arXiv ScienceSearch

arXiv subjects

F. Collamati

Publications and source records attributed to F. Collamati.

18 recordsLinked to original sources

Interim report for the International Muon Collider Collaboration (IMCC)

The International Muon Collider Collaboration (IMCC) [1] was established in 2020 following the recommendations of the European Strategy for Particle Physics (ESPP) and the implementation of the European Strategy for Particle Physics-Accelerator R&D Roadmap by the Laboratory Directors Group [2], hereinafter referred to as the the European LDG roadmap. The Muon Collider Study (MuC) covers the accelerator complex, detectors and physics for a future muon collider. In 2023, European Commission support was obtained for a design study of a muon collider (MuCol) [3]. This project started on 1st March 2023, with work-packages aligned with the overall muon collider studies. In preparation of and during the 2021-22 U.S. Snowmass process, the muon collider project parameters, technical studies and physics performance studies were performed and presented in great detail. Recently, the P5 panel [4] in the U.S. recommended a muon collider R&D, proposed to join the IMCC and envisages that the U.S. should prepare to host a muon collider, calling this their "muon shot". In the past, the U.S. Muon Accelerator Programme (MAP) [5] has been instrumental in studies of concepts and technologies for a muon collider.

physics.acc-ph

Muon detection in electron-positron annihilation for muon collider studies

The investigation of the energy frontier in physics requires novel concepts for future colliders. The idea of a muon collider is very appealing since it would allow to study particle collisions at up to tens of TeV energy, while offering a cleaner experimental environment with respect to hadronic colliders. One key element in the muon collider design is the low-emittance muon production. Recently,the Low EMittance Muon Accelerator (LEMMA) collaboration has explored the muon pair production close to its kinematic threshold by annihilating 45 GeV positrons with electrons in a low Z material target. In this configuration, muons are emerging from the target with a naturally low-emittance. In this paper we describe the performance of a system, to study this production mechanism, that consists in several segmented absorbers with alternating active layers composed of fast Cherenkov detectors together with a muon identification technique based on this detector. Passive layers were made of tungsten. We collected data corresponding to muon and electron beams produced at the H2 line in the North Area of the European Organization for Nuclear Research (CERN) in September 2018.

physics.ins-det

Characterization of cubic Li$_{2}$$^{100}$MoO$_4$ crystals for the CUPID experiment

The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta decay search. In this work, we characterised cubic crystals that, compared to the cylindrical crystals used by CUPID-Mo, are more appealing for the construction of tightly packed arrays. We measured an average energy resolution of (6.7$\pm$0.6) keV FWHM in the region of interest, approaching the CUPID target of 5 keV FWHM. We assessed the identification of $\alpha$ particles with and without a reflecting foil that enhances the scintillation light collection efficiency, proving that the baseline design of CUPID already ensures a complete suppression of this $\alpha$-induced background contribution. We also used the collected data to validate a Monte Carlo simulation modelling the light collection efficiency, which will enable further optimisations of the detector.

physics.ins-det

A CUPID Li$_{2}$$^{100}$MoO$_4$ scintillating bolometer tested in the CROSS underground facility

A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2\beta$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $\gamma$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$\sigma$) between $\gamma$($\beta$) and $\alpha$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $\mu$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2\beta$ decay in CROSS and CUPID projects.

physics.ins-det

Novel technique for the study of pile-up events in cryogenic bolometers

Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pile-up events with a programmable waveform generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pile-up events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pile-up pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pile-up events with rise time of ~15ms down to time separation between the individual events of about 2ms.

physics.ins-det

Report on the ECFA Early-Career Researchers Debate on the 2020 European Strategy Update for Particle Physics

A group of Early-Career Researchers (ECRs) has been given a mandate from the European Committee for Future Accelerators (ECFA) to debate the topics of the current European Strategy Update (ESU) for Particle Physics and to summarise the outcome in a brief document [1]. A full-day debate with 180 delegates was held at CERN, followed by a survey collecting quantitative input. During the debate, the ECRs discussed future colliders in terms of the physics prospects, their implications for accelerator and detector technology as well as computing and software. The discussion was organised into several topic areas. From these areas two common themes were particularly highlighted by the ECRs: sociological and human aspects; and issues of the environmental impact and sustainability of our research.

hep-ex

Study of muon pair production from positron annihilation at threshold energy

The muon collider represents one of the most promising solutions for a future machine exploring the high energy frontier, but several challenges due to the 2.2 $\mu$sec muon lifetime at rest have to be carefully considered. The LEMMA project is investigating the possibility of producing low emittance muon/antimuon pairs from the e$^+$e$^-$ annihilation process at threshold energy, resulting in small transverse emittance beams without any additional beam cooling. However most of the measurements available are performed at higher $\sqrt{s}$ values. It is therefore necessary to measure muons production in positron annihilation at threshold energy and compare the experimental results with the predictions in this specific energy regime. Apart from being a topic of physical interest by itself, these near to threshold measurements can have a sizeable impact on the estimation of the ultimate luminosity achievable in a muon collider with the LEMMA injection scheme.

hep-ex

Positron driven muon source for a muon collider

The design of a future multi-TeV muon collider needs new ideas to overcome the technological challenges related to muon production, cooling, accumulation and acceleration. In this paper a layout of a positron driven muon source known as the Low EMittance Muon Accelerator (LEMMA) concept is presented. The positron beam, stored in a ring with high energy acceptance and low emittance, is extracted and driven to a multi-target system, to produce muon pairs at threshold. This solution alleviates the issues related to the power deposited and the integrated Peak Energy Density Deposition (PEDD) on the targets. Muons produced in the multi-target system will then be accumulated before acceleration and injection in the collider. A multi-target line lattice has been designed to cope with the focusing of both the positron and muon beams. Studies on the number, material and thickness of the targets have been carried out. A general layout of the overall scheme and a description is presented, as well as plans for future R&D.

physics.acc-ph

Low emittance muon accelerator studies with production from positrons on target

A new scheme to produce very low emittance muon beams using a positron beam of about 45~GeV interacting on electrons on target is presented. One of the innovative topics to be investigated is the behaviour of the positron beam stored in a low emittance ring with a thin target, that is directly inserted in the ring chamber to produce muons. Muons can be immediately collected at the exit of the target and transported to two $\mu^+$ and $\mu^-$ accumulator rings and then accelerated and injected in muon collider rings. We focus in this paper on the simulation of the e$^+$ beam interacting with the target, the effect of the target on the 6-D phase space and the optimization of the e$^+$ ring design to maximize the energy acceptance. We will investigate the performance of this scheme, ring plus target system, comparing different multi-turn simulations. The source is considered for use in a multi-TeV collider in ref.[1]

physics.acc-ph

First Ex-Vivo Validation of a Radioguided Surgery Technique with beta- Radiation

Purpose: A radio-guided surgery technique with beta- -emitting radio-tracers was suggested to overcome the effect of the large penetration of gamma radiation. The feasibility studies in the case of brain tumors and abdominal neuro-endocrine tumors were based on simulations starting from PET images with several underlying assumptions. This paper reports, as proof-of-principle of this technique, an ex-vivo test on a meningioma patient. This test allowed to validate the whole chain, from the evaluation of the SUV of the tumor, to the assumptions on the bio-distribution and the signal detection. Methods: A patient affected by meningioma was administered 300 MBq of 90Y-DOTATOC. Several samples extracted from the meningioma and the nearby Dura Mater were analyzed with a beta- probe designed specifically for this radio-guided surgery technique. The observed signals were compared both with the evaluation from the histology and with the Monte Carlo simulation. Results: we obtained a large signal on the bulk tumor (105 cps) and a significant signal on residuals of $\sim$0.2 ml (28 cps). We also show that simulations predict correctly the observed yields and this allows us to estimate that the healthy tissues would return negligible signals (~1 cps). This test also demonstrated that the exposure of the medical staff is negligible and that among the biological wastes only urine has a significant activity. Conclusions: This proof-of-principle test on a patient assessed that the technique is feasible with negligible background to medical personnel and confirmed that the expectations obtained with Monte Carlo simulations starting from diagnostic PET images are correct.

physics.ins-det

Secondary radiation measurements for particle therapy applications: nuclear fragmentation produced by $^4$He ion beams in a PMMA target

Nowadays there is a growing interest in Particle Therapy treatments exploiting light ion beams against tumors due to their enhanced Relative Biological Effectiveness and high space selectivity. In particular promising results are obtained by the use of $^4$He projectiles. Unlike the treatments performed using protons, the beam ions can undergo a fragmentation process when interacting with the atomic nuclei in the patient body. In this paper the results of measurements performed at the Heidelberg Ion-Beam Therapy center are reported. For the first time the absolute fluxes and the energy spectra of the fragments - protons, deuterons, and tritons - produced by $^4$He ion beams of 102, 125 and 145 MeV/u energies on a poly-methyl methacrylate target were evaluated at different angles. The obtained results are particularly relevant in view of the necessary optimization and review of the Treatment Planning Software being developed for clinical use of $^4$He beams in clinical routine and the relative benchmarking of Monte Carlo algorithm predictions.

physics.med-ph

Secondary radiation measurements for particle therapy applications: Charged secondaries produced by 4He and 12C ion beams in a PMMA target at large angle

Measurements performed with the purpose of characterizing the charged secondary radiation for dose release monitoring in particle therapy are reported. Charged secondary yields, energy spectra and emission profiles produced in poly-methyl methacrylate (PMMA) target by 4He and 12C beams of different therapeutic energies were measured at 60 and 90 degree with respect to the primary beam direction. The secondary yields of protons produced along the primary beam path in PMMA target were obtained. The energy spectra of charged secondaries were obtained from time-of-flight information, whereas the emission profiles were reconstructed exploiting tracking detector information. The measured charged secondary yields and emission profiles are in agreement with the results reported in literature and confirm the feasibility of ion beam therapy range monitoring using 12C ion beam. The feasibility of range monitoring using charged secondary particles is also suggested for 4He ion beam.

physics.med-ph

A novel radioguided surgery technique exploiting $β^{-}$ decays

The background induced by the high penetration power of the gamma radiation is the main limiting factor of the current Radio-guided surgery (RGS). To partially mitigate it, a RGS with beta+ emitting radio-tracers has been suggested in literature. Here we propose the use of beta- emitting radio-tracers and beta- probes and discuss the advantage of this method with respect to the previously explored ones: the electron low penetration power allows for simple and versatile probes and could extend RGS to tumours for which background originating from nearby healthy tissue makes gamma probes less effective. We developed a beta- probe prototype and studied its performances on phantoms. By means of a detailed simulation we have also extrapolated the results to estimate the performances in a realistic case of meningioma, pathology which is going to be our first in-vivo test case. A good sensitivity to residuals down to 0.1ml can be reached within 1s with an administered activity smaller than those for PET-scans thus making the radiation exposure to medical personnel negligible.

physics.med-ph

Extended calibration range for prompt photon emission in ion beam irradiation

Monitoring the dose delivered during proton and carbon ion therapy is still a matter of research. Among the possible solutions, several exploit the measurement of the single photon emission from nuclear decays induced by the irradiation. To fully characterize such emission the detectors need development, since the energy spectrum spans the range above the MeV that is not traditionally used in medical applications. On the other hand, a deeper understanding of the reactions involving gamma production is needed in order to improve the physic models of Monte Carlo codes, relevant for an accurate prediction of the prompt-gamma energy spectrum.This paper describes a calibration technique tailored for the range of energy of interest and reanalyzes the data of the interaction of a 80MeV/u fully stripped carbon ion beam with a Poly-methyl methacrylate target. By adopting the FLUKA simulation with the appropriate calibration and resolution a significant improvement in the agreement between data and simulation is reported.

physics.med-ph

Properties of para-terphenyl as detector for alpha, beta and gamma radiation

Organic scintillators are often chosen as radiation detectors for their fast decay time and their low Z, while inorganic ones are used when high light ields are required. In this paper we show that a para-terphenyl based detector has a blend of properties of the two categories that can be optimal for energy and position measurements of low energy charged particles. On 0.1% diphenylbutadiene doped para-terphenyl samples we measure a light yield 3.5+-0.2 times larger than a typical organic scintillator (EJ-200), and a rejection power for 660 keV photons, with respect to electrons of the same energy, ranging between 3-11%, depending on the signal threshold. We also measure a light attenuation length = 4.73+-0.06 mm and we demonstrate that, with the measurements performed in this paper, a simulation based on FLUKA can properly reproduce the measured spectra.

physics.ins-det

Study of the time and space distribution of beta+ emitters from 80 MeV/u carbon ion beam irradiation on PMMA

Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments and the on-line knowledge of the Bragg peak position is still a matter of research. A possible technique exploits the collinear $511\ \kilo\electronvolt$ photons produced by positrons annihilation from $β^+$ emitters created by the beam. This paper reports rate measurements of the $511\ \kilo\electronvolt$ photons emitted after the interactions of a $80\ \mega\electronvolt / u$ fully stripped carbon ion beam at the Laboratori Nazionali del Sud (LNS) of INFN, with a Poly-methyl methacrylate target. The time evolution of the $β^+$ rate was parametrized and the dominance of $^{11}C$ emitters over the other species ($^{13}N$, $^{15}O$, $^{14}O$) was observed, measuring the fraction of carbon ions activating $β^+$ emitters $A_0=(10.3\pm0.7)\cdot10^{-3}$. The average depth in the PMMA of the positron annihilation from $β^+$ emitters was also measured, $D_{β^+}=5.3\pm1.1\ \milli\meter$, to be compared to the expected Bragg peak depth $D_{Bragg}=11.0\pm 0.5\ \milli\meter$ obtained from simulations.

physics.med-ph

Charged particle's flux measurement from PMMA irradiated by 80 MeV/u carbon ion beam

Hadrontherapy is an emerging technique in cancer therapy that uses beams of charged particles. To meet the improved capability of hadrontherapy in matching the dose release with the cancer position, new dose monitoring techniques need to be developed and introduced into clinical use. The measurement of the fluxes of the secondary particles produced by the hadron beam is of fundamental importance in the design of any dose monitoring device and is eagerly needed to tune Monte Carlo simulations. We report the measurements done with charged secondary particles produced from the interaction of a 80 MeV/u fully stripped carbon ion beam at the INFN Laboratori Nazionali del Sud, Catania, with a Poly-methyl methacrylate target. Charged secondary particles, produced at 90$\degree$ with respect to the beam axis, have been tracked with a drift chamber, while their energy and time of flight has been measured by means of a LYSO scintillator. Secondary protons have been identified exploiting the energy and time of flight information, and their emission region has been reconstructed backtracking from the drift chamber to the target. Moreover a position scan of the target indicates that the reconstructed emission region follows the movement of the expected Bragg peak position. Exploting the reconstruction of the emission region, an accuracy on the Bragg peak determination in the submillimeter range has been obtained. The measured differential production rate for protons produced with $E^{\rm Prod}_{\rm kin} >$ 83 MeV and emitted at 90$\degree$ with respect to the beam line is: $dN_{\rm P}/(dN_{\rm C}dΩ)(E^{\rm Prod}_{\rm kin} > 83 {\rm ~MeV}, θ=90\degree)= (2.69\pm 0.08_{\rm stat} \pm 0.12_{\rm sys})\times 10^{-4} sr^{-1}$.

physics.med-ph

Precise measurement of prompt photon emission for carbon ion therapy

Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments is still a matter of research. A possible technique exploits the information provided by single photon emission from nuclear decays induced by the irradiation. This paper reports the measurements of the spectrum and rate of such photons produced from the interaction of a 80 MeV/u fully stripped carbon ion beam at the Laboratori Nazionali del Sud of INFN, Catania, with a Poly-methyl methacrylate target. The differential production rate for photons with energy E > 2 MeV and emitted at 90 degree is found to be $dN_{\gamma}/(dN_C d\Omega)=(2.92\pm 0.19)\times 10^{-2}$sr$^{-1}$.

physics.med-ph