Introduction to Quantum Ophthalmology

Quantum technologies are rapidly advancing across multiple research domains, with a growing impact on biomedical imaging and sensing. We examine their emerging role in ophthalmology through four complementary directions: photon-limited retinal imaging, correlation based imaging, nanoscale optical probes, and quantum-limited visual perception. Advances in optical coherence tomography and single-photon detection enable imaging under strict photon budget constraints, reducing phototoxicity while preserving image quality. Correlation-based approaches, including ghost imaging, offer alternative strategies for image formation in low-light and scattering environments, although practical implementation remains limited by detection efficiency and acquisition time. In parallel, nanoscale optical platforms such as quantum dots provide tunable and photostable probes for enhanced contrast and targeted delivery, with ongoing challenges related to biocompatibility and clinical translation. Finally, experiments at the single-photon level and with structured light fields demonstrate how the visual system itself operates near physical detection limits and can be probed using controlled optical states. While many of these approaches remain at an early stage, they collectively illustrate how quantum and quantum-inspired methods may augment current ophthalmic imaging and diagnostic technologies while providing new tools for studying visual function under well-defined physical constraints.

physics.med-ph

Test-retest Reliability of Psychophysical Tasks Using Structured Light-Induced Entoptic Phenomena

Structured light (SL)-induced polarization perception presents a promising method for the early detection of macular diseases such as age-related macular degeneration. We investigated the test-retest reliability of a psychophysical task using SL-based stimuli to induce entoptic patterns in individuals with healthy vision. Twenty-eight participants underwent thorough eye examinations to confirm they had healthy eyes and good vision (logMAR BCVA ~0.00). Of these, 25 participants (n=50 eyes) aged 21 to 75 completed two identical tasks separated by 1 to 14 days. Using SL-based stimuli that produced a rotating entoptic pattern containing 22 azimuthal brushes, we measured the retinal eccentricity threshold $R_T$ at which participants could reliably identify the direction of rotation by varying the size of a central obstruction. This threshold reflects the visual angle of the pattern for each participant. We calculated the reliability coefficient (intraclass correlation coefficient, ICC) using a two-way mixed-effects model and conducted a Bland-Altman analysis to assess test-retest reliability. The ICC was 0.83 [95% CI: 0.62 - 0.93] for right eyes (RE) and 0.93 [95% CI: 0.84 - 0.97] for left eyes (LE), indicating good reliability. The Bland-Altman analysis showed a mean difference of -0.32{\deg} (SD: 1.51) and -0.12{\deg} (SD: 1.03) for RE and LE respectively between the first and second sessions, with limits of agreement ranging from -3.28{\deg} to 2.64{\deg} and -2.14{\deg} to 1.89{\deg} for RE and LE respectively, confirming strong agreement and no significant bias. These results demonstrate that SL-based psychophysical tasks are a reliable method for assessing polarization perception, potentially improving screening for diseases affecting macular health.

physics.med-ph

Eye dominance and testing order effects in the circularly-oriented macular pigment optical density measurements that rely on the perception of structured light-based stimuli

Psychophysical discrimination of structured light (SL) stimuli may be useful in screening for various macular disorders, including degenerative macular diseases. The circularly-oriented macular pigment optical density (coMPOD), calculated from the discrimination performance of SL-induced entoptic phenomena, may reveal a novel functional biomarker of macular health. In this study, we investigated the potential influence of eye dominance and testing order effects on SL-based stimulus perception, factors that potentially influence the sensitivity of screening tests based on SL technology. A total of 28 participants (aged 18-38 years) were selected for the study after undergoing a comprehensive eye examination. A psychophysical task was performed where various SL-based entoptic images with multiple azimuthal fringes rotating with a specific temporal frequency were projected onto the participants' retinas. By occluding the central areas of entoptic images, we measured the retinal eccentricity ($R$) of the perceivable area of the stimuli. The slope of the coMPOD profile ($a$-value) was calculated for each participant using a spatiotemporal sensitivity model that takes into account the perceptual threshold measurements of structured light stimuli with varying spatial densities and temporal frequencies. The Pearson correlation coefficient between eye dominance and testing order effects was $r=0.8$ ($p<0.01$). The Bland-Altman plots for both factors indicated zero bias. The results indicate repeatable measurements for both eyes, implying minimal impact from eye dominance and testing order on SL-based stimulus perception. The results provide a foundation for future studies exploring the clinical utility of SL tools in eye health.

q-bio.NC

Demonstration of a white beam far-field neutron interferometer for spatially resolved small angle neutron scattering

We provide the first demonstration that a neutron far-field interferometer can be employed to measure the microstructure of a sample. The interferometer is based on the moir\'e pattern of two phase modulating gratings which was previously realized in hard x-ray and visible light experiments. The autocorrelation length of this interferometer, and hence the microstructure length scale that is probed, is proportional to the grating spacing and the neutron wavelength, and can be varied over several orders of magnitude for one pair of gratings. We compare our measurements of the change in visibility from monodisperse samples with calculations which show reasonable agreement. The potential advantages of a far-field neutron interferometer include high fringe visibility in a polychromatic beam (over 30 %), no requirement for an absorbing grating to resolve the interference fringes, and the ability to measure the microstructure in the length scale range of 100 nm to 10 \mum by varying either the grating spacing or neutron wavelength with a broad wavelength range and single set of gratings.

physics.ins-det