arXiv ScienceSearch

arXiv subjects

Dominik Obrist

Publications and source records attributed to Dominik Obrist.

5 recordsLinked to original sources

Comparative Evaluation of Carotid Artery Hemodynamics: Patient-Specific CFD Simulations vs. 4D flow MRI

Wall shear stress (WSS) is implicated in carotid atherosclerosis, and 4D flow MRI offers a non-invasive route to its estimation, but the agreement of MRI-derived plaque-surface WSS with computational fluid dynamics (CFD) has not been quantified in a large cohort. We compared peak-systolic velocity and WSS from 4D flow MRI and patient-specific CFD in 240 carotid arteries of 120 patients, with CFD geometries and boundary conditions derived from MRI. Velocity and circumferential WSS were compared at three standardized cross-sections, and plaque-surface WSS in 63 of 149 stenosed arteries with a reliably segmented plaque. Agreement was assessed with Bland-Altman analysis, Spearman correlation with stenosis degree, and exploratory multivariable regression of the plaque-surface discrepancy on hemodynamic and geometric variables. MRI reproduced the broad flow features but underestimated peak velocity, increasingly toward the distal internal carotid artery. WSS disagreement was location dependent: mean circumferential WSS showed little average bias in the common carotid artery, whereas MRI missed the high WSS at the bifurcation apex and underestimated plaque-surface mean and maximum WSS by $40.9 \pm 28.8\%$ and $44.5 \pm 26.8\%$; the difference in Pa increased with stenosis degree ($ρ= 0.47$ and $0.50$). In exploratory regression, the CFD-derived pressure drop across the plaque was the only significant correlate of the mean WSS discrepancy, whereas stenosis degree and geometric variables were associated with the maximum WSS discrepancy. Under the present protocol, MRI-derived plaque-surface WSS showed magnitude- and location-dependent disagreement with CFD, greater in more severely stenosed arteries and, in exploratory analyses, associated with factors beyond stenosis degree.

physics.flu-dyn

Attention-guided super-resolution of 4D flow MRI in carotid arteries

Four-dimensional (4D) flow magnetic resonance imaging (MRI) is a powerful non-invasive technique for visualizing and quantifying complex blood flow patterns in vivo. Despite its clinical promise, broader adoption is limited by low spatial resolution and sensitivity to noise, which restrict accurate assessment of critical hemodynamic biomarkers such as wall shear stress, pressure gradients, and turbulent kinetic energy. To overcome these challenges, we propose a deep learning-based super-resolution framework that integrates multi-scale feature extraction and attention mechanisms to enhance the quality of 4D flow MRI data. The model was trained on a dataset of 120 patients with 240 stenosed carotid arteries. High-resolution ground truth data were generated using patient-specific computational fluid dynamics (CFD) simulations based on segmented vascular geometries and physiologically realistic boundary conditions, and the resulting velocity fields served as targets for supervised learning. The proposed architecture uses convolutional block attention modules (CBAM) to guide the network toward clinically relevant spatial features and to suppress noise in low-resolution inputs. Quantitative results show that the attention-guided model substantially reduces the root mean square error (RMSE) compared with a baseline model without attention, and qualitative velocity contour analysis confirms improved reconstruction of intricate flow patterns. These findings highlight the capacity of the model to restore high-fidelity flow fields under noisy conditions and support the use of deep learning to extend the clinical utility of 4D flow MRI for non-invasive hemodynamic assessment.

physics.med-ph

Fluid dynamics informed CCTA-derived geometric parameters in right coronary artery anomalies predict abnormal invasive Adenosine FFR and Dobutamine FFR

Background: Right anomalous aortic origin of coronary arteries (R-AAOCA) involves fixed compression, assessable with adenosine-derived fractional flow reserve (FFRAdnosine), and additional stress-induced dynamic compression captured by dobutamine-derived FFR (FFRDobutamine). We hypothesized that coronary CT angiography (CCTA)-derived fluid dynamics-informed parameters outperform conventional metrics in predicting both FFR types. Methods: We retrospectively analyzed CCTA data from R-AAOCA patients who underwent invasive FFRAdnosine and FFRDobutamine assessment. Parameters were categorized as: (1) conventional metrics (cross-sectional area, perimeter, minor/major axis, intramural lumen area [ILA], effective diameter, area and diameter stenosis ratios) and (2) fluid dynamics-informed metrics (hydraulic diameter, elliptic ratio, circularity, hydraulic diameter stenosis ratio, resistance index [RI], ostial angulation penalty [OAP], and comprehensive stenosis score [CSS]). Hemodynamic relevance was defined as FFR$\leq$0.80. Results: 81 patients were included. FFRAdnosine$\leq$0.80 occurred in 5 (6.2%) and FFRDobutamine$\leq$0.80 in 16 (19.8%) patients. For FFRAdnosine, top discriminators were RI (AUC=0.97), OAP (AUC=0.97), ostial area (AUC=0.96), and CSS (AUC=0.95). For FFRDobutamine, ostial minor diameter led (AUC=0.85), followed by RI (AUC=0.83) and ILA minor diameter (AUC=0.81). RI explained 45% and 43% of FFRAdnosine and FFRDobutamine variance, respectively. At optimal thresholds, RI achieved 100% sensitivity and 95% specificity for FFRAdnosine; ostial minor diameter achieved 100% sensitivity and 57% specificity for FFRDobutamine. Conclusions: In R-AAOCA, CCTA-derived fluid dynamics-informed metrics provide excellent and superior performance compared with conventional geometric parameters in predicting hemodynamic relevance of fixed compression.

physics.med-ph

Transverse flow under oscillating stimulation in helical square ducts with cochlea-like geometrical curvature and torsion

The cochlea is our fluid-filled organ of hearing with a unique spiral shape. The physiological role of this shape remains unclear. Previous research has paid only little attention to the occurrence of transverse flow in the cochlea, in particular in relation to the cochlea's shape. To better understand its influence on fluid dynamics, this study aims to characterize transverse flow due to harmonically oscillating axial flow in square ducts with curvature and torsion, similar to the shape of human cochleae. Four geometries were investigated to study curvature and torsion effects on axial and transverse fluid flow components. Twelve frequencies from 0.125 Hz to 256 Hz were studied, covering infrasound and low-frequency hearing, with mean inlet velocity amplitudes representing levels expected for normal conversations or louder situations. Our simulations show that torsion contributes significantly to transverse flow in unsteady conditions, and that its contribution increases with increasing oscillation frequencies. Curvature has a small effect on transverse flow, which decreases rapidly for increasing frequencies. Strikingly, the combined effect of curvature and torsion on transverse flow is greater than expected from a simple superposition of the two effects, especially when the relative contribution of curvature alone becomes negligible. These findings could be relevant to understand physiological processes in the cochlea, including metabolite transport and wall shear stresses. Further studies are needed to investigate possible implications on cochlear mechanics.

physics.flu-dyn

An immersed boundary method for fluid-structure interaction based on overlapping domain decomposition

We present a novel framework inspired by the Immersed Boundary Method for predicting the fluid-structure interaction of complex structures immersed in flows with moderate to high Reynolds numbers. The main novelties of the proposed fluid-structure interaction framework are 1) the use of elastodynamics equations for the structure, 2) the use of a high-order Navier-Stokes solver for the flow, and 3) the variational transfer (L2-projection) for coupling the solid and fluid subproblems. The dynamic behavior of a deformable structure is simulated in a finite element framework by adopting a fully implicit scheme for its temporal integration. It allows for mechanical constitutive laws including nonhomogeneous and fiber-reinforced materials. The Navier-Stokes equations for the incompressible flow are discretized with high-order finite differences which allow for the direct numerical simulation of laminar, transitional and turbulent flows. The structure and the flow solvers are coupled by using an L2-projection method for the transfer of velocities and forces between the fluid grid and the solid mesh. This strategy allows for the numerical solution of coupled large scale problems based on nonconforming structured and unstructured grids. The framework is validated with the Turek-Hron benchmark and a newly proposed benchmark modelling the flow-induced oscillation of an inert plate. A three-dimensional simulation of an elastic beam in transitional flow is provided to show the solver's capability of coping with anisotropic elastic structures immersed in complex fluid flow.

physics.comp-ph