arXiv Science⌕ Search

arXiv subjects

Haoyan Ding

Publications and source records attributed to Haoyan Ding.

3 recordsLinked to original sources

MammoSeek: A Mammography Agent with selective zooming for grounded reports

Radiologists read a screening mammogram by first forming a global impression of the four views and then selectively magnifying suspicious regions before assigning a BI-RADS assessment. MLLMs, in contrast, see the whole image at a fixed, reduced resolution, which makes sub-millimeter calcifications invisible, and they perform close to chance on mammography. Therefore, we present MammoSeek, a mammography agent that reproduces this reading process. After forming an impression of each breast, the agent performs selective zooming: it decides by itself which detector candidates deserve a closer look and inspects only those on full-resolution views. Guided by a BI-RADS assessment skill, it then assigns a category and generates a localized, lexicon-structured report for each breast; its assessment is combined with image-model scores in a decision layer to decide recall. On an internal (EMBED) and an external (VinDr-Mammo) dataset, \ours reaches exam-level AUCs of 0.824 and 0.818, far above other MLLMs, mammography agent and CNN classifiers. Selective zooming also outperforms both no zooming and forced zooming in localization, structured-report F1 and recall decisions at low cost.

cs.CV↗

FD-AA: A Lightweight Focal-Diffuse And Attenuation-Aware Head for Incidental Abdominal Abnormality Detection in Chest CT

Routine chest CT captures upper-abdominal structures that may contain clinically relevant incidental abnormalities. Detecting these findings requires feature extraction from organs with different spatial extents and attenuation patterns. We propose FD-AA, a lightweight organ-aware classification head adaptable for frozen 3-D CT encoders. Within each organ, an attenuation-aware module preserves sparse focal evidence, while masked generalized-mean pooling captures diffuse anomaly patterns. In seven abdominal organs, FD-AA with Pillar-0 achieved state-of-the-art (SOTA) performance in both the CT-RATE test set (AUC = 0.798) and the external RAD-ChestCT dataset (AUC = 0.713). More specifically, FD-AA improved macro AUC/AP from 0.763/0.346 to 0.798/0.405 over direct classification using frozen Pillar-0 only (p = 0.034/0.016). Such performance gain generalizes across multiple frozen encoders (AUC improvement on MedicalNet +9.8%, CT-CLIP +14.7%, ResNet +3.7%), demonstrating the effectiveness of FD-AA across different feature representations. These results support the effectiveness of integrating focal-diffuse aggregation with explicit HU evidence for incidental abdominal abnormality detection.

cs.CV↗

Instance-Guided Report Anchoring for Text-Free 3D Abnormality Segmentation in Chest CT

Accurate 3D abnormality segmentation in chest CT requires dense spatial supervision, but obtaining expert voxel-level labels is costly. Radiology reports, however, are routinely generated during clinical interpretation and contain instance-specific descriptions that can provide additional guidance without new dense annotation. Existing vision-language grounding methods typically require report-derived findings at inference, making localization dependent on paired text and limiting each forward pass to a queried finding. We propose Instance-Guided Report Anchoring (IGRA), a model-agnostic module that preserves the correspondence between each annotated abnormality instance and the report finding that describes it. IGRA pools each instance representation and anchors it to the corresponding finding embedding during training; all text-related components are discarded at inference. We further reformulate free-text grounding on ReXGroundingCT as multi-label volumetric segmentation by merging same-category instances, allowing all abnormality categories to be predicted in one image-only forward pass. IGRA improves Dice by 22.5% over the strongest image-only baseline (30.93 vs. 25.25) and is comparable to VoxTell on the single-finding subset (30.29 vs. 30.43). Applied unchanged to four standard 3D segmentation backbones, IGRA improves Dice and hit rate across all architectures. Zero-shot evaluation on LIDC-IDRI, PleThora, and a private in-house dataset further shows consistent gains over image-only baselines.

cs.CV↗