arXiv ScienceSearch

arXiv subjects

Davide Ziviani

Publications and source records attributed to Davide Ziviani.

8 recordsLinked to original sources

Bayesian thermal digital twin for a space habitat subjected to an impact event

Space habitats may experience disruptive events, such as micro-meteorite impacts, that can induce structural damage and thermal anomalies in the interior environment, requiring resilient Environmental Control and Life Support Systems (ECLSS). Digital twins offer a promising paradigm for supporting resilience, onboard decision making, and uncertainty-aware autonomy. However, limited work has developed digital twins for the thermal aspects of ECLSS. This work develops a Bayesian thermal digital twin for a habitat cyber-physical testbed experiencing impact-induced thermal anomalies. We construct a coupled thermal resistance-capacitance network model representing the physical and cyber thermal subsystems and embed physics-based activation functions to automate model selection, enable adaptation, and facilitate health-state estimation. Offline Bayesian calibration is performed for the physical subsystem using experimental temperature data. For the cyber subsystem, reduction in structural protective layer thickness is identified as the impact-sensitive parameter. After fixing the physical parameters and insensitive parameters, Bayesian inference is performed continuously to estimate impact-relevant cyber parameters, enabling detection of impact location, timing, and severity. Synthetic studies examine hyperparameter selection, observability, and noise effects, and the final framework is validated using experimental testbed data. Results show that the proposed digital twin can detect impact-induced thermal anomalies, infer impact-relevant parameters with quantified uncertainty, generate informative temperature forecasts, and support time-to-critical estimation for autonomous habitat operation.

eess.SY

Laboratory and field testing of a residential heat pump retrofit for a DC solar nanogrid

Residential buildings are increasingly integrating large devices that run natively on direct current (DC), such as solar photovoltaics, electric vehicles, stationary batteries, and DC motors that drive heat pumps and other major appliances. Today, these natively-DC devices typically connect within buildings through alternating current (AC) distribution systems, entailing significant energy losses due to conversions between AC and DC. This paper investigates the alternative of connecting DC devices through DC distribution. Specifically, this paper shows through laboratory and field experiments that an off-the-shelf residential heat pump designed for conventional AC systems can be powered directly on DC with few hardware modifications and little change in performance. Supporting simulations of a DC nanogrid including {historical heat pump and rest-of-house load measurements,} a solar photovoltaic array, and a stationary battery suggest that connecting these devices through DC distribution could decrease annual electricity bills by 12.5% with an after-market AC-to-DC heat pump retrofit and by 16.7% with a heat pump designed to run on DC. The associated savings in gross nanogrid energy are 8% and 9.2%, respectively.

eess.SY

Model predictive control lowers barriers to adoption of heat-pump water heaters: A field study

Electric heat-pump water heaters (HPWHs) could reduce the energy costs, emissions, and power grid impacts associated with water heating, the second-largest energy use in United States housing. However, most HPWHs today require 240 V circuits to power the backup resistance heating elements they use to maintain comfort during large water draws. Installing a 240 V circuit can increase the up-front cost of a HPWH by half or more. This paper develops and field-tests the first control system that enables a 120 V HPWH to efficiently maintain comfort without resistance heating elements. The novel model predictive control (MPC) system enables pre-heating in anticipation of large water draws, which it forecasts using an ensemble of machine learning predictors. By shifting electrical load over time, MPC also reduces energy costs on average by 23% and 28% under time-of-use pricing and hourly pricing, respectively, relative to a 240 V HPWH with standard controls. Compared to the increasingly common practice in 120 V HPWHs of storing water at a constant, high temperature (60 °C) to ensure comfort, MPC saves 37% energy on average. In addition to demonstrating MPC's benefits in a real, occupied house, this paper discusses implementation challenges and costs. A simple payback analysis suggests that a 120 V HPWH, operated by the MPC system developed here, would be economically attractive in most installation scenarios.

eess.SY

Asymptotic Behavior of a Buoyant Jet Regime inside a Carbon-dioxide Ejector

Ejectors are used in various engineering systems, including steam and vapor compression cycles. Optimizing the performance of ejectors requires understanding and analysis of multiphase and turbulent flow structures associated with their internal flow fields. This approach yields higher fidelity but at a high computational cost. Lower-fidelity one-dimensional (1D) models offer lower computational costs; however, 1D models are often empirical and provide limited understanding of the internal flow fields, overlooking possibilities of optimization. Ejector flows can be categorized into four regimes: Regime 1 (R1), which is compressibility dominated; Regime 2 (R2), which is interface instability driven; Regime 3 (R3), which is buoyancy dominated; and Regime 4 (R4), which is a wall-bounded turbulent jet expansion. Among these, the buoyancy-dominated regime is the most complex and least understood. This work discusses an approach to develop a reduced-order model utilizing a self-similarity framework to capture the internal flow field of the jet within the buoyancy-dominated regime under quasi-steady, compressible, and isothermal flow conditions, where density variations arise only from mixing. The density variation is captured through the Favre-averaging approach. The model captures the expansion of a central jet influenced by momentum diffusivity and a constant streamwise pressure gradient. Interaction of the central jet with the cylindrical wall induces a counterflow annular wall jet due to the combined effects of negative radial density gradients and shear stress imposed by the wall. Initially, the discussion focuses on flow topology inside the ejector, followed by the self-similarity methodology and implementation of asymptotic analysis. Finally, the resemblance...

physics.flu-dyn

Protecting residential electrical panels and service through model predictive control: A field study

Residential electrification - replacing fossil-fueled appliances and vehicles with electric machines - can significantly reduce greenhouse gas emissions and air pollution. However, installing electric appliances or vehicle charging in a residential building can sharply increase its current draws. In older housing, high current draws can jeopardize electrical infrastructure, such as circuit breaker panels or electrical service (the wires that connect a building to the distribution grid). Upgrading electrical infrastructure can entail long delays and high costs, so poses a significant barrier to electrification. This paper develops and field-tests a control system that avoids the need for electrical upgrades by keeping an electrified home's total current draw within the safe limits of its panel and service. In the proposed control architecture, a high-level controller plans device set-points over a rolling prediction horizon. A low-level controller monitors real-time conditions and ramps down devices if necessary. The control system was tested in an occupied, electrified single-family house with code-minimum insulation, an air-to-air heat pump and backup resistance heat, a resistance water heater, and a plug-in hybrid electric vehicle with Level I charging. The field tests spanned 31 winter days with outdoor temperatures as low as -20 C. The control system maintained the whole-home current within the safe limits of electrical panels and service rated at 100 A, a common rating for older houses in North America, by adjusting only the temperature set-points of the heat pump and water heater. Simulations suggest that the same 100 A limit could accommodate a second electric vehicle with Level II charging. The proposed control system could allow older homes to safely electrify without upgrading electrical panels or service, saving a typical household on the order of $2,000 to $10,000.

eess.SY

Humidity-Aware Model Predictive Control for Residential Air Conditioning: A Field Study

Model predictive control of residential air conditioning could reduce energy costs and greenhouse gas emissions while maintaining or improving occupants' thermal comfort. However, most approaches to predictive air conditioning control either do not model indoor humidity or treat it as constant. This simplification stems from challenges with modeling indoor humidity dynamics, particularly the high-order, nonlinear equations that govern heat and mass transfer between the air conditioner's evaporator coil and the indoor air. This paper develops a machine-learning approach to modeling indoor humidity dynamics that is suitable for real-world deployment at scale. This study then investigates the value of humidity modeling in four field tests of predictive control in an occupied house. The four field tests evaluate two different building models: One with constant humidity and one with time-varying humidity. Each modeling approach is tested in two different predictive controllers: One that focuses on reducing energy costs and one that focuses on constraining electric power below a utility-specified threshold. The two models lead to similar performance for reducing energy costs. Combining the results of this study and a prior heating study of the same house, the estimated year-round energy cost savings were $340-497 or 22-31% (95% confidence intervals); these savings were consistent across both humidity models. However, in the demand response tests, the simplifying assumption of constant humidity led to far more frequent and severe violations of the power constraint. These results suggest that accurate building models are important for nonlinear objectives, such as reducing or constraining peak demand, while for linear objectives such as reducing energy costs or emissions, model accuracy is less important.

eess.SY

Field demonstration of predictive heating control for an all-electric house in a cold climate

Efficient electric heat pumps that replace fossil-fueled heating systems could significantly reduce greenhouse gas emissions. However, electric heat pumps can sharply increase electricity demand, causing high utility bills and stressing the power grid. Residential neighborhoods could see particularly high electricity demand during cold weather, when heat demand rises and heat pump efficiencies fall. This paper presents the development and field demonstration of a predictive control system for an air-to-air heat pump with backup electric resistance heat. The control system adjusts indoor temperature set-points based on weather forecasts, occupancy conditions, and data-driven models of the building and heating equipment. Field tests from January to March of 2023 in an occupied, all-electric, 208 m^2 detached single-family house in Indiana, USA, included outdoor temperatures as low as -15 C. On average over these tests, the control system reduced daily heating energy use by 19% (95% confidence interval: 13--24%), energy used for backup heat by 38%, and the frequency of using the highest stage (19 kW) of backup heat by 83%. Concurrent surveys of residents showed that the control system maintained satisfactory thermal comfort. The control system could reduce the house's total annual heating costs by about $300 (95% confidence interval: 23--34%). These real-world results could strengthen the case for deploying predictive home heating control, bringing the technology one step closer to reducing emissions, utility bills, and power grid impacts at scale.

eess.SY

Dynamic Modeling and Control of a Two-Reactor Metal Hydride Energy Storage System

Metal hydrides have been studied for use in energy storage, hydrogen storage, and air-conditioning (A/C) systems. A common architecture for A/C and energy storage systems is two metal hydride reactors connected to each other so that hydrogen can flow between them, allowing for cyclic use of the hydrogen. This paper presents a nonlinear dynamic model and multivariate control strategy of such a system. Each reactor is modelled as a shell-and-tube heat exchanger connected to a circulating fluid, and a compressor drives hydrogen flow between the reactors. We further develop a linear state-space version of this model integrated with a model predictive controller to determine the fluid mass flow rates and compressor pressure difference required to achieve desired heat transfer rates between the metal hydride and the fluid. A series of case studies demonstrates that this controller can track desired heat transfer rates in each reactor, even in the presence of time-varying circulating fluid inlet temperatures, thereby enabling the use of a two-reactor system for energy storage or integration with a heat pump.

eess.SY