Data-driven estimation of design heating loads for HVAC equipment sizing

Oversized heating and cooling equipment can unnecessarily increase up-front costs, energy costs, pollutant emissions, and strain on electrical infrastructure. This paper develops two data-driven methods for estimating heating loads at design conditions to improve equipment sizing. One method uses smart thermostat data; the other uses utility bills. We test the methods on a dataset that we gathered from 74 detached single-family houses in five United States climate zones. The dataset includes smart thermostat time-series data, monthly utility bills, weather data, existing equipment specifications, and Manual J design load calculations (the United States industry standard) purchased from practitioners. The two methods have strong goodness-of-fit statistics individually and show fair agreement with each other. On average over the 74 houses, existing heating equipment is 2.75 (2.5th to 97.5th empirical percentile: 1.34-6.52) times larger than the thermostat-method estimate and 2.96 (1.36-7.76 times larger than the bill-method estimate. As implemented by practitioners, the Manual J estimate is 2.26 (0.87-5.21) times larger on average than the thermostat-method estimate and 2.35 (1.02-5.28) times larger than the bill-method estimate. We discuss prospects for implementing the data-driven methods at scale and for incorporating data-driven sizing into industry standards.

eess.SY

Laboratory and field testing of a residential heat pump retrofit for a DC solar nanogrid

Residential buildings are increasingly integrating large devices that run natively on direct current (DC), such as solar photovoltaics, electric vehicles, stationary batteries, and DC motors that drive heat pumps and other major appliances. Today, these natively-DC devices typically connect within buildings through alternating current (AC) distribution systems, entailing significant energy losses due to conversions between AC and DC. This paper investigates the alternative of connecting DC devices through DC distribution. Specifically, this paper shows through laboratory and field experiments that an off-the-shelf residential heat pump designed for conventional AC systems can be powered directly on DC with few hardware modifications and little change in performance. Supporting simulations of a DC nanogrid including {historical heat pump and rest-of-house load measurements,} a solar photovoltaic array, and a stationary battery suggest that connecting these devices through DC distribution could decrease annual electricity bills by 12.5% with an after-market AC-to-DC heat pump retrofit and by 16.7% with a heat pump designed to run on DC. The associated savings in gross nanogrid energy are 8% and 9.2%, respectively.

eess.SY

Model predictive control lowers barriers to adoption of heat-pump water heaters: A field study

Electric heat-pump water heaters (HPWHs) could reduce the energy costs, emissions, and power grid impacts associated with water heating, the second-largest energy use in United States housing. However, most HPWHs today require 240 V circuits to power the backup resistance heating elements they use to maintain comfort during large water draws. Installing a 240 V circuit can increase the up-front cost of a HPWH by half or more. This paper develops and field-tests the first control system that enables a 120 V HPWH to efficiently maintain comfort without resistance heating elements. The novel model predictive control (MPC) system enables pre-heating in anticipation of large water draws, which it forecasts using an ensemble of machine learning predictors. By shifting electrical load over time, MPC also reduces energy costs on average by 23% and 28% under time-of-use pricing and hourly pricing, respectively, relative to a 240 V HPWH with standard controls. Compared to the increasingly common practice in 120 V HPWHs of storing water at a constant, high temperature (60 {\deg}C) to ensure comfort, MPC saves 37% energy on average. In addition to demonstrating MPC's benefits in a real, occupied house, this paper discusses implementation challenges and costs. A simple payback analysis suggests that a 120 V HPWH, operated by the MPC system developed here, would be economically attractive in most installation scenarios.

eess.SY

Comparative Field Deployment of Reinforcement Learning and Model Predictive Control for Residential HVAC

Model Predictive Control (MPC) has demonstrated significant performance improvements over today's control methods for residential Heating, Ventilation, and Air Conditioning (HVAC), but deploying MPC often requires substantial engineering effort. Reinforcement Learning (RL) may offer comparable performance with easier deployment, but its practical application for residential HVAC remains largely undemonstrated, leaving open questions related to occupant comfort and data requirements. To investigate these issues, we deployed one MPC variant and one model-based RL variant for one month each in an occupied house in a cold climate. The controllers adjusted an air-to-air heat pump's thermostat temperature setpoint based on measurements of the indoor temperature and the electric power used for heating. Relative to constant-setpoint operation, MPC saved 18.1\% (95\% confidence interval: 4.4 to 30.9\%) of weather-normalized heat pump energy and RL saved 20.9\% (2.6 to 38.3\%). MPC maintained acceptable occupant comfort. RL kept the house cooler, particularly during an initial adaptation phase, leading to three reports of occupant discomfort. The two algorithms had similar data requirements. We estimate that for a fresh deployment in another house, RL would take about one-third less engineering effort than MPC. While RL reduces deployment effort, it faces difficulties related to safe controller initialization and to mismatches between the modeled and true state and action spaces.

eess.SY

Lessons learned from field demonstrations of model predictive control and reinforcement learning for residential and commercial HVAC: A review

A large body of simulation research suggests that model predictive control (MPC) and reinforcement learning (RL) for heating, ventilation, and air-conditioning (HVAC) in residential and commercial buildings could reduce energy costs, pollutant emissions, and strain on power grids. Despite this potential, neither MPC nor RL has seen widespread industry adoption. Field demonstrations could accelerate MPC and RL adoption by providing real-world data that support the business case for deployment. Here we review 24 papers that document field demonstrations of MPC and RL in residential buildings and 80 in commercial buildings. After presenting demographic information -- such as experiment scopes, locations, and durations -- this paper analyzes experiment protocols and their influence on performance estimates. We find that 71% of the reviewed field demonstrations use experiment protocols that may lead to unreliable performance estimates. Over the remaining 29% that we view as reliable, the weighted-average cost savings, weighted by experiment duration, are 16% in residential buildings and 13% in commercial buildings. While these savings are potentially attractive, making the business case for MPC and RL also requires characterizing the costs of deployment, operation, and maintenance. Only 13 of the 104 reviewed papers report these costs or discuss related challenges. Based on these observations, we recommend directions for future field research, including: Improving experiment protocols; reporting deployment, operation, and maintenance costs; designing algorithms and instrumentation to reduce these costs; controlling HVAC equipment alongside other distributed energy resources; and pursuing emerging objectives such as peak shaving, arbitraging wholesale energy prices, and providing power grid reliability services.

eess.SY

Protecting residential electrical panels and service through model predictive control: A field study

Residential electrification - replacing fossil-fueled appliances and vehicles with electric machines - can significantly reduce greenhouse gas emissions and air pollution. However, installing electric appliances or vehicle charging in a residential building can sharply increase its current draws. In older housing, high current draws can jeopardize electrical infrastructure, such as circuit breaker panels or electrical service (the wires that connect a building to the distribution grid). Upgrading electrical infrastructure can entail long delays and high costs, so poses a significant barrier to electrification. This paper develops and field-tests a control system that avoids the need for electrical upgrades by keeping an electrified home's total current draw within the safe limits of its panel and service. In the proposed control architecture, a high-level controller plans device set-points over a rolling prediction horizon. A low-level controller monitors real-time conditions and ramps down devices if necessary. The control system was tested in an occupied, electrified single-family house with code-minimum insulation, an air-to-air heat pump and backup resistance heat, a resistance water heater, and a plug-in hybrid electric vehicle with Level I charging. The field tests spanned 31 winter days with outdoor temperatures as low as -20 C. The control system maintained the whole-home current within the safe limits of electrical panels and service rated at 100 A, a common rating for older houses in North America, by adjusting only the temperature set-points of the heat pump and water heater. Simulations suggest that the same 100 A limit could accommodate a second electric vehicle with Level II charging. The proposed control system could allow older homes to safely electrify without upgrading electrical panels or service, saving a typical household on the order of $2,000 to $10,000.

eess.SY

Humidity-Aware Model Predictive Control for Residential Air Conditioning: A Field Study

Model predictive control of residential air conditioning could reduce energy costs and greenhouse gas emissions while maintaining or improving occupants' thermal comfort. However, most approaches to predictive air conditioning control either do not model indoor humidity or treat it as constant. This simplification stems from challenges with modeling indoor humidity dynamics, particularly the high-order, nonlinear equations that govern heat and mass transfer between the air conditioner's evaporator coil and the indoor air. This paper develops a machine-learning approach to modeling indoor humidity dynamics that is suitable for real-world deployment at scale. This study then investigates the value of humidity modeling in four field tests of predictive control in an occupied house. The four field tests evaluate two different building models: One with constant humidity and one with time-varying humidity. Each modeling approach is tested in two different predictive controllers: One that focuses on reducing energy costs and one that focuses on constraining electric power below a utility-specified threshold. The two models lead to similar performance for reducing energy costs. Combining the results of this study and a prior heating study of the same house, the estimated year-round energy cost savings were $340-497 or 22-31% (95% confidence intervals); these savings were consistent across both humidity models. However, in the demand response tests, the simplifying assumption of constant humidity led to far more frequent and severe violations of the power constraint. These results suggest that accurate building models are important for nonlinear objectives, such as reducing or constraining peak demand, while for linear objectives such as reducing energy costs or emissions, model accuracy is less important.

eess.SY

Field demonstration of predictive heating control for an all-electric house in a cold climate

Efficient electric heat pumps that replace fossil-fueled heating systems could significantly reduce greenhouse gas emissions. However, electric heat pumps can sharply increase electricity demand, causing high utility bills and stressing the power grid. Residential neighborhoods could see particularly high electricity demand during cold weather, when heat demand rises and heat pump efficiencies fall. This paper presents the development and field demonstration of a predictive control system for an air-to-air heat pump with backup electric resistance heat. The control system adjusts indoor temperature set-points based on weather forecasts, occupancy conditions, and data-driven models of the building and heating equipment. Field tests from January to March of 2023 in an occupied, all-electric, 208 m^2 detached single-family house in Indiana, USA, included outdoor temperatures as low as -15 C. On average over these tests, the control system reduced daily heating energy use by 19% (95% confidence interval: 13--24%), energy used for backup heat by 38%, and the frequency of using the highest stage (19 kW) of backup heat by 83%. Concurrent surveys of residents showed that the control system maintained satisfactory thermal comfort. The control system could reduce the house's total annual heating costs by about $300 (95% confidence interval: 23--34%). These real-world results could strengthen the case for deploying predictive home heating control, bringing the technology one step closer to reducing emissions, utility bills, and power grid impacts at scale.