arXiv Science⌕ Search

arXiv subjects

Haofan Wu

Publications and source records attributed to Haofan Wu.

4 recordsLinked to original sources

MedHarness: A Unified Budgeted Runtime for Reliable Medical Imaging Agents

Medical imaging agents already return answers on heterogeneous imaging surfaces, yet deployment still faces a limited verification budget where each wrong accept can harm clinical trust. When a thin check and a deeper evidence pass disagree on the same case, deciding when to stop, open more evidence, repair, or reject without a shared controller remains ill-posed. Tool-using workflows often lock a surface-specific evidence order per dataset, or a private always-open full-depth verification path; those pipelines stay costly, leave many wrong accepts, and cannot share one controller across modalities. We present MedHarness, a registered multi-surface runtime reliability layer that reformulates post-answer control as shared decision-object attachment after a proposer's initial prediction. Under Shared Decision Object, Minimum-Sufficient Verification, and Intermediate Repair, one shared policy with surface recipe adapters lets a new imaging surface join the same stop / open-evidence / repair / reject controller by recipe registration. On a 512-case live pool, MedHarness cuts wrong accepts versus a full-verification baseline by about 47% and raises accepted accuracy to 83.2% vs. 72.9% at 86.1% coverage versus full release under that baseline. On a failure-enriched multi-surface stress ranking, the same controller cuts estimated remote service calls per case by about 71% versus that baseline under a matched context-load setting. A held-out three-surface check and an alternate language-model transfer keep the same control ordering. The code is available at https://anonymous.4open.science/r/MedHarness-paper-release-A7F3/.

cs.CV↗

Focus, Align, and Diffuse: Time-Series-Aware Keyframe Diffusion for Cardiac Dynamic Synthesis from Sparse Observations

Dense cardiac dynamics are essential for assessing cardiac function, yet in practice clinicians often observe only extremely sparse measurements. However, recovering full dynamics from such sparsity is a highly ill-posed problem due to the lack of temporal cues. While auxiliary time-series signals like ECG provide physiological guidance, effectively exploiting them is challenging due to the cross-modal representation gap and phase misalignment. In this work, we present CardioFAD, a Focus--Align--Diffuse paradigm that reformulates sparse cardiac dynamic synthesis as a recoverability--alignability anchor discovery problem. Our core insight is that resolving extreme temporal ambiguity requires a compact set of anchor states that are both sufficient to recover the visual trajectory and reliable for ECG--visual alignment. We therefore learn motion-salient keyframes under two complementary principles: trajectory sufficiency, which preserves trajectory-critical intra-modal motion content, and anchor alignment, which promotes consistent inter-modal correspondence at these anchors. We implement the Focus and Align modules optimized by the two aspects. Diffuse then performs two-stage generation by first synthesizing keyframes and subsequently interpolating the remaining frames. Extensive experiments on cardiac MRI and echocardiography videos demonstrate superior visual quality, temporal coherence, and improved functional consistency under the extreme one-shot regime.

eess.IV↗

Chain of Flow: ECG-Conditioned 4D Cardiac Cine Generation from Patient-Specific Anatomical Anchor

Cardiac cine magnetic resonance imaging (MRI) is central to functional cardiac assessment, yet a full current cine sequence may not always be directly available at the point of analysis. We introduce Chain of Flow (COF), an electrocardiography (ECG)-conditioned framework that combines patient-specific MRI and current ECG for subject-specific 4D cardiac cine generation. On the UK Biobank dataset, COF achieves strong image-level fidelity and downstream function-oriented performance on a shared same-visit evaluable benchmark. Multi-slice and multi-resolution analyses indicate stable structural generation quality across the short-axis stack and heterogeneous acquisition resolutions. Controlled phase-robustness analyses across resampled input MRI phases further provide same-visit proxy support for patient-specific MRI plus current ECG when a target MRI phase is not directly observed. A cross-visit route provides exploratory serial evidence, with the clearest gains in current-facing region-of-interest readout. Disease-category functional audits, case-level volume-trajectory evidence review further delineate where the current patient-specific MRI plus ECG formulation remains stable for anatomy-aware downstream cardiac analysis. Code is available at https://anonymous.4open.science/r/COF-paper-release-C88B.

cs.CV↗

Multi-Scale Target-Aware Representation Learning for Fundus Image Enhancement

High-quality fundus images provide essential anatomical information for clinical screening and ophthalmic disease diagnosis. Yet, due to hardware limitations, operational variability, and patient compliance, fundus images often suffer from low resolution and signal-to-noise ratio. Recent years have witnessed promising progress in fundus image enhancement. However, existing works usually focus on restoring structural details or global characteristics of fundus images, lacking a unified image enhancement framework to recover comprehensive multi-scale information. Moreover, few methods pinpoint the target of image enhancement, e.g., lesions, which is crucial for medical image-based diagnosis. To address these challenges, we propose a multi-scale target-aware representation learning framework (MTRL-FIE) for efficient fundus image enhancement. Specifically, we propose a multi-scale feature encoder (MFE) that employs wavelet decomposition to embed both low-frequency structural information and high-frequency details. Next, we design a structure-preserving hierarchical decoder (SHD) to fuse multi-scale feature embeddings for real fundus image restoration. SHD integrates hierarchical fusion and group attention mechanisms to achieve adaptive feature fusion while retaining local structural smoothness. Meanwhile, a target-aware feature aggregation (TFA) module is used to enhance pathological regions and reduce artifacts. Experimental results on multiple fundus image datasets demonstrate the effectiveness and generalizability of MTRL-FIE for fundus image enhancement. Compared to state-of-the-art methods, MTRL-FIE achieves superior enhancement performance with a more lightweight architecture. Furthermore, our approach generalizes to other ophthalmic image processing tasks without supervised fine-tuning, highlighting its potential for clinical applications.

eess.IV↗