. To address these issues, this study proposes a foundational model for DAS signal recognition based on a Masked Autoencoder, named MAEPD. The MAEPD model is pretrained on a dataset of 635,860 samples, encompassing DAS gait spatiotemporal signals, 2D GASF images for perimeter security, 2D time-frequency images for pipeline leakage, and open-dataset signals including whale vocalizations and seismic activities, using a self-supervised mask reconstruction task to capture deep semantic features of DAS signals. Visual Prompt Tuning (VPT) is employed for downstream recognition tasks. This method freezes the pretrained backbone parameters and fine-tunes only a small set of learnable visual prompt vectors inserted into the Transformer encoder layers. Experiments on the NVIDIA GeForce RTX 4080 Super platform validate MAEPD using indoor gait recognition as a downstream task. The VPT-Deep approach achieves a classification accuracy of 96.94% with just 0.322% of parameters fine-tuned, surpassing the traditional Full Fine Tuning (FFT) method by 0.61% and reducing training time by 45%. The model also exhibits robust performance in pipeline leakage detection, confirming the generality, efficiency, and scalability of MAEPD as a foundational model. This approach offers a novel paradigm for addressing the limited generalization of signal recognition models in the DAS domain.

cs.CV↗

Learning to Perform Low-Contact Autonomous Nasotracheal Intubation by Recurrent Action-Confidence Chunking with Transformer

Nasotracheal intubation (NTI) is critical for establishing artificial airways in clinical anesthesia and critical care. Current manual methods face significant challenges, including cross-infection, especially during respiratory infection care, and insufficient control of endoluminal contact forces, increasing the risk of mucosal injuries. While existing studies have focused on automated endoscopic insertion, the automation of NTI remains unexplored despite its unique challenges: Nasotracheal tubes exhibit greater diameter and rigidity than standard endoscopes, substantially increasing insertion complexity and patient risks. We propose a novel autonomous NTI system with two key components to address these challenges. First, an autonomous NTI system is developed, incorporating a prosthesis embedded with force sensors, allowing for safety assessment and data filtering. Then, the Recurrent Action-Confidence Chunking with Transformer (RACCT) model is developed to handle complex tube-tissue interactions and partial visual observations. Experimental results demonstrate that the RACCT model outperforms the ACT model in all aspects and achieves a 66% reduction in average peak insertion force compared to manual operations while maintaining equivalent success rates. This validates the system's potential for reducing infection risks and improving procedural safety.

cs.RO↗

Exploring Stiffness Gradient Effects in Magnetically Induced Metamorphic Materials via Continuum Simulation and Validation

Magnetic soft continuum robots are capable of bending with remote control in confined space environments, and they have been applied in various bioengineering contexts. As one type of ferromagnetic soft continuums, the Magnetically Induced Metamorphic Materials (MIMMs)-based continuum (MC) exhibits similar bending behaviors. Based on the characteristics of its base material, MC is flexible in modifying unit stiffness and convenient in molding fabrication. However, recent studies on magnetic continuum robots have primarily focused on one or two design parameters, limiting the development of a comprehensive magnetic continuum bending model. In this work, we constructed graded-stiffness MCs (GMCs) and developed a numerical model for GMCs' bending performance, incorporating four key parameters that determine their performance. The simulated bending results were validated with real bending experiments in four different categories: varying magnetic field, cross-section, unit stiffness, and unit length. The graded-stiffness design strategy applied to GMCs prevents sharp bending at the fixed end and results in a more circular curvature. We also trained an expansion model for GMCs' bending performance that is highly efficient and accurate compared to the simulation process. An extensive library of bending prediction for GMCs was built using the trained model.

cs.RO↗

EndoControlMag: Robust Endoscopic Vascular Motion Magnification with Periodic Reference Resetting and Hierarchical Tissue-aware Dual-Mask Control

Visualizing subtle vascular motions in endoscopic surgery is crucial for surgical precision and decision-making, yet remains challenging due to the complex and dynamic nature of surgical scenes. To address this, we introduce EndoControlMag, a training-free, Lagrangian-based framework with mask-conditioned vascular motion magnification tailored to endoscopic environments. Our approach features two key modules: a Periodic Reference Resetting (PRR) scheme that divides videos into short overlapping clips with dynamically updated reference frames to prevent error accumulation while maintaining temporal coherence, and a Hierarchical Tissue-aware Magnification (HTM) framework with dual-mode mask dilation. HTM first tracks vessel cores using a pretrained visual tracking model to maintain accurate localization despite occlusions and view changes. It then applies one of two adaptive softening strategies to surrounding tissues: motion-based softening that modulates magnification strength proportional to observed tissue displacement, or distance-based exponential decay that simulates biomechanical force attenuation. This dual-mode approach accommodates diverse surgical scenarios-motion-based softening excels with complex tissue deformations while distance-based softening provides stability during unreliable optical flow conditions. We evaluate EndoControlMag on our EndoVMM24 dataset spanning four different surgery types and various challenging scenarios, including occlusions, instrument disturbance, view changes, and vessel deformations. Quantitative metrics, visual assessments, and expert surgeon evaluations demonstrate that EndoControlMag significantly outperforms existing methods in both magnification accuracy and visual quality while maintaining robustness across challenging surgical conditions. The code, dataset, and video results are available at https://szupc.github.io/EndoControlMag/.

eess.IV↗

BleedOrigin: Dynamic Bleeding Source Localization in Endoscopic Submucosal Dissection via Dual-Stage Detection and Tracking

Intraoperative bleeding during Endoscopic Submucosal Dissection (ESD) poses significant risks, demanding precise, real-time localization and continuous monitoring of the bleeding source for effective hemostatic intervention. In particular, endoscopists have to repeatedly flush to clear blood, allowing only milliseconds to identify bleeding sources, an inefficient process that prolongs operations and elevates patient risks. However, current Artificial Intelligence (AI) methods primarily focus on bleeding region segmentation, overlooking the critical need for accurate bleeding source detection and temporal tracking in the challenging ESD environment, which is marked by frequent visual obstructions and dynamic scene changes. This gap is widened by the lack of specialized datasets, hindering the development of robust AI-assisted guidance systems. To address these challenges, we introduce BleedOrigin-Bench, the first comprehensive ESD bleeding source dataset, featuring 1,771 expert-annotated bleeding sources across 106,222 frames from 44 procedures, supplemented with 39,755 pseudo-labeled frames. This benchmark covers 8 anatomical sites and 6 challenging clinical scenarios. We also present BleedOrigin-Net, a novel dual-stage detection-tracking framework for the bleeding source localization in ESD procedures, addressing the complete workflow from bleeding onset detection to continuous spatial tracking. We compare with widely-used object detection models (YOLOv11/v12), multimodal large language models, and point tracking methods. Extensive evaluation demonstrates state-of-the-art performance, achieving 96.85% frame-level accuracy ($\pm\leq8$ frames) for bleeding onset detection, 70.24% pixel-level accuracy ($\leq100$ px) for initial source detection, and 96.11% pixel-level accuracy ($\leq100$ px) for point tracking.

cs.CV↗

Recognizing Surgical Phases Anywhere: Few-Shot Test-time Adaptation and Task-graph Guided Refinement

The complexity and diversity of surgical workflows, driven by heterogeneous operating room settings, institutional protocols, and anatomical variability, present a significant challenge in developing generalizable models for cross-institutional and cross-procedural surgical understanding. While recent surgical foundation models pretrained on large-scale vision-language data offer promising transferability, their zero-shot performance remains constrained by domain shifts, limiting their utility in unseen surgical environments. To address this, we introduce Surgical Phase Anywhere (SPA), a lightweight framework for versatile surgical workflow understanding that adapts foundation models to institutional settings with minimal annotation. SPA leverages few-shot spatial adaptation to align multi-modal embeddings with institution-specific surgical scenes and phases. It also ensures temporal consistency through diffusion modeling, which encodes task-graph priors derived from institutional procedure protocols. Finally, SPA employs dynamic test-time adaptation, exploiting the mutual agreement between multi-modal phase prediction streams to adapt the model to a given test video in a self-supervised manner, enhancing the reliability under test-time distribution shifts. SPA is a lightweight adaptation framework, allowing hospitals to rapidly customize phase recognition models by defining phases in natural language text, annotating a few images with the phase labels, and providing a task graph defining phase transitions. The experimental results show that the SPA framework achieves state-of-the-art performance in few-shot surgical phase recognition across multiple institutions and procedures, even outperforming full-shot models with 32-shot labeled data. Code is available at https://github.com/CAMMA-public/SPA

cs.CV↗

Geo-RepNet: Geometry-Aware Representation Learning for Surgical Phase Recognition in Endoscopic Submucosal Dissection

Surgical phase recognition plays a critical role in developing intelligent assistance systems for minimally invasive procedures such as Endoscopic Submucosal Dissection (ESD). However, the high visual similarity across different phases and the lack of structural cues in RGB images pose significant challenges. Depth information offers valuable geometric cues that can complement appearance features by providing insights into spatial relationships and anatomical structures. In this paper, we pioneer the use of depth information for surgical phase recognition and propose Geo-RepNet, a geometry-aware convolutional framework that integrates RGB image and depth information to enhance recognition performance in complex surgical scenes. Built upon a re-parameterizable RepVGG backbone, Geo-RepNet incorporates the Depth-Guided Geometric Prior Generation (DGPG) module that extracts geometry priors from raw depth maps, and the Geometry-Enhanced Multi-scale Attention (GEMA) to inject spatial guidance through geometry-aware cross-attention and efficient multi-scale aggregation. To evaluate the effectiveness of our approach, we construct a nine-phase ESD dataset with dense frame-level annotations from real-world ESD videos. Extensive experiments on the proposed dataset demonstrate that Geo-RepNet achieves state-of-the-art performance while maintaining robustness and high computational efficiency under complex and low-texture surgical environments.

cs.CV↗