2 recordsLinked to original sources

Tests on the POD-P controller of INELFE Spain-France VSC-HVDC interconnector

INELFE interconnector consists of a 2x1000 MW high voltage direct current system based on voltage source converters (VSC-HVDC) interconnecting France and Spain. INELFE VSC-HVDC link is embedded into the high voltage alternating current (HVAC) system. Electromechanical oscillations, also known as power oscillations, are a major concern worldwide. INELFE VSC-HVDC link has specific controllers to damp power oscillations by modulating active (P)- and reactive (Q)-power injections of the VSC converters (POD-P and POD-Q controllers, respectively). The Spanish and French Transmission System Operators (TSOs) carried out a join task force to - Increase the gain of POD-P controller of INELFE VSC-HVDC link. - Make it possible to use the POD-P controller together with angle difference control (ADC) of INELFE VSC-HVDC interconnector. The objective of these modifications is to improve the effectiveness of POD-P controller and, therefore, to increase its contribution to the damping of inter-area oscillations in the Continental Europe (CE) power system. Such changes require (a) extensive simulation studies and (b) extensive tests in different operation modes, in order to ensure the correct behavior of the system. This paper presents simulation studies and field tests on the POD-P controller of INELFE VSC-HVDC interconnector in different modes of operation.

eess.SY

Impact of Communication Delay and Sampling on Small-Signal Stability of IBR-rich Power Systems

The growing adoption of inverter-based resources (IBRs) has introduced unprecedented dynamics in power systems, resulting in oscillations across a broad spectrum of frequencies. Communication delay between the plant-level control and the inverter-level control in IBR plants has been recognized as one of the causes of such oscillations and a factor that impacts the system's stability. The control signals from the plant-level controller also experience sampling, with the sampled values held constant by the hold elements for the duration of the sampling period. This also has a bearing on the response of IBR plants. In this paper, we analyze the impacts of communication delay and sampling of control signals between plant-level control and inverter-level control of grid-following IBR plants on the small-signal stability of power systems. The underlying fundamentals of communication delay and sampling are revisited to explain the observed responses. Our findings emphasize the unique effects of communication delay and sampling period on the stability of IBR-rich power systems and suggest strategies to mitigate their detrimental impacts. The work also highlights the need for more accurate approaches for small-signal stability analysis of such systems.

eess.SY