arXiv ScienceSearch

arXiv subjects

Felix Risch

Publications and source records attributed to Felix Risch.

2 recordsLinked to original sources

Alternative origins of polarity in compressively strained SrTiO3-RENiO3 capacitors

Since its original prediction 25 years ago, room-temperature out-of-plane ferroelectricity in compressively strained SrTiO3 remains an ongoing pursuit. In this work, we investigate the structural, electrical and electromechanical properties of highly strained epitaxial SrTiO3 capacitors with rare earth nickelate electrodes. The SrTiO3 layers experience compressive strains up to -3% and exhibit pronounced tetragonality, comparable to that of bulk PbTiO3. Variable-temperature electrical measurements and room-temperature piezoresponse force microscopy reveal butterfly-shaped capacitance-voltage hysteresis and domain-like electromechanical response typical of ferroelectric materials. However, the overall behavior is inconsistent with a stable ferroelectric state. We therefore propose an alternative mechanism for the observed polarity in our samples based on spatially inhomogeneous internal fields. Our first-principles calculations show that such fields may arise from charge discontinuities between the formally charged NdNiO3 layers and charge-neutral SrTiO3 layers.

cond-mat.mtrl-sci

Real time detection of C reactive protein in interstitial fluid using electrochemical impedance spectroscopy, towards wearable health monitoring

Traditional detection methods of C-reactive protein (CRP) inflammation biomarker, in blood are expensive, time-consuming and labor-intensive. Such existing point-of-care CRP detection devices remain invasive, since they need blood sampling (finger-pricking or venous puncture). Here, we propose an electrochemical impedance spectroscopy (EIS)-based sensor for the real-time, fast, specific, sensitive, and label-free detection of C-reactive protein in the interstitial fluid (ISF) that can be accessed with minimally invasive microneedle arrays. The sensor has the potential to be integrated in a wearable device similar with the continuous glucose monitoring, that will detect CRP in interstitial fluid in a non-invasive, inexpensive and straightforward manner. The affinity based assay was tested in both buffer and ISF-like solution. The limit of detection achieved was 0.7 ug/mL of CRP in buffer, and 0.8 ug/mL of CRP in ISF-like solution and the sensor shows excellent linearity up to 10 ug/mL. It is worth noting that the proposed sensor operates in low sample volume (down to 5 uL), and has a response time of 100 seconds.

physics.med-ph