arXiv ScienceSearch

arXiv subjects

Hardy Simgen

Publications and source records attributed to Hardy Simgen.

9 recordsLinked to original sources

Application of surface coating for radon mitigation in rare-event searches

Rare-event searches offer a powerful avenue for investigating some of the most fundamental questions in modern physics, most prominently the particle nature of dark matter and the possible Majorana nature of the neutrino. Often, their dominant source of background comes from the radioactive noble gas radon emanating from materials. We report on a novel strategy to mitigate this background by the application of coating layers. A method for electroplating of copper was developed that showed a thousandfold reduction of the $^{222}$Rn emanation rate from a $^{226}$Ra-implanted stainless steel sample.

physics.ins-det

Improved and automated krypton assay for low-background xenon detectors with Auto-RGMS

Ultra-sensitive quantification of trace radioactive krypton-85 is essential for low-background experiments, particularly for next-generation searches of galactic dark matter and neutrino physics using xenon-based time projection chambers (TPCs). While the rare gas mass spectrometer (RGMS) represents the current state-of-the-art for krypton detection in the field, we are developing a fully automated system (Auto-RGMS) to overcome the limitations of its manual operation. Auto-RGMS incorporates a robust control system for rapid measurements and minimized systematic uncertainties. A primary goal is to reach detection limits in the low parts-per-quadrillion (ppq) range for natural krypton by improving the chromatography stage to enhance the separation of krypton from xenon. Investigations into various adsorbent materials identified two candidates. HayeSep Q offers a 12-fold improvement in chromatographic resolution for xenon/krypton separation compared to the previously used adsorbent. Alternatively, HayeSep D provides a more limited improvement in resolution while allowing a higher measurement frequency because of its moderate retention-induced contamination after each measurement. By automating krypton assays and achieving ppq sensitivity, Auto-RGMS will be an indispensable tool for next-generation detectors, maximizing their scientific potential.

physics.ins-det

Characterization of a $^{220}$Rn source for low-energy electronic recoil calibration of the XENONnT detector

Low-background liquid xenon detectors are utilized in the investigation of rare events, including dark matter and neutrinoless double beta decay. For their calibration, gaseous $^{220}$Rn can be used. After being introduced into the xenon, its progeny isotope $^{212}$Pb induces homogeneously distributed, low-energy ($<30$ keV) electronic recoil interactions. We report on the characterization of such a source for use in the XENONnT experiment. It consists of four commercially available $^{228}$Th sources with an activity of 55 kBq. These sources provide a high $^{220}$Rn emanation rate of about 8 kBq. We find no indication for the release of the long-lived $^{228}$Th above 1.7 mBq. Though an unexpected $^{222}$Rn emanation rate of about 3.6 mBq is observed, this source is still in line with the requirements for the XENONnT experiment.

physics.ins-det

Production and characterization of a $^{222}$Rn-emanating stainless steel source

Precise radon measurements are a requirement for various applications, ranging from radiation protection over environmental studies to material screening campaigns for rare-event searches. All of them ultimately depend on the availability of calibration sources with a known and stable radon emanation rate. A new approach to produce clean and dry radon sources by implantation of $^{226}$Ra ions into stainless steel has been investigated. In a proof of principle study, two stainless steel plates have been implanted in collaboration with the ISOLDE facility located at CERN. We present results from a complete characterization of the sources. Each sample provides a radon emanation rate of about 2 Bq, which has been measured using electrostatic radon monitors as well as miniaturized proportional counters. Additional measurements using HPGe and alpha spectrometry as well as measurements of the radon emanation rate at low temperatures were carried out.

physics.ins-det

Modeling of GERDA Phase II data

The GERmanium Detector Array (GERDA) experiment at the Gran Sasso underground laboratory (LNGS) of INFN is searching for neutrinoless double-beta ($0\nu\beta\beta$) decay of $^{76}$Ge. The technological challenge of GERDA is to operate in a "background-free" regime in the region of interest (ROI) after analysis cuts for the full 100$\,$kg$\cdot$yr target exposure of the experiment. A careful modeling and decomposition of the full-range energy spectrum is essential to predict the shape and composition of events in the ROI around $Q_{\beta\beta}$ for the $0\nu\beta\beta$ search, to extract a precise measurement of the half-life of the double-beta decay mode with neutrinos ($2\nu\beta\beta$) and in order to identify the location of residual impurities. The latter will permit future experiments to build strategies in order to further lower the background and achieve even better sensitivities. In this article the background decomposition prior to analysis cuts is presented for GERDA Phase II. The background model fit yields a flat spectrum in the ROI with a background index (BI) of $16.04^{+0.78}_{-0.85} \cdot 10^{-3}\,$cts/(kg$\cdot$keV$\cdot$yr) for the enriched BEGe data set and $14.68^{+0.47}_{-0.52} \cdot 10^{-3}\,$cts/(kg$\cdot$keV$\cdot$yr) for the enriched coaxial data set. These values are similar to the one of Gerda Phase I despite a much larger number of detectors and hence radioactive hardware components.

nucl-ex

A Rn-220 source for the calibration of low-background experiments

We characterize two 40 kBq sources of electrodeposited Th-228 for use in low-background experiments. The sources efficiently emanate Rn-220, a noble gas that can diffuse in a detector volume. Rn-220 and its daughter isotopes produce alpha, beta, and gamma-radiation, which may used to calibrate a variety of detector responses and features, before decaying completely in only a few days. We perform various tests to place limits on the release of other long-lived isotopes. In particular, we find an emanation of <0.008 atoms/min/kBq (90% CL) for Th-228 and 1.53 atoms/min/kBq for Ra-224. The sources lend themselves in particular to the calibration of detectors employing liquid noble elements such as argon and xenon. With the source mounted in a noble gas system, we demonstrate that filters are highly efficient in reducing the activity of these longer-lived isotopes further. We thus confirm the suitability of these sources even for use in next-generation experiments, such as XENON1T/XENONnT, LZ, and nEXO.

physics.ins-det

GIOVE - A New Detector Setup for High Sensitivity Germanium Spectroscopy At Shallow Depth

We report on the development and construction of the high-purity germanium spectrometer setup GIOVE (Germanium Inner Outer Veto), recently built and now operated at the shallow underground laboratory of the Max-Planck-Institut f\"ur Kernphysik, Heidelberg. Particular attention was paid to the design of a novel passive and active shield, aiming at efficient rejection of environmental and muon induced radiation backgrounds. The achieved sensitivity level of <100 {\mu}Bq/kg for primordial radionuclides from U and Th in typical {\gamma} ray sample screening measurements is unique among instruments located at comparably shallow depths and can compete with instruments at far deeper underground sites.

astro-ph.IM

Krypton assay in xenon at the ppq level using a gas chromatographic system and mass spectrometer

We have developed a new method to measure krypton traces in xenon at unprecedented low concentrations. This is a mandatory task for many near-future low-background particle physics detectors. Our system separates krypton from xenon using cryogenic gas chromatography. The amount of krypton is then quantified using a mass spectrometer. We demonstrate that the system has achieved a detection limit of 8 ppq (parts per quadrillion) and present results of distilled xenon with krypton concentrations below 1 ppt.

physics.ins-det

Detection of $^{133}$Xe from the Fukushima nuclear power plant in the upper troposphere above Germany

After the accident in the Japanese Fukushima Dai-ichi nuclear power plant in March 2011 large amounts of radioactivity were released and distributed in the atmosphere. Among them were also radioactive noble gas isotopes which can be used as tracers to test global atmospheric circulation models. This work presents unique measurements of the radionuclide $^{133}$Xe from Fukushima in the upper troposphere above Germany. The measurements involve air sampling in a research jet aircraft followed by chromatographic xenon extraction and ultra-low background gas counting with miniaturized proportional counters. With this technique a detection limit of the order of 100 $^{133}$Xe atoms in litre-scale air samples (corresponding to about 100 mBq/m$^3$) is achievable. Our results provide proof that the $^{133}$Xe-rich ground level air layer from Fukushima was lifted up to the tropopause and distributed hemispherically. Moreover, comparisons with ground level air measurements indicate that the arrival of the radioactive plume at high altitude over Germany occurred several days before the ground level plume.

physics.ins-det