arXiv ScienceSearch

arXiv subjects

F. Piergiovanni

Publications and source records attributed to F. Piergiovanni.

5 recordsLinked to original sources

Development of ion-beam sputtered silicon nitride thin films for low-noise mirror coatings of gravitational-wave detectors

Brownian thermal noise of thin-film coatings is a fundamental limit for high-precision experiments based on optical resonators such as gravitational-wave interferometers. Here we present the results of a research activity aiming to develop lower-noise ion-beam sputtered silicon nitride thin films compliant with the very stringent requirements on optical loss of gravitational-wave interferometers. In order to test the hypothesis of a correlation between the synthesis conditions of the films and their elemental composition and optical and mechanical properties, we varied the voltage, current intensity and composition of the sputtering ion beam, and we performed a broad campaign of characterizations. While the refractive index was found to monotonically depend on the beam voltage and linearly vary with the N/Si ratio, the optical absorption appeared to be strongly sensitive to other factors, as yet unidentified. However, by systematically varying the deposition parameters, an optimal working point was found. Thus we show that the loss angle and extinction coefficient of our thin films can be as low as $(1.0 \pm 0.1) \times 10^{-4}$ rad at $\sim$2.8 kHz and $(6.4 \pm 0.2) \times 10^{-6}$ at 1064 nm, respectively, after thermal treatment at 900 $^{\circ}$C. To the best of our knowledge, such loss angle value is the lowest ever measured on this class of thin films. We then used our silicon nitride thin films to design and produce a multi-material mirror coating showing a thermal noise amplitude of $(10.3 \pm 0.2) \times 10^{-18}$ m Hz$^{-1/2}$ at 100 Hz, which is 25\% lower than in current mirror coatings of the Advanced LIGO and Advanced Virgo interferometers, and an optical absorption as low as $(1.6 \pm 0.5)$ parts per million at 1064 nm.

physics.ins-det

Characterization of ion-beam-sputtered AlF$_3$ thin films for gravitational-wave interferometers

Thermal noise in amorphous coatings is a limitation for a wide range of precision experiments such as gravitational-wave detectors (GWDs). Mirrors for GWDs are composed of multiple thin layers of dielectric materials deposited on a substrate: the stack is made of layers with a high refractive index interleaved with layers of a low refractive index. The goal is to obtain high reflectivity and low thermal noise. In this paper we report on the optical and mechanical properties of ion-beam-sputtered aluminium fluoride (AlF$_3$) thin films which have one of the lowest refractive index among the known coating materials and we discuss their application in current and future GWDs.

physics.ins-det

Optical and mechanical properties of ion-beam-sputtered MgF$_2$ thin films for gravitational-wave interferometers

Brownian thermal noise associated with highly reflective coatings is a fundamental limit for several precision experiments, including gravitational-wave detectors. Research is currently ongoing to find coatings with low thermal noise that also fulfill strict optical requirements such as low absorption and scatter. We report on the optical and mechanical properties of ion-beam-sputtered magnesium fluoride thin films, and we discuss the application of such coatings in current and future gravitational-wave detectors.

physics.ins-det

Low-latency analysis pipeline for compact binary coalescences in the advanced gravitational wave detector era

The multi-band template analysis (MBTA) pipeline is a low-latency coincident analysis pipeline for the detection of gravitational waves (GWs) from compact binary coalescences. MBTA runs with a low computational cost, and can identify candidate GW events online with a sub-minute latency. The low computational running cost of MBTA also makes it useful for data quality studies. Events detected by MBTA online can be used to alert astronomical partners for electromagnetic follow-up. We outline the current status of MBTA and give details of recent pipeline upgrades and validation tests that were performed in preparation for the first advanced detector observing period. The MBTA pipeline is ready for the outset of the advanced detector era and the exciting prospects it will bring.

gr-qc

Displacement power spectrum measurement of a macroscopic optomechanical system at thermal equilibrium

The mirror relative motion of a suspended Fabry-Perot cavity is studied in the frequency range 3-10 Hz. The experimental measurements presented in this paper, have been performed at the Low Frequency Facility, a high finesse optical cavity 1 cm long suspended to a mechanical seismic isolation system identical to that one used in the VIRGO experiment. The measured relative displacement power spectrum is compatible with a system at thermal equilibrium within its environmental. In the frequency region above 3 Hz, where seismic noise contamination is negligible, the measurement distribution is stationary and Gaussian, as expected for a system at thermal equilibrium. Through a simple mechanical model it is shown that: applying the fluctuation dissipation theorem the measured power spectrum is reproduced below 90 Hz and noise induced by external sources are below the measurement.

gr-qc