arXiv ScienceSearch

arXiv subjects

G. Sheffer

Publications and source records attributed to G. Sheffer.

14 recordsLinked to original sources

Detector for measuring the $\pi^+\to e^+\nu_e$ branching fraction

The PIENU experiment at TRIUMF is aimed at a measurement of the branching ratio $R^{e/\mu}$ = ${\Gamma\big((\pi^{+} \rightarrow e^{+} \nu_{e}) + (\pi^{+} \rightarrow e^{+} \nu_{e}\gamma)\big)}/{\Gamma\big((\pi^{+} \rightarrow \mu^{+} \nu_{\mu})+(\pi^{+} \rightarrow \mu^{+} \nu_{\mu}\gamma)\big)}$ with precision $<$0.1\%. Incident pions, delivered at the rate of 60 kHz with momentum 75 MeV/c, were degraded and stopped in a plastic scintillator target. Pions and their decay product positrons were detected with plastic scintillators and tracked with multiwire proportional chambers and silicon strip detectors. The energies of the positrons were measured in a spectrometer consisting of a large NaI(T$\ell$) crystal surrounded by an array of pure CsI crystals. This paper provides a description of the PIENU experimental apparatus and its performance in pursuit of $R^{e/\mu}$.

physics.ins-det

A search for two body muon decay signals

Lepton family number violation is tested by searching for $\mu^+\to e^+X^0$ decays among the 5.8$\times 10^8$ positive muon decay events analyzed by the TWIST collaboration. Limits are set on the production of both massless and massive $X^0$ bosons. The large angular acceptance of this experiment allows limits to be placed on anisotropic $\mu^+\to e^+X^0$ decays, which can arise from interactions violating both lepton flavor and parity conservation. Branching ratio limits of order $10^{-5}$ are obtained for bosons with masses of 13 - 80 MeV/c$^2$ and with different decay asymmetries. For bosons with masses less than 13 MeV/c$^{2}$ the asymmetry dependence is much stronger and the 90% limit on the branching ratio varies up to $5.8 \times 10^{-5}$. This is the first study that explicitly evaluates the limits for anisotropic two body muon decays.

hep-ex

Precision muon decay measurements and improved constraints on the weak interaction

The TWIST Collaboration has completed its measurement of the three muon decay parameters \rho, \delta, and P_\mu\xi. This paper describes our determination of \rho, which governs the shape of the overall momentum spectrum, and \delta, which controls the momentum dependence of the parity-violating decay asymmetry. The results are \rho=0.74977\pm 0.00012(stat.)\pm 0.00023(syst.) and \delta = 0.75049\pm 0.00021(stat.)\pm 0.00027(syst.). These are consistent with the value of 3/4 given for both parameters in the standard model, and each is over a factor of 10 more precise than the measurements published prior to TWIST. Our final results on \rho, \delta, and P_\mu\xi have been incorporated into a new global analysis of all available muon decay data, resulting in improved model-independent constraints on the possible weak interactions of right-handed particles.

hep-ex

Precise measurement of parity violation in polarized muon decay

We present a new high precision measurement of parity violation in the weak interaction, using polarized muon decay. The TWIST collaboration has measured $P_\mu^\pi \xi$, where $P_\mu^\pi$ is the polarization of the muon in pion decay and $\xi$ describes the intrinsic asymmetry in muon decay. We find $P_\mu^\pi \xi = 1.00084 \pm 0.00029\,(\textrm{stat.})_{-0.00063}^{+0.00165}\,(\textrm{syst.})$, in good agreement with the standard model prediction of $P_\mu^\pi=\xi=1$. Our result is a factor of 7 more precise than the pre-TWIST value, setting new limits in left-right symmetric electroweak extensions to the standard model.

hep-ex

New Experimental Constraints for the Standard Model from Muon Decay

The TWIST Collaboration has completed a new measurement of the energy-angle spectrum of positrons from the decay of highly polarized muons. A simultaneous measurement of the muon decay parameters {\rho}, {\delta}, and (P_{\mu}){\xi} tests the Standard Model (SM) in a purely leptonic process and provides improved limits for relevant extensions to the SM. Specifically, for the generalized left-right symmetric model |(g_R/g_L){\zeta}|<0.020 and (g_L/g_R)m_2> 578 GeV/c^2, both 90% C.L.

hep-ex

Blind analysis results of the TWIST experiment

The TRIUMF Weak Interaction Symmetry Test (TWIST) experiment was designed to test the standard model at high precision in the purely leptonic decay of polarized muons. A general four-fermion interaction model is used to describe the muon decay. TWIST measures three of the four muon decay parameters of this model, $\rho$, $\delta$ and $P_{\mu}^{\pi} \xi$, from the shape of the momentum-angle spectrum. The results of this model independent approach are compared to the standard model predictions and used to constrain new physics. Our collaboration has finalized the blind analysis of the final experimental data taken in 2006 and 2007. This analysis mostly reached our goal of a precision of an order of magnitude improvement over the pre-TWIST measurements.

hep-ex

Decay of negative muons bound in $^{27}$Al

We present the first measurement of the energy spectrum up to 70 MeV of electrons from the decay of negative muons after they become bound in $^{27}$Al atoms. The data were taken with the TWIST apparatus at TRIUMF. We find a muon lifetime of (864.6 $\pm$ 1.2) ns, in agreement with earlier measurements. The asymmetry of the decay spectrum is consistent with zero, indicating that the atomic capture has completely depolarised the muons. The measured momentum spectrum is in reasonable agreement with theoretical predictions at the higher energies, but differences around the peak of the spectrum indicate the need for \oalpha radiative corrections to the calculations. The present measurement is the most precise measurement of the decay spectrum of muons bound to any nucleus.

hep-ex

A Precision Measurement of the Muon Decay Parameters $ρ$ and $δ$

The TWIST collaboration has performed new measurements of two of the parameters that describe muon decay: $ρ$, which governs the shape of the overall momentum spectrum, and $δ$, which governs the momentum dependence of the parity-violating decay asymmetry. This analysis gives the results $ρ=0.75014\pm 0.00017(\text{stat})\pm 0.00044(\text{syst})\pm 0.00011(η)$, where the last uncertainty arises from the correlation between $ρ$ and the decay parameter $η$, and $δ= 0.75067\pm 0.00030(\text{stat})\pm 0.00067(\text{syst})$. These are consistent with the value of 3/4 given for both parameters in the Standard Model of particle physics, and are a factor of two more precise than the measurements previously published by TWIST. A new global analysis of all available muon decay data incorporating these results is presented. Improved lower and upper limits on the decay parameter $P_μ^πξ$ of $0.99524 < P_μ^πξ\leq ξ< 1.00091$ at 90% confidence are determined, where $P_μ^π$ is the polarization of the muon when it is created during pion decay, and $ξ$ governs the muon decay asymmetry. These results set new model-independent constraints on the possible weak interactions of right-handed particles. Specific implications for left-right symmetric models are discussed.

hep-ex

Measurement of two-halo neutron transfer reaction p($^{11}$Li,$^{9}$Li)t at 3$A$ MeV

The p(\nuc{11}{Li},\nuc{9}{Li})t reaction has been studied for the first time at an incident energy of 3$A$ MeV delivered by the new ISAC-2 facility at TRIUMF. An active target detector MAYA, build at GANIL, was used for the measurement. The differential cross sectionshave been determined for transitions to the \nuc{9}{Li} ground andthe first excited states in a wide range of scattering angles. Multistep transfer calculations using different \nuc{11}{Li} model wave functions, shows that wave functions with strong correlations between the halo neutrons are the most successful in reproducing the observation.

nucl-ex

Time expansion chamber system for characterization of TWIST low energy muon beams

A low mass time expansion chamber (TEC) has been developed to measure distributions of position and angle of the TRIUMF low energy surface muon beam used for the TWIST experiment. The experiment is a high precision measurement of muon decay and is dominated by systematic uncertainties, including the stability, reproducibility, and characterization of the beam. The distributions measured by two TEC modules are one essential ingredient of an accurate simulation of TWIST. The uncertainties, which are extracted through comparisons of data and simulation, must be known to assess potential systematic uncertainties of the TWIST results. The design criteria, construction, alignment, calibration, and operation of the TEC system are discussed, including experiences from initial beam studies. A brief description of the use of TEC data in the TWIST simulation is also included.

physics.ins-det

Measurement of P_{mu}xi in Polarized Muon Decay

The quantity P_{mu}^{pi}xi, where xi is one of the muon decay parameters and $P_{\mu}^{\pi}$ is the degree of muon polarization in pion decay, has been measured. The value P_{mu}^{pi}xi = 1.0003 +- 0.0006 stat. +- 0.0038 syst. was obtained. This result agrees with previous measurements but is over a factor of two more precise. It also agrees with the Standard Model prediction for P_{mu}^{pi}xi and thus leads to restrictions on left-right symmetric models.

hep-ex

Measurement of the Muon Decay Parameter delta

The muon decay parameter delta has been measured by the TWIST collaboration. We find delta = 0.74964 +- 0.00066(stat.) +- 0.00112(syst.), consistent with the Standard Model value of 3/4. This result implies that the product Pmuxi of the muon polarization in pion decay, Pmu, and the muon decay parameter xi falls within the 90% confidence interval 0.9960 < Pmuxi < xi < 1.0040. It also has implications for left-right-symmetric and other extensions of the Standard Model.

hep-ex

Gas gain on single wire chambers filled with pure isobutane at low pressure

The gas gain of single-wire chambers filled with isobutane, with cell cross-section 12x12 mm and wire diameters of 15, 25, 50 and 100 $μ$m, has been measured at pressures ranging 12-92 Torr. Contrary to the experience at atmospheric pressure, at very low pressures the gas gain on thick wires is higher than that on thin wires at the same applied high voltage as was recently shown. Bigger wire diameters should be used in wire chambers operating at very low pressure if multiple scattering on wires is not an issue.

physics.ins-det

Precision planar drift chambers and cradle for the TWIST muon decay spectrometer

To measure the muon decay parameters with high accuracy, we require an array of precision drift detector layers whose relative position is known with very high accuracy. This article describes the design, construction and performance of these detectors in the TWIST (TRIUMF Weak Interaction Symmetry Test) spectrometer.

hep-ex