arXiv ScienceSearch

arXiv subjects

Dina Hannebauer

Publications and source records attributed to Dina Hannebauer.

3 recordsLinked to original sources

Screening bolt loosening in a four-bolt plate with global FRF correlation and local FRAC maps from full-field laser Doppler vibrometry

Full-field laser Doppler vibrometry (LDV) can reveal how bolt torque loss redistributes a frequency response function (FRF) over an entire structure rather than only at a few sensor positions. This work presents a screening procedure for a four-bolt aluminum plate using pointwise amplitude and phase exports of scanned H1 FRFs. Candidate resonances were selected from the all-tight spatial RMS spectrum and tracked in four single-bolt 0 Nm cases. Seven baseline responses remained trackable within prescribed group-specific search windows and were retained as experimental resonance groups RG1-RG7; a dimensionless plate-frequency coefficient was reported alongside each measured frequency. Global changes were quantified using amplitude-only and complex, phase-retaining modal-assurance dissimilarities, and local changes were evaluated using matched-window FRAC-deficit maps and a normalized hotspot-area fraction. The retained groups separate into low-, intermediate-, and high-distortion responses, while the local maps distinguish compact joint-centered changes from distributed FRF redistribution. The workflow therefore links global FRF distortion with spatially resolved interpretation without relying on a trained classifier or specimen-specific node labels.

physics.optics

Full-field laser-Doppler-vibrometry FRF dataset for a four-bolt aluminum plate under bolt-torque variation

The dataset described in this article was constructed using the results of laser Doppler vibrometry experiments conducted on an aluminum plate having four bolts. The database captures the variation in the vibration characteristics of the plate as a function of changes in tightening torque on the bolts. In total, there were 18 different states for the tightening torque, ranging from a situation where all bolts are tightened to all bolts being loose. Other possible combinations include states with varying torque applied to just one bolt, and those involving multiple loose bolts. Data consist of 1,836 files exported from Polytec PSV-500, categorized as amplitude and phase data, for frequency ranges spanning 1 Hz to 51,200 Hz at intervals of 1 Hz. The identified zones were analyzed at 51 scan points for all states of torque. Supporting documents included specifications of the test plate, scan point and torque state information, selected resonance peaks tables, measured frequencies for seven resonance groups, correlation values for all FRF, visualizations, and code scripts.

eess.SP

Frequency-Modulated and Single-Tone Excitation to Reveal Vibro-Acoustic Nonlinearities in Loosened Bolted Joints

Preload loss in bolted joints results in alterations of the stiffness, damping, and nonlinearity of the structure, but existing monitoring techniques for rail-vehicle systems are often not capable of combining controlled shaker tests and sensing of nonlinear features. This paper proposes a method for detecting bolt loosening using a vibro-acoustic technique, where the structure is subjected to controlled shaker tests to sense the nonlinear features. A triaxial accelerometer was attached to the demonstrator, a microphone was placed in close proximity, and one of the bolts was tested under 0%, 20%, 40%, and 80% preload conditions. Single-tone and frequency-modulated (FM) signals close to the main natural frequency of 130 Hz, which was identified using sine sweep and narrow-band excitation, were applied to the demonstrator. When the structure was subjected to 130 Hz single-tone excitation, the loose state of the bolt exhibited several additional high-frequency spectral peaks. FM excitation between 125 and 135 Hz further distinguished between the states. Harmonic band power ratios, normalized to the carrier, distinguished between the loose state and the 80% preload state, where the difference between the loose and 80% preload states was 17.5 dB for l = 2 and 36.5 dB for l = 6.

eess.AS