arXiv ScienceSearch

arXiv subjects

Doyu Lee

Publications and source records attributed to Doyu Lee.

11 recordsLinked to original sources

Extended Haloscope Search and Exclusion of a Candidate Signal near 1.036 GHz

We report a follow-up axion haloscope search near 1.036 GHz that completes and extends our previous work [Phys. Rev. X 14, 031023 (2024)], in which a portion of the HEMT-based data could not be analyzed due to unrecorded experimental information. While recovering this dataset, we identified an excess near 1.036 GHz that satisfied our candidate-selection criteria, motivating dedicated validation studies, including independent cross-checks and re-examination with the original apparatus. The excess did not persist under these investigations and was not confirmed as an axion dark-matter signal. We subsequently extended the search over a 20-MHz band surrounding the candidate using a quantum-noise-limited amplifier, achieving sensitivity close to the Dine-Fischler-Srednicki-Zhitnitsky benchmark. In the absence of a confirmed signal, we set improved 90% confidence-level upper limits on the axion-photon coupling over the frequency range 1.026-1.045 GHz. This work highlights the importance of robust candidate-validation strategies as haloscope searches approach discovery-level sensitivity.

hep-ex

Extensive search for axion dark matter over 1\,GHz with CAPP's Main Axion eXperiment

We report an extensive high-sensitivity search for axion dark matter above 1\,GHz at the Center for Axion and Precision Physics Research (CAPP). The cavity resonant search, exploiting the coupling between axions and photons, explored the frequency (mass) range of 1.025\,GHz (4.24\,$μ$eV) to 1.185\,GHz (4.91\,$μ$eV). We have introduced a number of innovations in this field, demonstrating the practical approach of optimizing all the relevant parameters of axion haloscopes, extending presently available technology. The CAPP 12\,T magnet with an aperture of 320\,mm made of Nb$_3$Sn and NbTi superconductors surrounding a 37-liter ultralight-weight copper cavity is expected to convert DFSZ axions into approximately $10^2$ microwave photons per second. A powerful dilution refrigerator, capable of keeping the core system below 40\,mK, combined with quantum-noise limited readout electronics, achieved a total system noise of about 200\,mK or below, which corresponds to a background of roughly $4\times 10^3$ photons per second within the axion bandwidth. The combination of all those improvements provides unprecedented search performance, imposing the most stringent exclusion limits on axion--photon coupling in this frequency range to date. These results also suggest an experimental capability suitable for highly-sensitive searches for axion dark matter above 1\,GHz.

hep-ex

Search for the Sagittarius Tidal Stream of Axion Dark Matter around 4.55 $μ$eV

We report the first search for the Sagittarius tidal stream of axion dark matter around 4.55 $μ$eV using CAPP-12TB haloscope data acquired in March of 2022. Our result excluded the Sagittarius tidal stream of Dine-Fischler-Srednicki-Zhitnitskii and Kim-Shifman-Vainshtein-Zakharov axion dark matter densities of $ρ_a\gtrsim0.184$ and $\gtrsim0.025$ GeV/cm$^{3}$, respectively, over a mass range from 4.51 to 4.59 $μ$eV at a 90% confidence level.

hep-ex

Axion Dark Matter Search around 4.55 $μ$eV with Dine-Fischler-Srednicki-Zhitnitskii Sensitivity

We report an axion dark matter search at Dine-Fischler-Srednicki-Zhitnitskii sensitivity with the CAPP-12TB haloscope, assuming axions contribute 100\% of the local dark matter density. The search excluded the axion--photon coupling $g_{aγγ}$ down to about $6.2\times10^{-16}$ GeV$^{-1}$ over the axion mass range between 4.51 and 4.59 $μ$eV at a 90\% confidence level. The achieved experimental sensitivity can also exclude Kim-Shifman-Vainshtein-Zakharov axion dark matter that makes up just 13\% of the local dark matter density. The CAPP-12TB haloscope will continue the search over a wide range of axion masses.

hep-ex

First Results from Axion Haloscope at CAPP around 10.7 $μ$eV

The Center for Axion and Precision Physics research at the Institute for Basic Science is searching for axion dark matter using ultra-low temperature microwave resonators. We report the exclusion of the axion mass range 10.7126$-$10.7186 $μ$eV with near Kim-Shifman-Vainshtein-Zakharov (KSVZ) coupling sensitivity and the range 10.16$-$11.37 $μ$eV with about 9 times larger coupling at 90$\%$ confidence level. This is the first axion search result in these ranges. It is also the first with a resonator physical temperature of less than 40 mK.

hep-ex

First prototype of a biaxially textured YBa$_{2}$Cu$_{3}$O$_{7-x}$ microwave cavity in a high magnetic field for dark matter axion search

A high-quality factor microwave resonator in the presence of a strong magnetic field could have a wide range of applications, such as axion dark matter searches where the two aspects must coexist to enhance the experimental sensitivity. We introduce a polygon-shaped cavity design with bi-axially textured YBa$_{2}$Cu$_{3}$O$_{7-x}$ superconducting tapes covering the entire inner wall. Using a 12-sided polygon cavity, we obtain substantially improved quality factors of the TM$_{010}$ mode at 6.9 GHz at 4 K with respect to a copper cavity and observe no considerable degradation in the presence of magnetic fields up to 8 T. This corresponds to the first demonstration of practical applications of superconducting radio frequency technology for axion and other research areas requiring low loss in a strong magnetic field. We address the importance of the successful demonstration and discuss further improvements.

physics.ins-det

Characterization of a flux-driven Josephson parametric amplifier with near quantum-limited added noise for axion search experiments

The axion, a hypothetical elementary pseudoscalar, is expected to solve the strong CP problem of QCD and is also a promising candidate for dark matter. The most sensitive axion search experiments operate at millikelvin temperatures and hence rely on instrumentation that carries signals from a system at cryogenic temperatures to room temperature instrumentation. One of the biggest limiting factors affecting the parameter scanning speed of these detectors is the noise added by the components in the signal detection chain. Since the first amplifier in the chain limits the minimum noise, low-noise amplification is of paramount importance. This paper reports on the operation of a flux-driven Josephson parametric amplifier (JPA) operating at around 2.3 GHz with added noise approaching the quantum limit. The JPA was employed as a first stage amplifier in an experimental setting similar to the ones used in haloscope axion detectors. By operating the JPA at a gain of 19 dB and cascading it with two cryogenic amplifiers operating at 4 K, noise temperatures as low as 120 mK were achieved for the whole signal detection chain.

cond-mat.supr-con

Superconducting cavity in a high magnetic field

A high Q-factor microwave resonator in a high magnetic field could be used in a wide range of applications, especially for enhancing the scanning speed in axion dark matter research. In this letter, we introduce a polygon-shaped resonant cavity with commercial YBCO tapes covering the entire inner wall. We demonstrated that the maximum Q-factor (TM$_{010}$, 6.93 GHz) of the superconducting YBCO cavity was about 6 times higher than that of a copper cavity and showed no significant degradation up to 8 T at 4 K. This is the first indication of the possible applications of HTS technology to the research areas requiring low loss in a strong magnetic field at high radio frequencies.

physics.app-ph

Axion Dark Matter Research with IBS/CAPP

The axion, a consequence of the PQ mechanism, has been considered as the most elegant solution to the strong-CP problem and a compelling candidate for cold dark matter. The Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) was established on 16 October 2013 with a main objective to launch state of the art axion experiments in South Korea. Relying on the haloscope technique, our strategy is to run several experiments in parallel to explore a wide range of axion masses with sensitivities better than the QCD axion models. We utilize not only the advanced technologies, such as high-field large-volume superconducting (SC) magnets, ultra low temperature dilution refrigerators, and nearly quantum-limited noise amplifiers, but also some unique features solely developed at the Center, including high-quality SC resonant cavities surviving high magnetic fields and efficient cavity geometries to reach high-frequency regions. Our goal is to probe axion dark matter in the frequency range of 1-10 GHz in the first phase and then ultimately up to 25 GHz, even in a scenario where axions constitute only 10% of the local dark matter halo. In this report, the current status and future prospects of the experiments and R&D activities at IBS/CAPP are described.

physics.ins-det

Maintaining high Q-factor of superconducting YBa$_2$Cu$_3$O$_{7-x}$ microwave cavity in a high magnetic field

A high Q-factor microwave resonator in a high magnetic field could be of great use in a wide range of fields, from accelerator design to axion dark matter search. The natural choice of material for the superconducting cavity to be placed in a high field is a high temperature superconductor (HTS) with a high critical field. The deposition, however, of a high-quality, grain-aligned HTS film on a three-dimensional surface is technically challenging. We have fabricated a polygon-shaped resonant cavity with commercial YBa$_2$Cu$_3$O$_{7-x}$ (YBCO) tapes covering the entire inner wall and measured the Q-factor at 4 K at 6.93 GHz as a function of an external DC magnetic field. We demonstrated that the high Q-factor of the superconducting YBCO cavity showed no significant degradation from 1 T up to 8 T. This is the first indication of the possible applications of HTS technology to the research areas requiring a strong magnetic field at high radio frequencies.

physics.ins-det

Magnetoresistance in copper at high frequency and high magnetic fields

In halo dark matter axion search experiments, cylindrical microwave cavities are typically employed to detect signals from the axion-photon conversion. To enhance the conversion power and reduce the noise level, cavities are placed in strong solenoid magnetic fields at sufficiently low temperatures. Exploring high mass regions in cavity-based axion search experiments requires high frequency microwave cavities and thus understanding cavity properties at high frequencies in extreme conditions is deemed necessary. We present a study of the magnetoresistance of copper using a cavity with a resonant frequency of 12.9 GHz at the liquid helium temperature in magnetic fields up to 15 T utilizing a second generation high temperature superconducting magnet. The observations are interpreted to be consistent with the anomalous skin effect and size effect. This is the first measurement of magnetoresistance at a high frequency (> 10 GHz) in high magnetic fields (> 10 T).

physics.ins-det