arXiv ScienceSearch

arXiv subjects

Eric Weeks

Publications and source records attributed to Eric Weeks.

7 recordsLinked to original sources

An Open Source RFSoC-based Readout Electronics System for Arrays of Kinetic Inductance Detectors and Superconducting Resonators

We present a novel readout electronics system for large arrays of superconducting electromagnetic resonators, such as kinetic inductance detectors (KIDs), based on a Radio Frequency System on Chip (RFSoC) architecture. Each channel in the readout system is designed for frequency division multiplexing of up to 1024 high quality factor resonances placed on a single microwave transmission line at unique frequencies within a 512 MHz bandwidth. We describe the design of the digital and analog signal processing chains for the implementation of a two-channel 2048-resonator system on the Xilinx ZCU111 RFSoC evaluation board in combination with a custom intermediate frequency (IF) system to convert the RFSoC band to higher frequencies up to 4 GHz. We also detail an associated software interface that provides a range of tools commonly utilized for characterizing KID resonators and for operating them as part of a photometric millimeter-wave imager. We additionally provide noise characterizations of the individual readout components, along with the complete readout system in isolation and in operation to readout KID resonators.

physics.ins-det

Spaceflight KID Readout Electronics for PRIMA

We present the design and testing of a prototype multiplexing kinetic inductance detector (KID) readout electronics for the PRobe far-Infrared Mission for Astrophysics (PRIMA) space mission. PRIMA is a Probe-class astrophysics mission concept that will answer fundamental questions about the formation of planetary systems, the co-evolution of stars and supermassive black holes in galaxies, and the rise of heavy elements and dust over cosmic time. The readout electronics for PRIMA must be compatible with operation at Earth-Sun L2 and capable of multiplexing more than 1000 detectors over 2.5 GHz bandwidth while consuming around 30 W per readout chain. The electronics must also be capable of switching between the two instruments, which have different readout bands: the hyperspectral imager (PRIMAger, 2.6-4.9 GHz) and the spectrometer (FIRESS, 0.4-2.4 GHz). The PRIMA readout electronics use high-heritage SpaceCube digital electronics with a build-to-print SpaceCube Mini v3.0 board using a radiation-tolerant Kintex KU060 field programmable gate array (FPGA) and a custom high-speed digitizer board, along with RF electronics that provide filtering and power conditioning. We present the driving requirements for the system, as well as the hardware, firmware, software, and system-level design that meets those requirements.

astro-ph.IM

A Millimeter-Wave Photometric Camera for Long-Range Imaging Through Optical Obscurants Using Kinetic Inductance Detectors

Passive imaging through optical obscurants is a promising application for mm-wave sensing. We have thus developed the Superconducting Kinetic Inductance Passive Radiometer (SKIPR), a 150 GHz polarization-sensitive photometric camera optimized for terrestrial imaging using a focal plane array with 3,840 kinetic inductance detectors (KIDs). We present a full description of the instrument design, with a particular emphasis on the cryogenic system based on a Gifford-McMahon cryocooler with a two-stage Adiabatic Demagnetization Refrigerator and a dedicated 1.59 m crossed Dragone telescope with an altitude/azimuth mount. We include a detailed lab-based characterization of the KIDs, which results in a determination of their superconducting resonator parameters and optical properties. We also present in situ measurements from the telescope, including point-spread functions and noise characterization. In sum, we find that SKIPR performs as expected, providing diffraction-limited imaging with detector noise performance set by the random arrivals of photons from the ambient background. There is minimal variation in detector characteristics over the full SKIPR focal plane array, and the overall detector yield is 92 per cent.

astro-ph.IM

Superfluid-tight cryogenic receiver with continuous sub-Kelvin cooling for EXCLAIM

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne telescope designed to survey star formation over cosmological time scales using intensity mapping in the 420 - 540 GHz frequency range. EXCLAIM uses a fully cryogenic telescope coupled to six on-chip spectrometers featuring kinetic inductance detectors (KIDs) to achieve high sensitivity, allowing for fast integration in dark atmospheric windows. The telescope receiver is cooled to $\approx$ 1.7 K by immersion in a superfluid helium bath and enclosed in a superfluid-tight shell with a meta-material anti-reflection coated silicon window. In addition to the optics and the spectrometer package, the receiver contains the magnetic shielding, the cryogenic segment of the spectrometer readout, and the sub-Kelvin cooling system. A three-stage continuous adiabatic demagnetization refrigerator (CADR) keeps the detectors at 100 mK while a $^4$He sorption cooler provides a 900 mK thermal intercept for mechanical suspensions and coaxial cables. We present the design of the EXCLAIM receiver and report on the flight-like testing of major receiver components, including the superfluid-tight receiver window and the sub-Kelvin coolers.

astro-ph.IM

Operational Optimization to Maximize Dynamic Range in EXCLAIM Microwave Kinetic Inductance Detectors

Microwave Kinetic Inductance Detectors (MKIDs) are highly scalable detectors that have demonstrated nearly background-limited sensitivity in the far-infrared from high-altitude balloon-borne telescopes and space-like laboratory environments. In addition, the detectors have a rich design space with many optimizable parameters, allowing highly sensitive measurements over a wide dynamic range. For these reasons, MKIDs were chosen for the Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM), a balloon-borne telescope targeting nearly background-limited performance in a high-altitude atmospheric environment from 420-540 GHz. We describe MKID optimization in the specific context of EXCLAIM and provide general results that apply to broader applications. Extending the established approach of tone frequency tracking, we show that readout power optimization enables significant, further improvement in dynamic range.

astro-ph.IM

CCAT-prime: Characterization of the First 280 GHz MKID Array for Prime-Cam

The Prime-Cam receiver on the Fred Young Submillimeter Telescope for the CCAT-prime project aims to address important astrophysical and cosmological questions with sensitive broadband, polarimetric, and spectroscopic measurements. The primary frequency bands in development include 280, 350, and 850 GHz for the polarization-sensitive broadband channels and 210--420 GHz for the spectrometers. Microwave kinetic inductance detectors (MKIDs) are a natural choice of detector technology for the simplicity in multiplexed readout needed for large format arrays at these high frequencies. We present here the initial lab characterization of the feedhorn-coupled 280 GHz polarimetric MKID array, and outline the plans for the subsequent MKID arrays and the development of the testbed to characterize them.

astro-ph.IM

Mechanical properties of model colloidal mono-crystals

We investigate the elastic and yielding properties of two dimensional defect-free mono-crystals made of highly monodisperse droplets. Crystals are compressed between two parallel boundaries of which one acts as a force sensor. As the available space between boundaries is reduced, the crystal goes through successive row-reduction transitions. For small compression forces, the crystal responds elastically until a critical force is reached and the assembly fractures in a single catastrophic global event. Correspondingly there is a peak in the force measurement associated with each row-reduction. The elastic properties of ideal mono-crystal samples are fully captured by a simple analytical model consisting of an assembly of individual capillary springs. The yielding properties of the crystal are captured with a minimal bond breaking model.

cond-mat.soft