Patient-specific Modeling of the Tricuspid Valve from 3D Transesophageal Echocardiography

Purpose: Image-based patient-specific simulations of the tricuspid valve (TV) could support repair planning. However, clinical images incompletely resolve the chordal anatomy and cannot directly determine tissue properties, which hinders the development of such models. We developed and evaluated a framework that simulates the TV from clinical images and addresses these limitations using measurements on explanted human valves. Methods: We reconstructed ten functionally competent human TVs from 3D transesophageal echocardiography. Following manual segmentation, we automatically built finite element models with synthetic chordae and with leaflet thickness, chordal insertion density, and tissue properties informed by ex vivo human measurements. Next, we used shape matching and force-based chordal-length adjustment to simulate valve closure. We also assessed inter-observer segmentation variability and sensitivity to chordal insertion density, leaflet stiffness, leaflet thickness, and chordal size and material properties. Results: Per-valve median geometric errors were 0.61-1.13 mm relative to the morphed references and 0.55-0.95 mm relative to the image-derived surfaces. Coaptation covered 20-42% of the leaflet area, and median leaflet stresses ranged from 7.6 to 16.9 kPa. Inter-observer variability in segmentation most strongly affected coaptation area. Of the population-based inputs, insertion density and leaflet stiffness most affected geometric error. Thickness primarily affected stress, whereas chordal size and material properties had limited effects. Conclusion: Clinical echocardiography, supplemented with ex vivo human tissue data, enabled patient-specific simulation of ten human TVs. This framework provides a foundation for investigating valve mechanics and developing repair-planning tools, while sensitivity analyses identify priorities for model refinement and uncertainty assessment.

cs.CE↗

MitraClip Device Automated Localization in 3D Transesophageal Echocardiography via Deep Learning

The MitraClip is the most widely percutaneous treatment for mitral regurgitation, typically performed under the real-time guidance of 3D transesophagel echocardiography (TEE). However, artifacts and low image contrast in echocardiography hinder accurate clip visualization. This study presents an automated pipeline for clip detection from 3D TEE images. An Attention UNet was employed to segment the device, while a DenseNet classifier predicted its configuration among ten possible states, ranging from fully closed to fully open. Based on the predicted configuration, a template model derived from computer-aided design (CAD) was automatically registered to refine the segmentation and enable quantitative characterization of the device. The pipeline was trained and validated on 196 3D TEE images acquired using a heart simulator, with ground-truth annotations refined through CAD-based templates. The Attention UNet achieved an average surface distance of 0.76 mm and 95% Hausdorff distance of 2.44 mm for segmentation, while the DenseNet achieved an average weighted F1-score of 0.75 for classification. Post-refinement, segmentation accuracy improved, with average surface distance and 95% Hausdorff distance reduced to 0.75 mm and 2.05 mm, respectively. This pipeline enhanced clip visualization, providing fast and accurate detection with quantitative feedback, potentially improving procedural efficiency and reducing adverse outcomes.

q-bio.QM↗