arXiv ScienceSearch

arXiv subjects

Gary S. Collins

Publications and source records attributed to Gary S. Collins.

2 recordsLinked to original sources

Collapsibility of Performance Metrics in Clinical Predictive AI

Background: Population level assessments of predictive artificial intelligence (AI) can conceal performance disparities across subgroups. Fairness evaluations commonly rely on performance analyses across subgroups. However, some performance metrics are non-collapsible, meaning that the overall population performance value does not equal the weighted average of subgroup specific values. Objective: To examine the collapsibility properties of commonly reported performance metrics in predictive AI, with a focus on the area under the receiver operating characteristic curve (AUC, also known as c-statistic). Methods: We investigate the collapsibility of 15 performance metrics, either by expressing each metric as a linear combination of its stratum specific values or, where non-collapsible, by providing a counterexample inspired by Simpson's paradox as a formal disproof. Results: Five performance metrics (AUC, calibration intercept, calibration slope, expected calibration error, and Nagelkerke R^2) are shown to be non-collapsible, and ten (O:E ratio, logloss, Brier score, accuracy, F1-score, true positive rate, true negative rate, positive predictive value, negative predictive value, and net benefit) are shown to be collapsible. The AUC is shown to be non-collapsible because it decomposes into within- and cross-group AUC terms when subpopulations coexist, such that its overall value may fall outside the range of subgroup specific AUCs. Conclusions: Non-collapsibility of performance metrics has important consequences for reporting, model appraisal, and fairness evaluation. It can generate spurious differences between subgroup and overall performance, which may mislead fairness evaluations. Explicitly acknowledging and reporting the collapsibility properties of performance metrics improves both the interpretability and transparency of fairness assessments.

cs.LG

Learning Human Health and Diseases from 24-hour Wrist Movement

Much of human health and function unfolds beyond the clinic, through the movements of everyday life. Wrist-worn accelerometers capture these movements continuously, yet their rich signals are often reduced to a small set of predefined behavioural summary measures. Here, we present Sensori, a self-supervised foundation model that learns general-purpose health representations directly from 24 hours of raw tri-axial wrist movement. We developed and evaluated the model across four population-based cohorts from the United Kingdom, China and the United States, comprising 122,640 participants contributing 683,617 person-days of free-living recordings. Sensori condensed each day of movement into a representation that captured diverse movement behaviours, demographic characteristics, health axes and physical function. Evaluation in independent cohorts showed that these representations generalised across populations and measurement settings without retraining. When added to common clinical covariates, Sensori significantly improved prevalent disease classification for 52 of 102 eligible conditions (median delta AUROC, 0.060; range, 0.012-0.242) and incident disease risk prediction for 26 of 87 eligible conditions (median delta Uno's C-index, 0.064; range, 0.025-0.172), with the largest gains for neurological and psychiatric disorders. These findings establish 24-hour wrist movement as a rich and scalable source of health information, with the potential to support passive health monitoring and disease prediction at population scale.

cs.LG