arXiv ScienceSearch

arXiv subjects

F. Moretti

Publications and source records attributed to F. Moretti.

9 recordsLinked to original sources

A note on momentum subtraction schemes for quark bilinears and semileptonic operators

In this work we examine a family of regularization invariant (RI) symmetric momentum (SMOM) schemes for semi-leptonic operators. By working with chirally symmetric and massless QCD, we relate the semi-leptonic operators with their corresponding flavor-changing vector currents, whose renormalization in pure QCD is protected by the Ward identity. For the latter, we extend the original RI/SMOM scheme [Sturm et al. 2009] to a family projectors suitable to be promoted to the semi-leptonic case and demonstrate their equivalence to Ref. [Gorbahn et al. 2023], relevant in particular for the perturbative calculation of the corresponding Wilson coefficients.

hep-lat

Absolute light yield of the EJ-204 plastic scintillator

The absolute light yield of a scintillator, defined as the number of scintillation photons produced per unit energy deposited, is a useful quantity for scintillator development, research, and applications. Yet, literature data on the absolute light yield of organic scintillators are limited. The goal of this work is to assess the suitability of the EJ-204 plastic scintillator from Eljen Technology to serve as a reference standard for measurements of the absolute light yield of organic scintillators. Four EJ-204 samples were examined: two manufactured approximately four months prior and stored in high-purity nitrogen, and two aged approximately eleven years and stored in ambient air. The scintillator response was measured using a large-area avalanche photodiode calibrated using low energy $\gamma$-ray and X-ray sources. The product of the quantum efficiency of the photodetector and light collection efficiency of the housing was characterized using an experimentally-benchmarked optical photon simulation. The average absolute light yield of the fresh samples, 9100 $\pm$ 400 photons per MeV, is lower than the manufacturer-reported value of 10400 photons per MeV. Moreover, the aged samples demonstrated significantly lower light yields, deviating from the manufacturer specification by as much as 26\%. These results are consistent with recent work showcasing environmental aging in plastic scintillators and suggest that experimenters should use caution when deploying plastic scintillators in photon counting applications.

physics.ins-det

Torsional birefringence in metric-affine Chern-Simons gravity: gravitational waves in late-time cosmology

In the context of the metric-affine Chern-Simons gravity endowed with projective invariance, we derive analytical solutions for torsion and nonmetricity in the homogeneous and isotropic cosmological case, described by a flat Friedmann-Robertson-Walker metric. We discuss in some details the general properties of the cosmological solutions in the presence of a perfect fluid, such as the dynamical stability and the emergence of big bounce points, and we examine the structure of some specific solutions reproducing de Sitter and power law behaviours for the scale factor. Then, we focus on first-order perturbations in the de Sitter scenario, and we study the propagation of gravitational waves in the adiabatic limit, looking at tensor and scalar polarizations. In particular, we find that metric tensor modes couple to torsion tensor components, leading to the appearance, as in the metric version of Chern-Simons gravity, of birefringence, characterized by different dispersion relations for the left and right circularized polarization states. As a result, the purely tensor part of torsion propagates like a wave, while nonmetricity decouples and behaves like a harmonic oscillator. Finally, we discuss scalar modes, outlining as they decay exponentially in time and do not propagate.

gr-qc

Semileptonic weak Hamiltonian to $\mathcal{O}(\alpha \alpha_s(\mu_{\mathrm{Lattice}}))$ in momentum-space subtraction schemes

The CKM unitarity precision test of the Standard Model requires a systematic treatment of electromagnetic and strong corrections for semi-leptonic decays. Electromagnetic corrections require the renormalization of a semileptonic four-fermion operator. In this work we calculate the $\mathcal{O}(\alpha\alpha_s)$ perturbative scheme conversion between the $\bar{\rm MS}$ scheme and several momentum-space subtraction schemes, which can also be implemented on the lattice. We consider schemes defined by MOM and SMOM kinematics and emphasize the importance of the choice of projector for each scheme. The conventional projector, that has been used in the literature for MOM kinematics, generates QCD corrections to the conversion factor that do not vanish for $\alpha=0$ and which generate an artificial dependence on the lattice matching scale that would only disappear after summing all orders of perturbation theory. This can be traced to the violation of a Ward identity that holds in tha $\alpha =0$ limit. We show how to remedy this by judicious choices of projector, and prove that the Wilson coefficients in those schemes are free from pure QCD contributions. The resulting Wilson coefficients (and operator matrix elements) have greatly reduced scale dependence. Our choice of the $\bar{\rm MS}$ scheme over the traditional $W$-mass scheme is motivated by the fact that, besides being more tractable at higher orders, unlike the latter it allows for a transparent separation of scales. We exploit this to obtain renormalization-group-improved leading-log and next-to-leading-log strong corrections to the electromagnetic contributions and study the (QED-induced) dependence on the lattice matching scale.

hep-ph

A Call to Arms Control: Synergies between Nonproliferation Applications of Neutrino Detectors and Large-Scale Fundamental Neutrino Physics Experiments

The High Energy Physics community can benefit from a natural synergy in research activities into next-generation large-scale water and scintillator neutrino detectors, now being studied for remote reactor monitoring, discovery and exclusion applications in cooperative nonproliferation contexts. Since approximately 2010, US nonproliferation researchers, supported by the National Nuclear Security Administration (NNSA), have been studying a range of possible applications of relatively large (100 ton) to very large (hundreds of kiloton) water and scintillator neutrino detectors. In parallel, the fundamental physics community has been developing detectors at similar scales and with similar design features for a range of high-priority physics topics, primarily in fundamental neutrino physics. These topics include neutrino oscillation studies at beams and reactors, solar, and geological neutrino measurements, supernova studies, and others. Examples of ongoing synergistic work at U.S. national laboratories and universities include prototype gadolinium-doped water and water-based and opaque scintillator test-beds and demonstrators, extensive testing and industry partnerships related to large area fast position-sensitive photomultiplier tubes, and the development of concepts for a possible underground kiloton-scale water-based detector for reactor monitoring and technology demonstrations. Some opportunities for engagement between the two communities include bi-annual Applied Antineutrino Physics conferences, collaboration with U.S. National Laboratories engaging in this research, and occasional NNSA funding opportunities supporting a blend of nonproliferation and basic science R&D, directed at the U.S. academic community.

physics.ins-det

Comparative scintillation performance of EJ-309, EJ-276, and a novel organic glass

An organic glass scintillator developed by Sandia National Laboratories was characterized in terms of its light output and pulse shape discrimination (PSD) properties and compared to commercial liquid (EJ-309) and plastic (EJ-276) organic scintillators. The electron light output was determined through relative comparison of the $^{137}$Cs Compton edge location. The proton light yield was measured using a double time-of-flight technique at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable broad-spectrum neutron source and an array of pulse-shape-discriminating observation scintillators, a continuous measurement of the proton light yield was performed for EJ-309 (200 keV$-$3.2 MeV), EJ-276 (170 keV$-$4.9 MeV), and the organic glass (50 keV$-$20 MeV). Finally, the PSD properties of the organic glass, EJ-309, and EJ-276 were evaluated using an AmBe source and compared via a figure-of-merit metric. The organic glass exhibited a higher electron light output than both EJ-309 and EJ-276. Its proton light yield and PSD performance were comparable to EJ-309 and superior to that of EJ-276. With these performance characteristics, the organic glass scintillator is well poised to replace current state-of-the-art PSD-capable scintillators in a range of fast neutron detection applications.

physics.ins-det

GaAs as a bright cryogenic scintillator for the direct dark matter detection

The optical and scintillation properties of undoped, Si-doped, and Si, B co-doped GaAs samples were studied. The light yield specification and X-ray luminescence of GaAs over a wide IR region by using Si and InGaAs photodetectors are presented. The undoped GaAs demonstrated a narrow emission band at 838 nm (1.48 eV) and a low light output of about 2 ph/keV. The GaAs:Si is characterized by three broad luminescence bands at 830 nm (1.49 eV), 1070 nm (1.16 eV), 1335 nm (0.93 eV) and a light output of about 71 ph/keV. In the case of GaAs:(Si, B), four luminescence bands at 860 nm (1.44 eV), 930 nm (1.33 eV), 1070 nm (1.16 eV) and 1335 nm (0.93 eV) were observed. A high light yield higher than 125 ph/keV was estimated for the co-doped sample. The applications of low energy gap semiconductors as cryogenic scintillators for particle detection are discussed. The GaAs is a promising crystal for a cryogenic scintillator for the dark matter (DM) detection.

physics.ins-det

Cerenkov light identification with Si low-temperature detectors with Neganov-Luke effect-enhanced sensitivity

A new generation of cryogenic light detectors exploiting Neganov-Luke effect to enhance the thermal signal has been used to detect the Cherenkov light emitted by the electrons interacting in TeO$_{2}$ crystals. With this mechanism a high significance event-by-event discrimination between alpha and beta/gamma interactions at the $^{130}$Te neutrino-less double beta decay Q-value - (2527.515 $\pm$ 0.013) keV - has been demonstrated. This measurement opens the possibility of drastically reducing the background in cryogenic experiments based on TeO$_{2}$.

physics.ins-det