arXiv Science⌕ Search

arXiv subjects

Haoxian Liu

Publications and source records attributed to Haoxian Liu.

9 recordsLinked to original sources

Isthmus: Bridging Supervision Islands Restores Uncertainty and Stability in One-Step Flows

One-step flow maps are increasingly used as posterior samplers, where the point of sampling is the uncertainty that the samples carry. We find that the one-step sampler loses this uncertainty and becomes less stable. Compared with multi-step samples of the same network, its samples lose variance and decorrelate. Supervising the one-step jump directly makes this worse; the samples collapse further toward the conditional mean and break down when training is extended. We trace both failures to the locations where training places its pairs of start and end times. Only pairs on the diagonal of the time triangle receive targets from data, and the pair used for one-step sampling is either left unsupervised or supervised on an island, a set of pairs that the self-consistency identity does not connect to the diagonal, where the objective neither determines the one-step map nor anchors its training. We bridge the island with an isthmus, which places 5% of the training pairs along the whole edge of the triangle that joins the one-step pair to the diagonal. The error of the one-step map is then bounded by the self-consistency residual along this edge. With the network, the loss and the inference code unchanged and at no added cost, the isthmus improves one-step sampling across several flow-map objectives, in MRI reconstruction, face inpainting, and unconditional generation on CIFAR-10 and ImageNet 32x32. On brain MRI, it restores one-step calibration to 0.96 and the correlation with multi-step samples to 0.93; both vary far less across seeds, and the agreement holds when training is extended to three times its length.

cs.CV↗

FreeBrush: Motor Signals-Based Toothbrushing Monitoring System for Electric Toothbrushes

Oral health is vital for overall well-being, yet many users brush different tooth surfaces for insufficient or excessive durations. Toothbrushing monitoring systems can help improve brushing habits by reminding users of under-brushed and over-brushed surfaces, but existing approaches often rely on external sensors, increasing cost and reducing practicality. We observe that the intrinsic motor signals of electric toothbrushes can reflect the brushing surfaces and durations. When brushing different tooth surfaces, the brush head experiences different constraints from the surrounding oral cavity, changing the motor's driving currents and position feedback. Based on this observation, we propose FreeBrush, a toothbrushing monitoring system that uses the intrinsic motor signals of electric toothbrushes to recognize brushed tooth surfaces and estimate brushing durations without any external sensors. We prototype the system on a commercial off-the-shelf electric toothbrush and conduct a comprehensive evaluation with 18 participants. FreeBrush achieves 92.8% accuracy for 16-surface recognition and 92.0% accuracy for brushing duration estimation. The system further shows robustness across different toothpastes, brush heads, vibration modes, usage scenarios, and long-term use, and is capable of running on edge devices. By recognizing brushed tooth surfaces and estimating the brushing duration, FreeBrush can help users identify under-brushed and over-brushed surfaces and build balanced brushing habits.

cs.HC↗

Evaluating Scaffolding-Oriented Multi-Agent Large Language Model System for Clinical Interview Training

Clinical education must prepare medical students to conduct safe and coherent patient interviews under conditions of uncertainty. Traditional standardized patient (SP) training is resource-intensive and difficult to scale. We developed a scaffolding-oriented multi-agent Large Language Model (LLM) AI Standardized Patient (AI-SP) training platform1. The system includes a patient agent for simulated dialog, a tutor agent providing Socratic prompts without disclosing diagnostic information, and a turn-level evaluator agent that monitors clinical progress without revealing summative scores. In a randomized controlled study (N = 100 medical students), participants were assigned to either a multi-agent (MA) scaffolding condition or a control condition. All students completed two learning sessions under their assigned condition followed by an examination conducted in a patient only environment. Performance was assessed using a standardized Objective Structured Clinical Examination (OSCE) based rubric. While no significant difference was observed in final diagnostic accuracy between groups, the multi-agent AI standardized patient system improved final examination scores compared to the control group utilizing structured progressive information disclosure; the most substantial and consistent improvements were observed in communication, the expression of empathy, and specific history-taking behaviors. These findings suggest that specialized LLM agents enhance the process quality of simulated clinical interviews without artificially inflating examination outcomes. To support future research, we release a multi-expert annotated dataset comprising transcripts, checklist annotations, turn-level evaluations, and OSCE-aligned scoring outcomes. This resource aims to facilitate the development of pedagogically grounded AI-SP systems and advance research on AI-supported clinical reasoning training.

cs.MA↗

Forecasting Return Time of Extreme Precipitation by Large Deviation Theory

Forecasting extreme precipitation is essential yet challenging due to its rarity and complexity. We develop a large deviation framework to estimate the return times of extreme precipitation events. We first find that the Landau distribution, originally introduced in plasma physics, accurately captures extreme precipitation at approximately 93% of global locations, outperforming conventional extreme value distributions with 76% matched locations under the same accuracy criterion. Enriching rare event samples by the fitted Landau distribution, we obtain more accurate estimates of large deviation rate functions and return times, enabling forecasts beyond historically observed precipitation intensities. Mapping historical return times to future projections from the Coupled Model Intercomparison Project Phase 6 (CMIP6), we show that return time curves under different emission scenarios collapse onto a unified relation, revealing a sharply increased lifetime exposure to extreme precipitation for 21st-century birth cohorts under most future emission scenarios.

cond-mat.stat-mech↗

WearBCI Dataset: Understanding and Benchmarking Real-World Wearable Brain-Computer Interfaces Signals

Brain-computer interfaces (BCIs) have opened new platforms for human-computer interaction, medical diagnostics, and neurorehabilitation. Wearable BCI systems, which typically employ non-invasive electrodes for portable monitoring, hold great promise for real-world applications, but also face significant challenges of signal quality degradation caused by motion artifacts and environmental interferences. Most existing wearable BCI datasets are collected under stationary or controlled lab settings, limiting their utility for evaluating performance under body movement. To bridge this gap, we introduce WearBCI, the first dataset that comprehensively evaluates wearable BCI signals under different motion dynamics with synchronized multimodal recordings (EEG, IMU, and egocentric video), and systematic benchmark evaluations for studying impacts of motion artifact. Specifically, we collect data from 36 participants across different motion dynamics, including body movements, walking, and navigation. This dataset includes synchronized electroencephalography (EEG), inertial measurement unit (IMU) data, and egocentric video recordings. We analyze the collected wearable EEG signals to understand the impact of motion artifacts across different conditions, and benchmark representative EEG signal enhancement techniques on our dataset. Furthermore, we explore two new case studies: cross-modal EEG signal enhancement and multi-dimension human behavior understanding. These findings offer valuable insights into real-world wearable BCI deployment and new applications.

cs.HC↗

MoViD: View-Invariant 3D Human Pose Estimation via Motion-View Disentanglement

3D human pose estimation is a key enabling technology for applications such as healthcare monitoring, human-robot collaboration, and immersive gaming, but real-world deployment remains challenged by viewpoint variations. Existing methods struggle to generalize to unseen camera viewpoints, require large amounts of training data, and suffer from high inference latency. We propose MoViD, a viewpoint-invariant 3D human pose estimation framework that disentangles viewpoint information from motion features. The key idea is to extract viewpoint information from intermediate pose features and leverage it to enhance both the robustness and efficiency of pose estimation. MoViD introduces a view estimator that models key joint relationships to predict viewpoint information, and an orthogonal projection module to disentangle motion and view features, further enhanced through physics-grounded contrastive alignment across views. For real-time edge deployment, MoViD employs a frame-by-frame inference pipeline with a view-aware strategy that adaptively activates flip refinement based on the estimated viewpoint. Evaluations on nine public datasets and newly collected multiview UAV and gait analysis datasets show that MoViD reduces pose estimation error by over 24.2\% compared to state-of-the-art methods, maintains robust performance under severe occlusions with 60\% less training data, and achieves real-time inference at 15 FPS on NVIDIA edge devices.

cs.CV↗

Multivariate Gaussian Representation Learning for Medical Action Evaluation

Fine-grained action evaluation in medical vision faces unique challenges due to the unavailability of comprehensive datasets, stringent precision requirements, and insufficient spatiotemporal dynamic modeling of very rapid actions. To support development and evaluation, we introduce CPREval-6k, a multi-view, multi-label medical action benchmark containing 6,372 expert-annotated videos with 22 clinical labels. Using this dataset, we present GaussMedAct, a multivariate Gaussian encoding framework, to advance medical motion analysis through adaptive spatiotemporal representation learning. Multivariate Gaussian Representation projects the joint motions to a temporally scaled multi-dimensional space, and decomposes actions into adaptive 3D Gaussians that serve as tokens. These tokens preserve motion semantics through anisotropic covariance modeling while maintaining robustness to spatiotemporal noise. Hybrid Spatial Encoding, employing a Cartesian and Vector dual-stream strategy, effectively utilizes skeletal information in the form of joint and bone features. The proposed method achieves 92.1% Top-1 accuracy with real-time inference on the benchmark, outperforming baseline by +5.9% accuracy with only 10% FLOPs. Cross-dataset experiments confirm the superiority of our method in robustness.

cs.CV↗

Atrial Fibrillation Detection System via Acoustic Sensing for Mobile Phones

Atrial fibrillation (AF) is characterized by irregular electrical impulses originating in the atria, which can lead to severe complications and even death. Due to the intermittent nature of the AF, early and timely monitoring of AF is critical for patients to prevent further exacerbation of the condition. Although ambulatory ECG Holter monitors provide accurate monitoring, the high cost of these devices hinders their wider adoption. Current mobile-based AF detection systems offer a portable solution, however, these systems have various applicability issues such as being easily affected by environmental factors and requiring significant user effort. To overcome the above limitations, we present MobileAF, a novel smartphone-based AF detection system using speakers and microphones. In order to capture minute cardiac activities, we propose a multi-channel pulse wave probing method. In addition, we enhance the signal quality by introducing a three-stage pulse wave purification pipeline. What's more, a ResNet-based network model is built to implement accurate and reliable AF detection. We collect data from 23 participants utilizing our data collection application on the smartphone. Extensive experimental results demonstrate the superior performance of our system, with 97.9% accuracy, 96.8% precision, 97.2% recall, 98.3% specificity, and 97.0% F1 score.

cs.SD↗

AcousAF: Acoustic Sensing-Based Atrial Fibrillation Detection System for Mobile Phones

Atrial fibrillation (AF) is characterized by irregular electrical impulses originating in the atria, which can lead to severe complications and even death. Due to the intermittent nature of the AF, early and timely monitoring of AF is critical for patients to prevent further exacerbation of the condition. Although ambulatory ECG Holter monitors provide accurate monitoring, the high cost of these devices hinders their wider adoption. Current mobile-based AF detection systems offer a portable solution. However, these systems have various applicability issues, such as being easily affected by environmental factors and requiring significant user effort. To overcome the above limitations, we present AcousAF, a novel AF detection system based on acoustic sensors of smartphones. Particularly, we explore the potential of pulse wave acquisition from the wrist using smartphone speakers and microphones. In addition, we propose a well-designed framework comprised of pulse wave probing, pulse wave extraction, and AF detection to ensure accurate and reliable AF detection. We collect data from 20 participants utilizing our custom data collection application on the smartphone. Extensive experimental results demonstrate the high performance of our system, with 92.8% accuracy, 86.9% precision, 87.4% recall, and 87.1% F1 Score.

cs.SD↗