arXiv ScienceSearch

arXiv subjects

H. Tanigawa

Publications and source records attributed to H. Tanigawa.

7 recordsLinked to original sources

Silicon Vertex Detector of the Belle II Experiment

The silicon vertex detector (SVD) is installed at the heart of the Belle II experiment, taking data at the high-luminosity $B$-Factory SuperKEKB since 2019. The detector has shown a stable and above-99\% hit efficiency, with a large signal-to-noise in all sensors since the beginning of data taking. Cluster position and time resolution have been measured with 2020 and 2022 data and show excellent performance and stability. The effect of radiation damage is visible, but not affecting the performance. As the luminosity increases, higher machine backgrounds are expected and the excellent hit-time information in SVD can be exploited for background rejection. In particular, we have recently developed a novel procedure to select hits by grouping them event-by-event based on their time. This new procedure allows a significant reduction of the fake rate, while preserving the tracking efficiency, and it has therefore replaced the previous cut-based procedure. We have developed a method that uses the SVD hits to estimate the track time (previously unavailable) and the collision time. It has a similar precision to the estimate based on the drift chamber but its execution time is three orders of magnitude smaller, allowing a faster online reconstruction that is crucial in a high luminosity regime. The track time is a powerful information provided to analysis that allows, together with the above-mention grouping selection, to raise the occupancy limit above that expected at nominal luminosity, leaving room for a safety factor. Finally, in June 2022 the data taking of the Belle II experiment was stopped to install a new two-layer DEPFET detector (PXD) and upgrade components of the accelerator. The whole silicon tracker (PXD+SVD) has been extracted from Belle II, the new PXD installed, the detector closed and commissioned. We briefly describe the SVD results of this upgrade.

hep-ex

Measured and projected beam backgrounds in the Belle II experiment at the SuperKEKB collider

The Belle II experiment at the SuperKEKB electron-positron collider aims to collect an unprecedented data set of $50~{\rm ab}^{-1}$ to study $CP$-violation in the $B$-meson system and to search for Physics beyond the Standard Model. SuperKEKB is already the world's highest-luminosity collider. In order to collect the planned data set within approximately one decade, the target is to reach a peak luminosity of $\rm 6 \times 10^{35}~cm^{-2}s^{-1}$ by further increasing the beam currents and reducing the beam size at the interaction point by squeezing the betatron function down to $β^{*}_{\rm y}=\rm 0.3~mm$. To ensure detector longevity and maintain good reconstruction performance, beam backgrounds must remain well controlled. We report on current background rates in Belle II and compare these against simulation. We find that a number of recent refinements have significantly improved the background simulation accuracy. Finally, we estimate the safety margins going forward. We predict that backgrounds should remain high but acceptable until a luminosity of at least $\rm 2.8 \times 10^{35}~cm^{-2}s^{-1}$ is reached for $β^{*}_{\rm y}=\rm 0.6~mm$. At this point, the most vulnerable Belle II detectors, the Time-of-Propagation (TOP) particle identification system and the Central Drift Chamber (CDC), have predicted background hit rates from single-beam and luminosity backgrounds that add up to approximately half of the maximum acceptable rates.

hep-ex

Measurement of the cluster position resolution of the Belle II Silicon Vertex Detector

The Silicon Vertex Detector (SVD), with its four double-sided silicon strip sensor layers, is one of the two vertex sub-detectors of Belle II operating at SuperKEKB collider (KEK, Japan). Since 2019 and the start of the data taking, the SVD has demonstrated a reliable and highly efficient operation, even running in an environment with harsh beam backgrounds that are induced by the world's highest instantaneous luminosity. In order to provide the best quality track reconstruction with an efficient pattern recognition and track fit, and to correctly propagate the uncertainty on the hit's position to the track parameters, it is crucial to precisely estimate the resolution of the cluster position measurement. Several methods for estimating the position resolution directly from the data will be discussed.

physics.ins-det

Beam background expectations for Belle II at SuperKEKB

The Belle II experiment at the SuperKEKB electron-positron collider aims to collect an unprecedented data set of $\rm 50~{\rm ab}^{-1}$ to study $CP$-violation in the $B$-meson system and to search for Physics beyond the Standard Model (BSM). SuperKEKB is already the world's highest-luminosity collider. In order to collect the planned data set within approximately one decade, the target is to reach a peak luminosity of $\rm 6.3 \times 10^{35}~cm^{-2}s^{-1}$ by further increasing the beam currents and reducing the beam-size at the interaction point by squeezing the betatron function down to $β^{*}_{\rm y}=\rm 0.3~mm$. Beam backgrounds are a key challenge in this context. We estimate the expected background evolution in the next ten years and discuss potential challenges and background mitigation strategies. We find that backgrounds will remain high but acceptable until a luminosity of at least $\rm 2.8\times 10^{35}~cm^{-2}s^{-1}$ is reached at $β^{*}_{\rm y}=\rm 0.6~mm$. Beyond this luminosity, predictions are highly uncertain, owing to a planned redesign of the interaction region. Improved background estimates with reduced uncertainties for the final, maximum-luminosity operation will require completion of this redesign.

hep-ex

The Silicon Vertex Detector of the Belle II Experiment

In 2019 the Belle II experiment started data taking at the asymmetric SuperKEKB collider (KEK, Japan) operating at the Y(4S) resonance. Belle II will search for new physics beyond the Standard Model by collecting an integrated luminosity of 50~ab$^{-1}$. The silicon vertex detector (SVD), consisting of four layers of double-sided silicon strip sensors, is one of the two vertex sub-detectors. The SVD extrapolates the tracks to the inner pixel detector (PXD) with enough precision to correctly identify hits in the PXD belonging to the track. In addition the SVD has standalone tracking capability and utilizes ionization to enhance particle identification in the low momentum region. The SVD is operating reliably and with high efficiency, despite exposure to the harsh beam background of the highest peak-luminosity collider ever built. High signal-to-noise ratio and hit efficiency have been measured, as well as the spatial resolution; all these quantities show excellent stability over time. Data-simulation agreement on cluster properties has recently been improved through a careful tuning of the simulation. The precise hit-time resolution can be exploited to reject out-of-time hits induced by beam background, which will make the SVD more robust against higher levels of background. During the first three years of running, radiation damage effects on strip noise, sensor currents and depletion voltage have been observed, as well as some coupling capacitor failure due to intense radiation bursts. None of these effects cause significant degradation in the detector performance.

physics.ins-det

Reduction of threshold current density for current-driven domain wall motion by shape control

We investigated the aspect ratio (thickness/width) dependence of the threshold current density required for the current-driven domain wall (DW) motion for the Ni81Fe19 nanowires. It has been shown theoretically that the threshold current density is proportional to the product of the hard-axis magnetic anisotropy Kperp and the DW width lamda. (Phys. Rev. Lett. 92, 086601 (2004).) We show experimentally that Kperp can be controlled by the magnetic shape anisotropy in the case of the Ni81Fe19 nanowires, and that the threshold current density increases with an increase of Kperp*l. We succeeded to reduce the threshold current density by half by the shape control.

cond-mat.mtrl-sci

Effect of Joule heating in current-driven domain wall motion

It was found that high current density needed for the current-driven domain wall motion results in the Joule heating of the sample. The sample temperature, when the current-driven domain wall motion occurred, was estimated by measuring the sample resistance during the application of a pulsed-current. The sample temperature was 750 K for the threshold current density of 6.7 x 10^11 A/m2 in a 10 nm-thick Ni81Fe19 wire with a width of 240 nm. The temperature was raised to 830 K for the current density of 7.5 x 10^11 A/m2, which is very close to the Curie temperature of bulk Ni81Fe19. When the current density exceeded 7.5 x 10^11 A/m2, an appearance of a multi-domain structure in the wire was observed by magnetic force microscopy, suggesting that the sample temperature exceeded the Curie temperature.

cond-mat.mtrl-sci