Garry Chinn

Publications and source records attributed to Garry Chinn.

5 recordsLinked to original sources

Alkaline-Earth Rare-Earth Fluoride Nanoparticle Superlattices for Ultrafast, Radiation Stable Scintillators

Radioluminescent nanostructures provide a pathway to the fabrication of next-generation scintillators with tunability in composition, size, and morphology, and spectral and temporal properties, as well as scalable processing. Here we create a 3D millimeter-scale solid-state scintillators from SrLuF Ce3+, Pr3+ (SrLuF) core-shell nanostructures, integrating nanoscale building blocks into self-assembled macroscopic crystals. These scintillators exhibit single-digit nanosecond decay times, linear response, resistance to radiation-induced degradation, and optical emission yields within an order of magnitude of YAG Ce3+. We select a SrLuF host lattice owing to its high effective atomic number, wide band gap, and low phonon energy, which together support efficient 4f-5d radiative transitions from Ce3+ and Pr3+ activators while suppressing afterglow. We create a library of core-shell nanoscintillators with undoped SrLuF shells and cores spanning compositions from undoped SrLuF to fully doped SrCeF or SrPrF. Time-resolved and steady-state X-ray excited optical luminescence (XEOL) reveal broadband emission at 310 nm (Ce3+) and 335 nm (Pr3+) with biexponential decays in the sub-nanosecond (100-500 ps) and sub-15 ns (4-13 ns) regimes, demonstrating tunable radiative efficiency and ultrafast dynamics. Ensemble performance of the mm-scale superlattices is characterized under both continuous-wave and femtosecond high-intensity excitation, revealing high light yield, linear response, and radiation hardness under extreme irradiation of ultrafast 50fs X-ray pulses up to 5mJ per mm2 corresponding to a peak intensity of 1013 W per cm2. Together, these results establish a design framework for stable, bright, and tunable scintillation platforms with applications in precision health, space exploration and hard X-ray imaging at next-generation free-electron laser facilities.

cond-mat.mtrl-sci

Maximum Likelihood Estimation Yields Accurate Line-of-Response Assignment for Positron + Prompt Gamma Ray Events in Multiplexed PET (mPET)

For accurate disease characterization using positron emission tomography (PET), it is desirable to image multiple radiotracers in a single scan. Conventional PET methods cannot do this due to the indistinguishable annihilation photons produced by different radiotracers. One approach is to label one radiotracer with a positron+prompt-gamma ($\beta^+\!\!-\!\!\gamma$) isotope producing triple coincidences, and another with a pure positron-emitting ($\beta^+$) isotope producing double coincidences. However, $\beta^+\!\!-\!\!\gamma$ emitters present challenges in correctly identifying the two annihilation photons, or equivalently, assigning the correct line-of-response (LOR) to triple-photon coincidence events. Here, we propose a maximum likelihood estimation (MLE) framework leveraging spatial, timing, and energy information to determine the most probable LOR. Simulation studies validated the method: simulations showed over 96\% and 94\% accuracy for LOR assignment of $\beta^+\!\!-\!\!\gamma$ emitters $^{22}$Na and $^{124}$I point sources, respectively. Furthermore, simulated phantom imaging of $^{22}$Na or $^{124}$I distributions alongside a $\beta^+$ emitter demonstrated that MLE LOR assignment achieved comparable image quality -- measured by contrast recovery coefficient (CRC) and cross-talk ratio (XR) -- to benchmark methods, where the prompt gamma was identified using an energy threshold ($\geq 650$ keV) for $^{22}$Na and as the highest-energy photon for $^{124}$I.

physics.med-ph

Comparison of Deep Learning and Particle Smoother EM Methods for Estimation of Rb-82 Myocardial Perfusion PET Kinetic Parameters

Positron emission tomography (PET) enables quantification of dynamic physiological processes through time-resolved imaging. In Rb-82 myocardial perfusion PET, kinetic compartment modeling is used to estimate physiological parameters and derive myocardial blood flow. However, conventional nonlinear least squares (NLLS) estimation is sensitive to model misspecification when not all parameters can be reliably estimated and must instead be fixed or initialized using population averages, which can degrade accuracy. This work develops and evaluates two alternative kinetic analysis approaches for Rb-82 PET: a particle smoother-based Expectation-Maximization method (PSEM) and a convolutional neural network (CNN). Both methods were evaluated using simulated Rb-82 dynamic myocardial perfusion studies and compared against NLLS and a Kalman smoother-based Expectation-Maximization (KEM) algorithm across multiple frame durations and noise levels. Across 2-10 s frames, the CNN achieved the lowest relative errors for all parameters (F: 8.78-4.98%, k3: 26.05-25.50%, k4: 34.34-22.76%), significantly outperforming NLLS, KEM, and PSEM (Holm-adjusted p < 1e-15 at 1.0x noise, 2 s frames), although performance degraded under out-of-distribution input-function conditions. Overall, the CNN provided the most accurate and robust in-distribution kinetic parameter estimates across frame durations. In contrast, PSEM exhibited parameter-dependent behavior, improving k3 estimation while underperforming for F, suggesting that further methodological refinement is needed.

physics.med-ph

Quantitative Imaging of $^{55}\text{Co}$ and $^{18}\text{F}$-Labeled Tracers in a Single "Multiplexed" PET Imaging Session

In this study, we explore the use of Co-55 as a radioisotope for multiplexed PET (mPET) by utilizing its emission of a prompt gamma-ray in cascade with a positron during decay. We leverage the prompt-gamma signal to generate triple coincidences for a Co-55-labeled tracer, allowing us to distinguish it from a tracer labeled with a pure positron emitter, such as F-18. By employing triple versus double coincidence detection and signal processing methodology, we successfully separate the Co-55 signal from that of F-18. Phantom studies were conducted to establish the correlation between Co-55 double and triple coincidence counts and Co-55 activity. Additionally, we demonstrate the potential for quantifying hot spots within a warm background produced by both Co-55 and F-18 signals in a single PET scan. Finally, we showcase the ability to simultaneously image two tracers in vivo in a single PET session with mouse models of cancer.

physics.med-ph

A single-photon sampling architecture for solid-state imaging

Advances in solid-state technology have enabled the development of silicon photomultiplier sensor arrays capable of sensing individual photons. Combined with high-frequency time-to-digital converters (TDCs), this technology opens up the prospect of sensors capable of recording with high accuracy both the time and location of each detected photon. Such a capability could lead to significant improvements in imaging accuracy, especially for applications operating with low photon fluxes such as LiDAR and positron emission tomography. The demands placed on on-chip readout circuitry imposes stringent trade-offs between fill factor and spatio-temporal resolution, causing many contemporary designs to severely underutilize the technology's full potential. Concentrating on the low photon flux setting, this paper leverages results from group testing and proposes an architecture for a highly efficient readout of pixels using only a small number of TDCs, thereby also reducing both cost and power consumption. The design relies on a multiplexing technique based on binary interconnection matrices. We provide optimized instances of these matrices for various sensor parameters and give explicit upper and lower bounds on the number of TDCs required to uniquely decode a given maximum number of simultaneous photon arrivals. To illustrate the strength of the proposed architecture, we note a typical digitization result of a 120x120 photodiode sensor on a 30um x 30um pitch with a 40ps time resolution and an estimated fill factor of approximately 70%, using only 161 TDCs. The design guarantees registration and unique recovery of up to 4 simultaneous photon arrivals using a fast decoding algorithm. In a series of realistic simulations of scintillation events in clinical positron emission tomography the design was able to recover the spatio-temporal location of 98.6% of all photons that caused pixel firings.

cs.IT