arXiv ScienceSearch

arXiv subjects

E. Price

Publications and source records attributed to E. Price.

5 recordsLinked to original sources

Optical calibration systems of the Pacific Ocean Neutrino Experiment

This work presents the design and performance characterization of the optical calibration systems produced for the Pacific Ocean Neutrino Experiment (P-ONE), which target gain, energy and time calibration in the detector. These systems include novel light-pulse driver circuitry based on gallium nitride field-effect transistor technology and its application to directional and isotropic, self-monitoring optical calibration instruments. A total of 330 directional light pulsers and two isotropic, 17-inch calibration modules (P-CALs) were produced for the first P-ONE line. We present the designs and performance of both the directional and isotropic calibration devices and perform detailed optical characterizations of both full-production batches. In a wavelength range of $365 - 520\,$nm, our developed driver circuits achieve emission intensities up to $10^{11}\,$photons and pulse widths as small as $1.4\,$ns, respectively. Light-pulse drivers and self-monitoring electronics in the P-CAL were characterized using the same experimental setup, and the instrument's optical-isotropy design was optimized in combination with a dedicated GEANT4-based simulation framework. The optimized P-CAL achieves a simulated isotropy grade of $1.00 \pm 0.01$ across the entire $4\pi\,$solid angle range. These simulation investigations were explicitly confirmed by dedicated measurements in both air and water using two independent experimental setups, and we report the results. With this, a detailed performance estimate for deployed P-CAL modules in P-ONE was possible.

physics.ins-det

Long term study of sedimentation and biofouling at Cascadia Basin, the site of the Pacific Ocean Neutrino Experiment

STRings for Absorption Length in Water (STRAW)-a and b were pathfinder instruments deployed to characterize the anticipated site of the Pacific Ocean Neutrino Experiment (P-ONE), which is a future neutrino telescope that will be located in the North Pacific Ocean. Measurements of the evolution of the optical transmission efficiency from STRAW-a showed a decline over the detector's lifetime for the upward-facing modules. Video footage of the pathfinders strongly suggested this decline was caused by biofouling and sedimentation. We measure the effect of biofouling and sedimentation to be a decrease in the transparency of upward-facing optical surfaces over 5 years of operations. A majority of downward-facing optical surfaces, which will dominate P-ONE's sensitivity to astrophysical sources, showed no visible biofouling. Extrapolations motivated by biological growth models estimated that these losses started around 2.5 years after deployment, and suggest a reduction in transparency ranging from 35$\%$ of the original to complete obscuration for the upward-facing modules. Samples of biofouling were taken in order to identify the microbial diversity of these organisms and inform potential intervention strategies. Results of the microbial samples and a candidate anti-biofouling strategy that will be tested on upcoming P-ONE instruments are discussed.

hep-ex

Prototype acoustic positioning system for the Pacific Ocean Neutrino Experiment

We present the design and initial performance characterization of the prototype acoustic positioning system intended for the Pacific Ocean Neutrino Experiment. It comprises novel piezo-acoustic receivers with dedicated filtering- and amplification electronics installed in P-ONE instruments and is complemented by a commercial system comprised of cabled and autonomous acoustic pingers for sub-sea installation manufactured by Sonardyne Ltd. We performed an in-depth characterization of the acoustic receiver electronics and their acoustic sensitivity when integrated into P-ONE pressure housings. These show absolute sensitivities of up to $-125\,$dB re V$^2/\mu$Pa$^2$ in a frequency range of $10-40\,$kHz. We furthermore conducted a positioning measurement campaign in the ocean by deploying three autonomous acoustic pingers on the seafloor, as well as a cabled acoustic interrogator and a P-ONE prototype module deployed from a ship. Using a simple peak-finding detection algorithm, we observe high accuracy in the tracking of relative ranging times at approximately $230-280\,\mu$s at distances of up to $1600\,$m, which is sufficient for positioning detectors in a cubic-kilometer detector and which can be further improved with more involved detection algorithms. The tracking accuracy is further confirmed by independent ranging of the Sonardyne system and closely follows the ship's drift in the wind measured by GPS. The absolute positioning shows the same tracking accuracy with its absolute precision only limited by the large uncertainties of the deployed pinger positions on the seafloor.

physics.ins-det

Spatial resolution and efficiency of prototype sensors for the LHCb VELO Upgrade

A comprehensive study of the spatial resolution and detection efficiency of sensor prototypes developed for the LHCb VELO upgrade is presented. Data samples were collected at the CERN SPS H8 beam line using a hadron mixture of protons and pions with momenta of approximately 180 GeV/c. The sensor performance was characterised using both irradiated and non-irradiated sensors. Irradiated samples were subjected to a maximum fluence of $\mathrm{8\times10^{15}~1~MeV~n_{eq}~cm^{-2}}$, of both protons and neutrons. The spatial resolution is measured comparing the detected hits to the position as predicted by tracks reconstructed by the Timepix3 telescope. The resolution is presented for different applied bias voltages and track angles, sensor thickness and implant size.

physics.ins-det

Charge collection properties of prototype sensors for the LHCb VELO upgrade

An extensive sensor testing campaign is presented, dedicated to measuring the charge collection properties of prototype candidates for the Vertex Locator (VELO) detector for the upgraded LHCb experiment. The charge collection is measured with sensors exposed to fluences of up to $8 \times 10^{15}~1~\mathrm{\,Me\kern -0.1em V}~ \mathrm{ \,n_{eq}}~{\mathrm{ \,cm}}^{-2}$, as well as with nonirradiated prototypes. The results are discussed, including the influence of different levels of irradiation and bias voltage on the charge collection properties. Charge multiplication is observed on some sensors that were nonuniformly irradiated with 24 GeV protons, to the highest fluence levels. An analysis of the charge collection near the guard ring region is also presented, revealing significant differences between the sensor prototypes. All tested sensor variants succeed in collecting the minimum required charge of 6000 electrons after the exposure to the maximum fluence.

physics.ins-det