arXiv ScienceSearch

arXiv subjects

Dong Ma

Publications and source records attributed to Dong Ma.

At least 19 recordsLinked to original sources

CultureVidBench: Benchmarking Cultural Understanding in Text-to-Video Generation

Text-to-video (T2V) generation models have advanced rapidly, yet their ability to represent diverse cultural contexts remains underexplored. Existing benchmarks mainly focus on perceptual quality, physical plausibility, and text-video alignment, but do not directly assess whether generated videos capture culturally specific objects, actions, rituals, visible text, or audio cues. We introduce CultureVidBench, a comprehensive benchmark for evaluating cultural understanding in T2V generation. CultureVidBench contains 1,000 curated prompts covering 12 countries, 6 continents, 8 cultural regions, and 14 cultural aspects organized into three categories: material culture, social practice & performance, and ritual & ceremony. Designed specifically for video generation, CultureVidBench emphasizes dynamic and multimodal cultural representation, including social interactions, ritual procedure, and culturally appropriate visible text and audio. We evaluate seven representative T2V models through human user studies and MLLM-based automatic assessment across cultural faithfulness, multimodal cultural rendering, semantic adherence, and perceptual quality. Results show that although current models achieve strong semantic adherence and visual quality, they often fail to faithfully capture fine-grained cultural details, particularly for underrepresented regions, rituals, and multimodal cultural cues.

cs.CV

Learning ECG Image Representations via Dual Physiological-Aware Alignments

Electrocardiograms (ECGs) are among the most widely used diagnostic tools for cardiovascular diseases, and a large amount of ECG data worldwide appears only in image form. However, most existing automated ECG analysis methods rely on access to raw signal recordings, limiting their applicability in real-world and resource-constrained settings. In this paper, we present ECG-Scan, a self-supervised framework for learning clinically generalized representations from ECG images through dual physiological-aware alignments: 1) Our approach optimizes image representation learning using multimodal contrastive alignment between image and gold-standard signal-text modalities. 2) We further integrate domain knowledge via soft-lead constraints, regularizing the reconstruction process and improving signal lead inter-consistency. Extensive benchmarking across multiple datasets and downstream tasks demonstrates that our image-based model achieves superior performance compared to existing image baselines and notably narrows the gap between ECG image and signal analysis. These results highlight the potential of self-supervised image modeling to unlock large-scale legacy ECG data and broaden access to automated cardiovascular diagnostics.

cs.LG

Wearable Foundation Models Should Go Beyond Static Encoders

Wearable foundation models (WFMs), trained on large volumes of data collected by affordable, always-on devices, have demonstrated strong performance on short-term, well-defined health monitoring tasks, including activity recognition, fitness tracking, and cardiovascular signal assessment. However, most existing WFMs primarily map short temporal windows to predefined labels via static encoders, emphasizing retrospective prediction rather than reasoning over evolving personal history, context, and future risk trajectories. As a result, they are poorly suited for modeling chronic, progressive, or episodic health conditions that unfold over weeks, months or years. Hence, we argue that WFMs must move beyond static encoders and be explicitly designed for longitudinal, anticipatory health reasoning. We identify three foundational shifts required to enable this transition: (1) Structurally rich data, which goes beyond isolated datasets or outcome-conditioned collection to integrated multimodal, long-term personal trajectories, and contextual metadata, ideally supported by open and interoperable data ecosystems; (2) Longitudinal-aware multimodal modeling, which prioritizes long-context inference, temporal abstraction, and personalization over cross-sectional or population-level prediction; and (3) Agentic inference systems, which move beyond static prediction to support planning, decision-making, and clinically grounded intervention under uncertainty. Together, these shifts reframe wearable health monitoring from retrospective signal interpretation toward continuous, anticipatory, and human-aligned health support.

cs.LG

PulseLM: A Foundation Dataset and Benchmark for PPG-Text Learning

Photoplethysmography (PPG) is a widely used non-invasive sensing modality for continuous cardiovascular and physiological monitoring across clinical, laboratory, and wearable settings. While existing PPG datasets support a broad range of downstream tasks, they typically provide supervision in the form of numerical measurements or task-specific labels, limiting their compatibility with language-based interfaces and multimodal foundation models. In this work, we introduce PulseLM, a large-scale PPG-text question-answering dataset that bridges raw PPG waveforms and natural language through a unified question-answering (QA) formulation. PulseLM aggregates PPG recordings from sixteen publicly available sources and harmonizes heterogeneous annotations into 12 downstream tasks. The dataset comprises over 1 million standardized 10-second PPG segments, associated with nearly 2.5 million question-answer pairs. We further define reproducible data pipeline, training, and evaluation protocols and establish baseline benchmarks using multimodal PPG-aware large language models. PulseLM provides a standardized foundation for studying language-grounded physiological inference, cross-dataset generalization, and scalable benchmarking of PPG-based multimodal models. We publicly release the dataset and code at https://huggingface.co/datasets/Manhph2211/PulseLM and https://github.com/manhph2211/PULSE-LM, respectively.

cs.CL

BAIT: Visual-illusion-inspired Privacy Preservation for Mobile Data Visualization

With the prevalence of mobile data visualizations, there have been growing concerns about their privacy risks, especially shoulder surfing attacks. Inspired by prior research on visual illusion, we propose BAIT, a novel approach to automatically generate privacy-preserving visualizations by stacking a decoy visualization over a given visualization. It allows visualization owners at proximity to clearly discern the original visualization and makes shoulder surfers at a distance be misled by the decoy visualization, by adjusting different visual channels of a decoy visualization (e.g., shape, position, tilt, size, color and spatial frequency). We explicitly model human perception effect at different viewing distances to optimize the decoy visualization design. Privacy-preserving examples and two in-depth user studies demonstrate the effectiveness of BAIT in both controlled lab study and real-world scenarios.

cs.HC

Device-Guided Music Transfer

Device-guided music transfer adapts playback across unseen devices for users who lack them. Existing methods mainly focus on modifying the timbre, rhythm, harmony, or instrumentation to mimic genres or artists, overlooking the diverse hardware properties of the playback device (i.e., speaker). Therefore, we propose DeMT, which processes a speaker's frequency response curve as a line graph using a vision-language model to extract device embeddings. These embeddings then condition a hybrid transformer via feature-wise linear modulation. Fine-tuned on a self-collected dataset, DeMT enables effective speaker-style transfer and robust few-shot adaptation for unseen devices, supporting applications like device-style augmentation and quality enhancement.

cs.SD

Interpretable Multimodal Zero-Shot ECG Diagnosis via Structured Clinical Knowledge Alignment

Electrocardiogram (ECG) interpretation is essential for cardiovascular disease diagnosis, but current automated systems often struggle with transparency and generalization to unseen conditions. To address this, we introduce ZETA, a zero-shot multimodal framework designed for interpretable ECG diagnosis aligned with clinical workflows. ZETA uniquely compares ECG signals against structured positive and negative clinical observations, which are curated through an LLM-assisted, expert-validated process, thereby mimicking differential diagnosis. Our approach leverages a pre-trained multimodal model to align ECG and text embeddings without disease-specific fine-tuning. Empirical evaluations demonstrate ZETA's competitive zero-shot classification performance and, importantly, provide qualitative and quantitative evidence of enhanced interpretability, grounding predictions in specific, clinically relevant positive and negative diagnostic features. ZETA underscores the potential of aligning ECG analysis with structured clinical knowledge for building more transparent, generalizable, and trustworthy AI diagnostic systems. We will release the curated observation dataset and code to facilitate future research.

cs.LG

A Survey of Earable Technology: Trends, Tools, and the Road Ahead

Earable devices, wearables positioned in or around the ear, are undergoing a rapid transformation from audio-centric accessories into multifunctional systems for interaction, contextual awareness, and health monitoring. This evolution is driven by commercial trends emphasizing sensor integration and by a surge of academic interest exploring novel sensing capabilities. Building on the foundation established by earlier surveys, this work presents a timely and comprehensive review of earable research published since 2022. We analyze over one hundred recent studies to characterize this shifting research landscape, identify emerging applications and sensing modalities, and assess progress relative to prior efforts. In doing so, we address three core questions: how has earable research evolved in recent years, what enabling resources are now available, and what opportunities remain for future exploration. Through this survey, we aim to provide both a retrospective and forward-looking view of earable technology as a rapidly expanding frontier in ubiquitous computing. In particular, this review reveals that over the past three years, researchers have discovered a variety of novel sensing principles, developed many new earable sensing applications, enhanced the accuracy of existing sensing tasks, and created substantial new resources to advance research in the field. Based on this, we further discuss open challenges and propose future directions for the next phase of earable research.

cs.HC

The Promise of Spiking Neural Networks for Ubiquitous Computing: A Survey and New Perspectives

Spiking neural networks (SNNs) have emerged as a class of bio -inspired networks that leverage sparse, event-driven signaling to achieve low-power computation while inherently modeling temporal dynamics. Such characteristics align closely with the demands of ubiquitous computing systems, which often operate on resource-constrained devices while continuously monitoring and processing time-series sensor data. Despite their unique and promising features, SNNs have received limited attention and remain underexplored (or at least, under-adopted) within the ubiquitous computing community. To address this gap, this paper first introduces the core components of SNNs, both in terms of models and training mechanisms. It then presents a systematic survey of 76 SNN-based studies focused on time-series data analysis, categorizing them into six key application domains. For each domain, we summarize relevant works and subsequent advancements, distill core insights, and highlight key takeaways for researchers and practitioners. To facilitate hands-on experimentation, we also provide a comprehensive review of current software frameworks and neuromorphic hardware platforms, detailing their capabilities and specifications, and then offering tailored recommendations for selecting development tools based on specific application needs. Finally, we identify prevailing challenges within each application domain and propose future research directions that need be explored in ubiquitous community. Our survey highlights the transformative potential of SNNs in enabling energy-efficient ubiquitous sensing across diverse application domains, while also serving as an essential introduction for researchers looking to enter this emerging field.

cs.NE

Q-Heart: ECG Question Answering via Knowledge-Informed Multimodal LLMs

Electrocardiography (ECG) offers critical cardiovascular insights, such as identifying arrhythmias and myocardial ischemia, but enabling automated systems to answer complex clinical questions directly from ECG signals (ECG-QA) remains a significant challenge. Current approaches often lack robust multimodal reasoning capabilities or rely on generic architectures ill-suited for the nuances of physiological signals. We introduce Q-Heart, a novel multimodal framework designed to bridge this gap. Q-Heart leverages a powerful, adapted ECG encoder and integrates its representations with textual information via a specialized ECG-aware transformer-based mapping layer. Furthermore, Q-Heart leverages dynamic prompting and retrieval of relevant historical clinical reports to guide tuning the language model toward knowledge-aware ECG reasoning. Extensive evaluations on the benchmark ECG-QA dataset show Q-Heart achieves state-of-the-art performance, outperforming existing methods by a 4% improvement in exact match accuracy. Our work demonstrates the effectiveness of combining domain-specific architectural adaptations with knowledge-augmented LLM instruction tuning for complex physiological ECG analysis, paving the way for more capable and potentially interpretable clinical patient care systems.

eess.SP

EmbodiTTA: Resource-Efficient Test-Time Adaptation for Embodied Visual Systems

Continual Test-time adaptation (CTTA) continuously adapts the deployed model on every incoming batch of data. While achieving optimal accuracy, existing CTTA approaches present poor real-world applicability on resource-constrained edge devices, due to the substantial memory overhead and energy consumption. In this work, we first introduce a novel paradigm -- on-demand TTA -- which triggers adaptation only when a significant domain shift is detected. Then, we present OD-TTA, an on-demand TTA framework for accurate and efficient adaptation on edge devices. OD-TTA comprises three innovative techniques: 1) a lightweight domain shift detection mechanism to activate TTA only when it is needed, drastically reducing the overall computation overhead, 2) a source domain selection module that chooses an appropriate source model for adaptation, ensuring high and robust accuracy, 3) a decoupled Batch Normalization (BN) update scheme to enable memory-efficient adaptation with small batch sizes. Extensive experiments show that OD-TTA achieves comparable and even better performance while reducing the energy and computation overhead remarkably, making TTA a practical reality.

cs.LG

Reliable Physiological Monitoring on the Wrist Using Generative Deep Learning to Address Poor Skin-Sensor Contact

Photoplethysmography (PPG) is a widely adopted, non-invasive technique for monitoring cardiovascular health and physiological parameters in both consumer and clinical settings. While motion artifacts in dynamic environments have been extensively studied, suboptimal skin-sensor contact in sedentary conditions - a critical yet underexplored issue - can distort PPG waveform morphology, leading to the loss or misalignment of key features and compromising sensing accuracy. In this work, we propose CP-PPG, a novel framework that transforms Contact Pressure-distorted PPG signals into high-fidelity waveforms with ideal morphology. CP-PPG integrates a custom data collection protocol, a carefully designed signal processing pipeline, and a novel deep adversarial model trained with a custom PPG-aware loss function. We validated CP-PPG through comprehensive evaluations, including 1) morphology transformation performance on our self-collected dataset, 2) downstream physiological monitoring performance on public datasets, and 3) in-the-wild study. Extensive experiments demonstrate substantial and consistent improvements in signal fidelity (Mean Absolute Error: 0.09, 40% improvement over the original signal) as well as downstream performance across all evaluations in Heart Rate (HR), Heart Rate Variability (HRV), Respiration Rate (RR), and Blood Pressure (BP) estimation (on average, 21% improvement in HR; 41-46% in HRV; 6% in RR; and 4-5% in BP). These findings highlight the critical importance of addressing skin-sensor contact issues to enhance the reliability and effectiveness of PPG-based physiological monitoring. CP-PPG thus holds significant potential to improve the accuracy of wearable health technologies in clinical and consumer applications.

cs.HC

Boosting Masked ECG-Text Auto-Encoders as Discriminative Learners

The accurate interpretation of Electrocardiogram (ECG) signals is pivotal for diagnosing cardiovascular diseases. Integrating ECG signals with accompanying textual reports further holds immense potential to enhance clinical diagnostics by combining physiological data and qualitative insights. However, this integration faces significant challenges due to inherent modality disparities and the scarcity of labeled data for robust cross-modal learning. To address these obstacles, we propose D-BETA, a novel framework that pre-trains ECG and text data using a contrastive masked auto-encoder architecture. D-BETA uniquely combines the strengths of generative with boosted discriminative capabilities to achieve robust cross-modal representations. This is accomplished through masked modality modeling, specialized loss functions, and an improved negative sampling strategy tailored for cross-modal alignment. Extensive experiments on five public datasets across diverse downstream tasks demonstrate that D-BETA significantly outperforms existing methods, achieving an average AUC improvement of 15% in linear probing with only one percent of training data and 2% in zero-shot performance without requiring training data over state-of-the-art models. These results highlight the effectiveness of D-BETA, underscoring its potential to advance automated clinical diagnostics through multi-modal representations. Our sample code and checkpoint are made available at https://github.com/manhph2211/D-BETA.

cs.LG

RespEar: Earable-Based Robust Respiratory Rate Monitoring

Respiratory rate (RR) monitoring is integral to understanding physical and mental health and tracking fitness. Existing studies have demonstrated the feasibility of RR monitoring under specific user conditions (e.g., while remaining still, or while breathing heavily). Yet, performing accurate, continuous and non-obtrusive RR monitoring across diverse daily routines and activities remains challenging. In this work, we present RespEar, an earable-based system for robust RR monitoring. By leveraging the unique properties of in-ear microphones in earbuds, RespEar enables the use of Respiratory Sinus Arrhythmia (RSA) and Locomotor Respiratory Coupling (LRC), physiological couplings between cardiovascular activity, gait and respiration, to indirectly determine RR. This effectively addresses the challenges posed by the almost imperceptible breathing signals under daily activities. We further propose a suite of meticulously crafted signal processing schemes to improve RR estimation accuracy and robustness. With data collected from 18 subjects over 8 activities, RespEar measures RR with a mean absolute error (MAE) of 1.48 breaths per minutes (BPM) and a mean absolute percent error (MAPE) of 9.12% in sedentary conditions, and a MAE of 2.28 BPM and a MAPE of 11.04% in active conditions, respectively, which is unprecedented for a method capable of generalizing across conditions with a single modality.

cs.HC

DiTMoS: Delving into Diverse Tiny-Model Selection on Microcontrollers

Enabling efficient and accurate deep neural network (DNN) inference on microcontrollers is non-trivial due to the constrained on-chip resources. Current methodologies primarily focus on compressing larger models yet at the expense of model accuracy. In this paper, we rethink the problem from the inverse perspective by constructing small/weak models directly and improving their accuracy. Thus, we introduce DiTMoS, a novel DNN training and inference framework with a selector-classifiers architecture, where the selector routes each input sample to the appropriate classifier for classification. DiTMoS is grounded on a key insight: a composition of weak models can exhibit high diversity and the union of them can significantly boost the accuracy upper bound. To approach the upper bound, DiTMoS introduces three strategies including diverse training data splitting to increase the classifiers' diversity, adversarial selector-classifiers training to ensure synergistic interactions thereby maximizing their complementarity, and heterogeneous feature aggregation to improve the capacity of classifiers. We further propose a network slicing technique to alleviate the extra memory overhead incurred by feature aggregation. We deploy DiTMoS on the Neucleo STM32F767ZI board and evaluate it based on three time-series datasets for human activity recognition, keywords spotting, and emotion recognition, respectively. The experiment results manifest that: (a) DiTMoS achieves up to 13.4% accuracy improvement compared to the best baseline; (b) network slicing almost completely eliminates the memory overhead incurred by feature aggregation with a marginal increase of latency.

cs.LG

UR2M: Uncertainty and Resource-Aware Event Detection on Microcontrollers

Traditional machine learning techniques are prone to generating inaccurate predictions when confronted with shifts in the distribution of data between the training and testing phases. This vulnerability can lead to severe consequences, especially in applications such as mobile healthcare. Uncertainty estimation has the potential to mitigate this issue by assessing the reliability of a model's output. However, existing uncertainty estimation techniques often require substantial computational resources and memory, making them impractical for implementation on microcontrollers (MCUs). This limitation hinders the feasibility of many important on-device wearable event detection (WED) applications, such as heart attack detection. In this paper, we present UR2M, a novel Uncertainty and Resource-aware event detection framework for MCUs. Specifically, we (i) develop an uncertainty-aware WED based on evidential theory for accurate event detection and reliable uncertainty estimation; (ii) introduce a cascade ML framework to achieve efficient model inference via early exits, by sharing shallower model layers among different event models; (iii) optimize the deployment of the model and MCU library for system efficiency. We conducted extensive experiments and compared UR2M to traditional uncertainty baselines using three wearable datasets. Our results demonstrate that UR2M achieves up to 864% faster inference speed, 857% energy-saving for uncertainty estimation, 55% memory saving on two popular MCUs, and a 22% improvement in uncertainty quantification performance. UR2M can be deployed on a wide range of MCUs, significantly expanding real-time and reliable WED applications.

cs.LG

Ultra-small topological spin textures with size of 1.3nm at above room temperature in Fe78Si9B13 amorphous alloy

Topologically protected spin textures, such as skyrmions1,2 and vortices3,4, are robust against perturbations, serving as the building blocks for a range of topological devices5-9. In order to implement these topological devices, it is necessary to find ultra-small topological spin textures at room temperature, because small size implies the higher topological charge density, stronger signal of topological transport10,11 and the higher memory density or integration for topological quantum devices5-9. However, finding ultra-small topological spin textures at high temperatures is still a great challenge up to now. Here we find ultra-small topological spin textures in Fe78Si9B13 amorphous alloy. We measured a large topological Hall effect (THE) up to above room temperature, indicating the existence of highly densed and ultra-small topological spin textures in the samples. Further measurements by small-angle neutron scattering (SANS) reveal that the average size of ultra-small magnetic texture is around 1.3nm. Our Monte Carlo simulations show that such ultra-small spin texture is topologically equivalent to skyrmions, which originate from competing frustration and Dzyaloshinskii-Moriya interaction12,13 coming from amorphous structure14-17. Taking a single topological spin texture as one bit and ignoring the distance between them, we evaluated the ideal memory density of Fe78Si9B13, which reaches up to 4.44*104 gigabits (43.4 TB) per in2 and is 2 times of the value of GdRu2Si218 at 5K. More important, such high memory density can be obtained at above room temperature, which is 4 orders of magnitude larger than the value of other materials at the same temperature. These findings provide a unique candidate for magnetic memory devices with ultra-high density.

cond-mat.mtrl-sci

Channelized analog microwave short-time Fourier transform in the optical domain with improved measurement performance

In this article, analog microwave short-time Fourier transform (STFT) with improved measurement performance is implemented in the optical domain by employing stimulated Brillouin scattering (SBS) and channelization. By jointly using three optical frequency combs and filter- and SBS-based frequency-to-time mapping (FTTM), the time-frequency information of the signal under test (SUT) in different frequency intervals is measured in different channels. Then, by using the channel label introduced through subcarriers after photodetection, the obtained low-speed electrical pulses in different channels mixed in the time domain are distinguished and the time-frequency information of the SUT in different channels is respectively obtained and spliced to implement the STFT. For the first time, channelization measurement technology is introduced in the STFT system based on frequency sweeping and FTTM, greatly reducing the frequency-sweep range of the required frequency-sweep signal to the analysis bandwidth divided by the number of channels. In addition, channelization can also be used to improve the time and frequency resolution of the STFT system. A proof-of-concept experiment is performed. 12-GHz and 10-GHz analysis bandwidth is implemented by using a 4-GHz frequency-sweep signal and 3 channels and a 2-GHz frequency-sweep signal and 5 channels. Measurement performance improvement is also demonstrated.

eess.SP