arXiv Science⌕ Search

arXiv subjects

Dong Liang

Publications and source records attributed to Dong Liang.

At least 91 records · Page 5Linked to original sources

A Mini Immersed Finite Element Method for Two-Phase Stokes Problems on Cartesian Meshes

This paper presents a mini immersed finite element (IFE) method for solving two- and three-dimensional two-phase Stokes problems on Cartesian meshes. The IFE space is constructed from the conventional mini element, with shape functions modified on interface elements according to interface jump conditions, while keeping the degrees of freedom unchanged. Both discontinuous viscosity coefficients and surface forces are taken into account in the construction. The interface is approximated using discrete level set functions, and explicit formulas for IFE basis functions and correction functions are derived, facilitating ease of implementation.The inf-sup stability and the optimal a priori error estimate of the IFE method, along with the optimal approximation capabilities of the IFE space, are derived rigorously, with constants that are independent of the mesh size and the manner in which the interface intersects the mesh, but may depend on the discontinuous viscosity coefficients. Additionally, it is proved that the condition number has the usual bound independent of the interface. Numerical experiments are provided to confirm the theoretical results.

math.NA↗

Sequential-Scanning Dual-Energy CT Imaging Using High Temporal Resolution Image Reconstruction and Error-Compensated Material Basis Image Generation

Dual-energy computed tomography (DECT) has been widely used to obtain quantitative elemental composition of imaged subjects for personalized and precise medical diagnosis. Compared with DECT leveraging advanced X-ray source and/or detector technologies, the use of the sequential-scanning data acquisition scheme to implement DECT may make a broader impact on clinical practice because this scheme requires no specialized hardware designs and can be directly implemented into conventional CT systems. However, since the concentration of iodinated contrast agent in the imaged subject varies over time, sequentially scanned data sets acquired at two tube potentials are temporally inconsistent. As existing material basis image reconstruction approaches assume that the data sets acquired at two tube potentials are temporally consistent, the violation of this assumption results in inaccurate quantification of material concentration. In this work, we developed sequential-scanning DECT imaging using high temporal resolution image reconstruction and error-compensated material basis image generation, ACCELERATION in short, to address the technical challenge induced by temporal inconsistency of sequentially scanned data sets and improve quantification accuracy of material concentration in sequential-scanning DECT. ACCELERATION has been validated and evaluated using numerical simulation data sets generated from clinical human subject exams and experimental human subject studies. Results demonstrated the improvement of quantification accuracy and image quality using ACCELERATION.

physics.med-ph↗

Pediatric TSC-Related Epilepsy Classification from Clinical MR Images Using Quantum Neural Network

Tuberous sclerosis complex (TSC) manifests as a multisystem disorder with significant neurological implications. This study addresses the critical need for robust classification models tailored to TSC in pediatric patients, introducing QResNet,a novel deep learning model seamlessly integrating conventional convolutional neural networks with quantum neural networks. The model incorporates a two-layer quantum layer (QL), comprising ZZFeatureMap and Ansatz layers, strategically designed for processing classical data within a quantum framework. A comprehensive evaluation, demonstrates the superior performance of QResNet in TSC MRI image classification compared to conventional 3D-ResNet models. These compelling findings underscore the potential of quantum computing to revolutionize medical imaging and diagnostics.Remarkably, this method surpasses conventional CNNs in accuracy and Area Under the Curve (AUC) metrics with the current dataset. Future research endeavors may focus on exploring the scalability and practical implementation of quantum algorithms in real-world medical imaging scenarios.

eess.IV↗

MR Optimized Reconstruction of Simultaneous Multi-Slice Imaging Using Diffusion Model

Diffusion model has been successfully applied to MRI reconstruction, including single and multi-coil acquisition of MRI data. Simultaneous multi-slice imaging (SMS), as a method for accelerating MR acquisition, can significantly reduce scanning time, but further optimization of reconstruction results is still possible. In order to optimize the reconstruction of SMS, we proposed a method to use diffusion model based on slice-GRAPPA and SPIRiT method. approach: Specifically, our method characterizes the prior distribution of SMS data by score matching and characterizes the k-space redundant prior between coils and slices based on self-consistency. With the utilization of diffusion model, we achieved better reconstruction results.The application of diffusion model can further reduce the scanning time of MRI without compromising image quality, making it more advantageous for clinical application

eess.IV↗

AquilaMoE: Efficient Training for MoE Models with Scale-Up and Scale-Out Strategies

In recent years, with the rapid application of large language models across various fields, the scale of these models has gradually increased, and the resources required for their pre-training have grown exponentially. Training an LLM from scratch will cost a lot of computation resources while scaling up from a smaller model is a more efficient approach and has thus attracted significant attention. In this paper, we present AquilaMoE, a cutting-edge bilingual 8*16B Mixture of Experts (MoE) language model that has 8 experts with 16 billion parameters each and is developed using an innovative training methodology called EfficientScale. This approach optimizes performance while minimizing data requirements through a two-stage process. The first stage, termed Scale-Up, initializes the larger model with weights from a pre-trained smaller model, enabling substantial knowledge transfer and continuous pretraining with significantly less data. The second stage, Scale-Out, uses a pre-trained dense model to initialize the MoE experts, further enhancing knowledge transfer and performance. Extensive validation experiments on 1.8B and 7B models compared various initialization schemes, achieving models that maintain and reduce loss during continuous pretraining. Utilizing the optimal scheme, we successfully trained a 16B model and subsequently the 8*16B AquilaMoE model, demonstrating significant improvements in performance and training efficiency.

cs.CL↗

ACCELERATION: Sequentially-scanning DECT Imaging Using High Temporal Resolution Image Reconstruction And Temporal Extrapolation

Dual-energy computed tomography (DECT) has been widely used to obtain quantitative elemental composition of imaged subjects for personalized and precise medical diagnosis. Compared with existing high-end DECT leveraging advanced X-ray source and/or detector technologies, the use of the sequentially-scanning data acquisition scheme to implement DECT may make broader impact on clinical practice because this scheme requires no specialized hardware designs. However, since the concentration of iodinated contrast agent in the imaged subject varies over time, sequentially-scanned data sets acquired at two tube potentials are temporally inconsistent. As existing material decomposition approaches for DECT assume that the data sets acquired at two tube potentials are temporally consistent, the violation of this assumption results in inaccurate quantification accuracy of iodine concentration. In this work, we developed a technique to achieve sequentially-scanning DECT imaging using high temporal resolution image reconstruction and temporal extrapolation, ACCELERATION in short, to address the technical challenge induced by temporal inconsistency of sequentially-scanned data sets and improve iodine quantification accuracy in sequentially-scanning DECT. ACCELERATION has been validated and evaluated using numerical simulation data sets generated from clinical human subject exams. Results demonstrated the improvement of iodine quantification accuracy using ACCELERATION.

physics.med-ph↗

Joint PET-MRI Reconstruction with Diffusion Stochastic Differential Model

PET suffers from a low signal-to-noise ratio. Meanwhile, the k-space data acquisition process in MRI is time-consuming by PET-MRI systems. We aim to accelerate MRI and improve PET image quality. This paper proposed a novel joint reconstruction model by diffusion stochastic differential equations based on learning the joint probability distribution of PET and MRI. Compare the results underscore the qualitative and quantitative improvements our model brings to PET and MRI reconstruction, surpassing the current state-of-the-art methodologies. Joint PET-MRI reconstruction is a challenge in the PET-MRI system. This studies focused on the relationship extends beyond edges. In this study, PET is generated from MRI by learning joint probability distribution as the relationship.

cs.CV↗

LINEAR: Learning Implicit Neural Representation With Explicit Physical Priors for Accelerated Quantitative T1rho Mapping

Quantitative T1rho mapping has shown promise in clinical and research studies. However, it suffers from long scan times. Deep learning-based techniques have been successfully applied in accelerated quantitative MR parameter mapping. However, most methods require fully-sampled training dataset, which is impractical in the clinic. In this study, a novel subject-specific unsupervised method based on the implicit neural representation is proposed to reconstruct T1rho-weighted images from highly undersampled k-space data, which only takes spatiotemporal coordinates as the input. Specifically, the proposed method learned a implicit neural representation of the MR images driven by two explicit priors from the physical model of T1rho mapping, including the signal relaxation prior and self-consistency of k-t space data prior. The proposed method was verified using both retrospective and prospective undersampled k-space data. Experiment results demonstrate that LINEAR achieves a high acceleration factor up to 14, and outperforms the state-of-the-art methods in terms of suppressing artifacts and achieving the lowest error.

eess.IV↗

Generalized Robust Fundus Photography-based Vision Loss Estimation for High Myopia

High myopia significantly increases the risk of irreversible vision loss. Traditional perimetry-based visual field (VF) assessment provides systematic quantification of visual loss but it is subjective and time-consuming. Consequently, machine learning models utilizing fundus photographs to estimate VF have emerged as promising alternatives. However, due to the high variability and the limited availability of VF data, existing VF estimation models fail to generalize well, particularly when facing out-of-distribution data across diverse centers and populations. To tackle this challenge, we propose a novel, parameter-efficient framework to enhance the generalized robustness of VF estimation on both in- and out-of-distribution data. Specifically, we design a Refinement-by-Denoising (RED) module for feature refinement and adaptation from pretrained vision models, aiming to learn high-entropy feature representations and to mitigate the domain gap effectively and efficiently. Through independent validation on two distinct real-world datasets from separate centers, our method significantly outperforms existing approaches in RMSE, MAE and correlation coefficient for both internal and external validation. Our proposed framework benefits both in- and out-of-distribution VF estimation, offering significant clinical implications and potential utility in real-world ophthalmic practices.

cs.CV↗

Pathformer3D: A 3D Scanpath Transformer for 360° Images

Scanpath prediction in 360° images can help realize rapid rendering and better user interaction in Virtual/Augmented Reality applications. However, existing scanpath prediction models for 360° images execute scanpath prediction on 2D equirectangular projection plane, which always result in big computation error owing to the 2D plane's distortion and coordinate discontinuity. In this work, we perform scanpath prediction for 360° images in 3D spherical coordinate system and proposed a novel 3D scanpath Transformer named Pathformer3D. Specifically, a 3D Transformer encoder is first used to extract 3D contextual feature representation for the 360° image. Then, the contextual feature representation and historical fixation information are input into a Transformer decoder to output current time step's fixation embedding, where the self-attention module is used to imitate the visual working memory mechanism of human visual system and directly model the time dependencies among the fixations. Finally, a 3D Gaussian distribution is learned from each fixation embedding, from which the fixation position can be sampled. Evaluation on four panoramic eye-tracking datasets demonstrates that Pathformer3D outperforms the current state-of-the-art methods. Code is available at https://github.com/lsztzp/Pathformer3D .

cs.CV↗

Joint Diffusion: Mutual Consistency-Driven Diffusion Model for PET-MRI Co-Reconstruction

Positron Emission Tomography and Magnetic Resonance Imaging (PET-MRI) systems can obtain functional and anatomical scans. PET suffers from a low signal-to-noise ratio. Meanwhile, the k-space data acquisition process in MRI is time-consuming. The study aims to accelerate MRI and enhance PET image quality. Conventional approaches involve the separate reconstruction of each modality within PET-MRI systems. However, there exists complementary information among multi-modal images. The complementary information can contribute to image reconstruction. In this study, we propose a novel PET-MRI joint reconstruction model employing a mutual consistency-driven diffusion mode, namely MC-Diffusion. MC-Diffusion learns the joint probability distribution of PET and MRI for utilizing complementary information. We conducted a series of contrast experiments about LPLS, Joint ISAT-net and MC-Diffusion by the ADNI dataset. The results underscore the qualitative and quantitative improvements achieved by MC-Diffusion, surpassing the state-of-the-art method.

eess.IV↗

Relative Difficulty Distillation for Semantic Segmentation

Current knowledge distillation (KD) methods primarily focus on transferring various structured knowledge and designing corresponding optimization goals to encourage the student network to imitate the output of the teacher network. However, introducing too many additional optimization objectives may lead to unstable training, such as gradient conflicts. Moreover, these methods ignored the guidelines of relative learning difficulty between the teacher and student networks. Inspired by human cognitive science, in this paper, we redefine knowledge from a new perspective -- the student and teacher networks' relative difficulty of samples, and propose a pixel-level KD paradigm for semantic segmentation named Relative Difficulty Distillation (RDD). We propose a two-stage RDD framework: Teacher-Full Evaluated RDD (TFE-RDD) and Teacher-Student Evaluated RDD (TSE-RDD). RDD allows the teacher network to provide effective guidance on learning focus without additional optimization goals, thus avoiding adjusting learning weights for multiple losses. Extensive experimental evaluations using a general distillation loss function on popular datasets such as Cityscapes, CamVid, Pascal VOC, and ADE20k demonstrate the effectiveness of RDD against state-of-the-art KD methods. Additionally, our research showcases that RDD can integrate with existing KD methods to improve their upper performance bound.

cs.CV↗

Fast Sampling for Linear Inverse Problems of Vectors and Tensors using Multilinear Extensions

This paper studies the problem of sampling vector and tensor signals, which is the process of choosing sites in vectors and tensors to place sensors for better recovery. A small core tensor and multiple factor matrices can be used to sparsely represent a dense higher-order tensor within a linear model. Using this linear model, one can effectively recover the whole signals from a limited number of measurements by solving linear inverse problems (LIPs). By providing the closed-form expressions of multilinear extensions for the frame potential of pruned matrices, we develop an algorithm named fast Frank-Wolfe algorithm (FFW) for sampling vectors and tensors with low complexity. We provide the approximation factor of our proposed algorithm for the factor matrices that are non-orthogonal and have elements of the same sign in each row. Moreover, we conduct experiments to verify the higher performance and lower complexity of our proposed algorithm for general factor matrix. Finally, we demonstrate that sampling by FFW and reconstruction by least squares methods yield better results for image data compared to convCNP completion with random sampling.

math.OC↗

Synthesizing PET images from High-field and Ultra-high-field MR images Using Joint Diffusion Attention Model

MRI and PET are crucial diagnostic tools for brain diseases, as they provide complementary information on brain structure and function. However, PET scanning is costly and involves radioactive exposure, resulting in a lack of PET. Moreover, simultaneous PET and MRI at ultra-high-field are currently hardly infeasible. Ultra-high-field imaging has unquestionably proven valuable in both clinical and academic settings, especially in the field of cognitive neuroimaging. These motivate us to propose a method for synthetic PET from high-filed MRI and ultra-high-field MRI. From a statistical perspective, the joint probability distribution (JPD) is the most direct and fundamental means of portraying the correlation between PET and MRI. This paper proposes a novel joint diffusion attention model which has the joint probability distribution and attention strategy, named JDAM. JDAM has a diffusion process and a sampling process. The diffusion process involves the gradual diffusion of PET to Gaussian noise by adding Gaussian noise, while MRI remains fixed. JPD of MRI and noise-added PET was learned in the diffusion process. The sampling process is a predictor-corrector. PET images were generated from MRI by JPD of MRI and noise-added PET. The predictor is a reverse diffusion process and the corrector is Langevin dynamics. Experimental results on the public Alzheimer's Disease Neuroimaging Initiative (ADNI) dataset demonstrate that the proposed method outperforms state-of-the-art CycleGAN for high-field MRI (3T MRI). Finally, synthetic PET images from the ultra-high-field (5T MRI and 7T MRI) be attempted, providing a possibility for ultra-high-field PET-MRI imaging.

cs.LG↗

Diff-DTI: Fast Diffusion Tensor Imaging Using A Feature-Enhanced Joint Diffusion Model

Magnetic resonance diffusion tensor imaging (DTI) is a critical tool for neural disease diagnosis. However, long scan time greatly hinders the widespread clinical use of DTI. To accelerate image acquisition, a feature-enhanced joint diffusion model (Diff-DTI) is proposed to obtain accurate DTI parameter maps from a limited number of diffusion-weighted images (DWIs). Diff-DTI introduces a joint diffusion model that directly learns the joint probability distribution of DWIs with DTI parametric maps for conditional generation. Additionally, a feature enhancement fusion mechanism (FEFM) is designed and incorporated into the generative process of Diff-DTI to preserve fine structures in the generated DTI maps. A comprehensive evaluation of the performance of Diff-DTI was conducted on the Human Connectome Project dataset. The results demonstrate that Diff-DTI outperforms existing state-of-the-art fast DTI imaging methods in terms of visual quality and quantitative metrics. Furthermore, Diff-DTI has shown the ability to produce high-fidelity DTI maps with only three DWIs, thus overcoming the requirement of a minimum of six DWIs for DTI.

eess.IV↗

Scaling User Modeling: Large-scale Online User Representations for Ads Personalization in Meta

Effective user representations are pivotal in personalized advertising. However, stringent constraints on training throughput, serving latency, and memory, often limit the complexity and input feature set of online ads ranking models. This challenge is magnified in extensive systems like Meta's, which encompass hundreds of models with diverse specifications, rendering the tailoring of user representation learning for each model impractical. To address these challenges, we present Scaling User Modeling (SUM), a framework widely deployed in Meta's ads ranking system, designed to facilitate efficient and scalable sharing of online user representation across hundreds of ads models. SUM leverages a few designated upstream user models to synthesize user embeddings from massive amounts of user features with advanced modeling techniques. These embeddings then serve as inputs to downstream online ads ranking models, promoting efficient representation sharing. To adapt to the dynamic nature of user features and ensure embedding freshness, we designed SUM Online Asynchronous Platform (SOAP), a latency free online serving system complemented with model freshness and embedding stabilization, which enables frequent user model updates and online inference of user embeddings upon each user request. We share our hands-on deployment experiences for the SUM framework and validate its superiority through comprehensive experiments. To date, SUM has been launched to hundreds of ads ranking models in Meta, processing hundreds of billions of user requests daily, yielding significant online metric gains and improved infrastructure efficiency.

cs.IR↗

DP-MDM: Detail-Preserving MR Reconstruction via Multiple Diffusion Models

Detail features of magnetic resonance images play a cru-cial role in accurate medical diagnosis and treatment, as they capture subtle changes that pose challenges for doc-tors when performing precise judgments. However, the widely utilized naive diffusion model has limitations, as it fails to accurately capture more intricate details. To en-hance the quality of MRI reconstruction, we propose a comprehensive detail-preserving reconstruction method using multiple diffusion models to extract structure and detail features in k-space domain instead of image do-main. Moreover, virtual binary modal masks are utilized to refine the range of values in k-space data through highly adaptive center windows, which allows the model to focus its attention more efficiently. Last but not least, an inverted pyramid structure is employed, where the top-down image information gradually decreases, ena-bling a cascade representation. The framework effective-ly represents multi-scale sampled data, taking into ac-count the sparsity of the inverted pyramid architecture, and utilizes cascade training data distribution to repre-sent multi-scale data. Through a step-by-step refinement approach, the method refines the approximation of de-tails. Finally, the proposed method was evaluated by con-ducting experiments on clinical and public datasets. The results demonstrate that the proposed method outper-forms other methods.

cs.CV↗

SPIRiT-Diffusion: Self-Consistency Driven Diffusion Model for Accelerated MRI

Diffusion models have emerged as a leading methodology for image generation and have proven successful in the realm of magnetic resonance imaging (MRI) reconstruction. However, existing reconstruction methods based on diffusion models are primarily formulated in the image domain, making the reconstruction quality susceptible to inaccuracies in coil sensitivity maps (CSMs). k-space interpolation methods can effectively address this issue but conventional diffusion models are not readily applicable in k-space interpolation. To overcome this challenge, we introduce a novel approach called SPIRiT-Diffusion, which is a diffusion model for k-space interpolation inspired by the iterative self-consistent SPIRiT method. Specifically, we utilize the iterative solver of the self-consistent term (i.e., k-space physical prior) in SPIRiT to formulate a novel stochastic differential equation (SDE) governing the diffusion process. Subsequently, k-space data can be interpolated by executing the diffusion process. This innovative approach highlights the optimization model's role in designing the SDE in diffusion models, enabling the diffusion process to align closely with the physics inherent in the optimization model, a concept referred to as model-driven diffusion. We evaluated the proposed SPIRiT-Diffusion method using a 3D joint intracranial and carotid vessel wall imaging dataset. The results convincingly demonstrate its superiority over image-domain reconstruction methods, achieving high reconstruction quality even at a substantial acceleration rate of 10.

cs.CV↗