Shift or curtail? How much data-center flexibility is worth depends on the host power grid

Data-center growth risks overbuilding power grid infrastructure and stranding capital. Flexible data-center operation can defer infrastructure investments, but its value depends on the flexibility mechanism and the host power grid characteristics. We classify data-center load as firm, flexible or interruptible, and embed them in capacity expansion applied to market-organized, fossil-heavy PJM and carbon-capped, centrally coordinated Korea. In PJM, the flexibility value is spatial: shifting workloads between zones reduces system cost by 6% in 2028 and 19% in 2038, avoiding 4.4 GW and 8.9 GW of gas and nuclear generation. In Korea, it is temporal: shifting load into midday solar hours makes 0.5 GW of additional solar worth building in 2028 and avoids 1.2 GW of gas and 0.3 GW of batteries in 2038. In both, realistic event-shape limits diminish the value of curtailment. The results show that flexibility procurement and its value are driven by grid characteristics and policy objectives.

physics.soc-ph

Integrating Conductor Health into Dynamic Line Rating and Unit Commitment under Wind Uncertainty

Dynamic line rating (DLR) enables greater utilization of existing transmission lines by leveraging real-time weather data. However, the elevated temperature operation (ETO) of conductors under DLR, particularly in the presence of uncertainty, is often overlooked, despite its long-term impact on conductor health. This paper addresses ETO under DLR and wind power uncertainty by 1) quantifying risk-based depreciation costs associated with ETO, 2) characterizing correlation-driven ETO risk from wind power and DLR forecast errors, and 3) proposing a Conductor Health-Aware Unit Commitment (CHA-UC) that internalizes these costs in operational decisions. CHA-UC incorporates a robust linear approximation of conductor temperature and integrates expected depreciation costs due to hourly ETO into the objective function. Case studies on the Texas 123-bus backbone test system demonstrate that the proposed CHA-UC model reduces the total cost by 0.75\% and renewable curtailment by 82\% compared to static line rating (SLR) and outperforms quantile regression forest-based methods, while conventional DLR operation without risk consideration resulted in higher costs due to excessive ETO. Further analysis shows that CHA-UC achieves safer line utilization by shifting generator commitments and endogenously adapting to uncertainty correlation, relaxing flows under risk-hedging conditions and tightening flows under risk-amplifying conditions.

eess.SY