arXiv Science⌕ Search

arXiv subjects

Faisal Mahmood

Publications and source records attributed to Faisal Mahmood.

63 records · Page 4Linked to original sources

Large dynamic range autorefraction with a low-cost diffuser wavefront sensor

Wavefront sensing with a thin diffuser has emerged as a potential low-cost alternative to a lenslet array for aberrometry. Diffuser wavefront sensors (DWS) have previously relied on tracking speckle displacement and consequently require coherent illumination. Here we show that displacement of caustic patterns can be tracked for estimating wavefront gradient, enabling the use of incoherent light sources and large dynamic-range wavefront measurements. We compare the precision of a DWS to a Shack-Hartmann wavefront sensor (SHWS) when using coherent, partially coherent, and incoherent illumination, in the application of autorefraction. We induce spherical and cylindrical errors in a model eye and use a multi-level Demon's non-rigid registration algorithm to estimate caustic displacements relative to an emmetropic model eye. When compared to spherical error measurements with the SHWS using partially coherent illumination, the DWS demonstrates a $\sim$5-fold improvement in dynamic range (-4.0 to +4.5 D vs. -22.0 to +19.5 D) with less than half the reduction in resolution (0.072 vs. 0.116 D), enabling a $\sim$3-fold increase in the number of resolvable prescriptions (118 vs. 358). In addition to being 40x lower-cost, the unique, non-periodic nature of the caustic pattern formed by a diffuser enables a larger dynamic range of aberration measurements compared to a lenslet array.

physics.optics↗

Multimodal Densenet

Humans make accurate decisions by interpreting complex data from multiple sources. Medical diagnostics, in particular, often hinge on human interpretation of multi-modal information. In order for artificial intelligence to make progress in automated, objective, and accurate diagnosis and prognosis, methods to fuse information from multiple medical imaging modalities are required. However, combining information from multiple data sources has several challenges, as current deep learning architectures lack the ability to extract useful representations from multimodal information, and often simple concatenation is used to fuse such information. In this work, we propose Multimodal DenseNet, a novel architecture for fusing multimodal data. Instead of focusing on concatenation or early and late fusion, our proposed architectures fuses information over several layers and gives the model flexibility in how it combines information from multiple sources. We apply this architecture to the challenge of polyp characterization and landmark identification in endoscopy. Features from white light images are fused with features from narrow band imaging or depth maps. This study demonstrates that Multimodal DenseNet outperforms monomodal classification as well as other multimodal fusion techniques by a significant margin on two different datasets.

cs.CV↗

Deep Adversarial Training for Multi-Organ Nuclei Segmentation in Histopathology Images

Nuclei segmentation is a fundamental task that is critical for various computational pathology applications including nuclei morphology analysis, cell type classification, and cancer grading. Conventional vision-based methods for nuclei segmentation struggle in challenging cases and deep learning approaches have proven to be more robust and generalizable. However, CNNs require large amounts of labeled histopathology data. Moreover, conventional CNN-based approaches lack structured prediction capabilities which are required to distinguish overlapping and clumped nuclei. Here, we present an approach to nuclei segmentation that overcomes these challenges by utilizing a conditional generative adversarial network (cGAN) trained with synthetic and real data. We generate a large dataset of H&E training images with perfect nuclei segmentation labels using an unpaired GAN framework. This synthetic data along with real histopathology data from six different organs are used to train a conditional GAN with spectral normalization and gradient penalty for nuclei segmentation. This adversarial regression framework enforces higher order consistency when compared to conventional CNN models. We demonstrate that this nuclei segmentation approach generalizes across different organs, sites, patients and disease states, and outperforms conventional approaches, especially in isolating individual and overlapping nuclei.

cs.CV↗

Deep Learning with Cinematic Rendering: Fine-Tuning Deep Neural Networks Using Photorealistic Medical Images

Deep learning has emerged as a powerful artificial intelligence tool to interpret medical images for a growing variety of applications. However, the paucity of medical imaging data with high-quality annotations that is necessary for training such methods ultimately limits their performance. Medical data is challenging to acquire due to privacy issues, shortage of experts available for annotation, limited representation of rare conditions and cost. This problem has previously been addressed by using synthetically generated data. However, networks trained on synthetic data often fail to generalize to real data. Cinematic rendering simulates the propagation and interaction of light passing through tissue models reconstructed from CT data, enabling the generation of photorealistic images. In this paper, we present one of the first applications of cinematic rendering in deep learning, in which we propose to fine-tune synthetic data-driven networks using cinematically rendered CT data for the task of monocular depth estimation in endoscopy. Our experiments demonstrate that: (a) Convolutional Neural Networks (CNNs) trained on synthetic data and fine-tuned on photorealistic cinematically rendered data adapt better to real medical images and demonstrate more robust performance when compared to networks with no fine-tuning, (b) these fine-tuned networks require less training data to converge to an optimal solution, and (c) fine-tuning with data from a variety of photorealistic rendering conditions of the same scene prevents the network from learning patient-specific information and aids in generalizability of the model. Our empirical evaluation demonstrates that networks fine-tuned with cinematically rendered data predict depth with 56.87% less error for rendered endoscopy images and 27.49% less error for real porcine colon endoscopy images.

cs.CV↗

Adaptive Graph-based Total Variation for Tomographic Reconstructions

Sparsity exploiting image reconstruction (SER) methods have been extensively used with Total Variation (TV) regularization for tomographic reconstructions. Local TV methods fail to preserve texture details and often create additional artefacts due to over-smoothing. Non-Local TV (NLTV) methods have been proposed as a solution to this but they either lack continuous updates due to computational constraints or limit the locality to a small region. In this paper, we propose Adaptive Graph-based TV (AGTV). The proposed method goes beyond spatial similarity between different regions of an image being reconstructed by establishing a connection between similar regions in the entire image regardless of spatial distance. As compared to NLTV the proposed method is computationally efficient and involves updating the graph prior during every iteration making the connection between similar regions stronger. Moreover, it promotes sparsity in the wavelet and graph gradient domains. Since TV is a special case of graph TV the proposed method can also be seen as a generalization of SER and TV methods.

cs.CV↗

Unsupervised Reverse Domain Adaptation for Synthetic Medical Images via Adversarial Training

To realize the full potential of deep learning for medical imaging, large annotated datasets are required for training. Such datasets are difficult to acquire because labeled medical images are not usually available due to privacy issues, lack of experts available for annotation, underrepresentation of rare conditions and poor standardization. Lack of annotated data has been addressed in conventional vision applications using synthetic images refined via unsupervised adversarial training to look like real images. However, this approach is difficult to extend to general medical imaging because of the complex and diverse set of features found in real human tissues. We propose an alternative framework that uses a reverse flow, where adversarial training is used to make real medical images more like synthetic images, and hypothesize that clinically-relevant features can be preserved via self-regularization. These domain-adapted images can then be accurately interpreted by networks trained on large datasets of synthetic medical images. We test this approach for the notoriously difficult task of depth-estimation from endoscopy. We train a depth estimator on a large dataset of synthetic images generated using an accurate forward model of an endoscope and an anatomically-realistic colon. This network predicts significantly better depths when using synthetic-like domain-adapted images compared to the real images, confirming that the clinically-relevant features of depth are preserved.

cs.CV↗

Deep Learning and Conditional Random Fields-based Depth Estimation and Topographical Reconstruction from Conventional Endoscopy

Colorectal cancer is the fourth leading cause of cancer deaths worldwide and the second leading cause in the United States. The risk of colorectal cancer can be mitigated by the identification and removal of premalignant lesions through optical colonoscopy. Unfortunately, conventional colonoscopy misses more than 20% of the polyps that should be removed, due in part to poor contrast of lesion topography. Imaging tissue topography during a colonoscopy is difficult because of the size constraints of the endoscope and the deforming mucosa. Most existing methods make geometric assumptions or incorporate a priori information, which limits accuracy and sensitivity. In this paper, we present a method that avoids these restrictions, using a joint deep convolutional neural network-conditional random field (CNN-CRF) framework. Estimated depth is used to reconstruct the topography of the surface of the colon from a single image. We train the unary and pairwise potential functions of a CRF in a CNN on synthetic data, generated by developing an endoscope camera model and rendering over 100,000 images of an anatomically-realistic colon. We validate our approach with real endoscopy images from a porcine colon, transferred to a synthetic-like domain, with ground truth from registered computed tomography measurements. The CNN-CRF approach estimates depths with a relative error of 0.152 for synthetic endoscopy images and 0.242 for real endoscopy images. We show that the estimated depth maps can be used for reconstructing the topography of the mucosa from conventional colonoscopy images. This approach can easily be integrated into existing endoscopy systems and provides a foundation for improving computer-aided detection algorithms for detection, segmentation and classification of lesions.

cs.CV↗

2D Discrete Fourier Transform with Simultaneous Edge Artifact Removal for Real-Time Applications

Two-Dimensional (2D) Discrete Fourier Transform (DFT) is a basic and computationally intensive algorithm, with a vast variety of applications. 2D images are, in general, non-periodic, but are assumed to be periodic while calculating their DFTs. This leads to cross-shaped artifacts in the frequency domain due to spectral leakage. These artifacts can have critical consequences if the DFTs are being used for further processing. In this paper we present a novel FPGA-based design to calculate high-throughput 2D DFTs with simultaneous edge artifact removal. Standard approaches for removing these artifacts using apodization functions or mirroring, either involve removing critical frequencies or a surge in computation by increasing image size. We use a periodic-plus-smooth decomposition based artifact removal algorithm optimized for FPGA implementation, while still achieving real-time ($\ge$23 frames per second) performance for a 512$\times$512 size image stream. Our optimization approach leads to a significant decrease in external memory utilization thereby avoiding memory conflicts and simplifies the design. We have tested our design on a PXIe based Xilinx Kintex 7 FPGA system communicating with a host PC which gives us the advantage to further expand the design for industrial applications.

cs.CV↗

Graph Based Sinogram Denoising for Tomographic Reconstructions

Limited data and low dose constraints are common problems in a variety of tomographic reconstruction paradigms which lead to noisy and incomplete data. Over the past few years sinogram denoising has become an essential pre-processing step for low dose Computed Tomographic (CT) reconstructions. We propose a novel sinogram denoising algorithm inspired by the modern field of signal processing on graphs. Graph based methods often perform better than standard filtering operations since they can exploit the signal structure. This makes the sinogram an ideal candidate for graph based denoising since it generally has a piecewise smooth structure. We test our method with a variety of phantoms and different reconstruction methods. Our numerical study shows that the proposed algorithm improves the performance of analytical filtered back-projection (FBP) and iterative methods ART (Kaczmarz) and SIRT (Cimmino).We observed that graph denoised sinogram always minimizes the error measure and improves the accuracy of the solution as compared to regular reconstructions.

cs.CV↗