arXiv ScienceSearch

arXiv subjects

David Fink

Publications and source records attributed to David Fink.

9 recordsLinked to original sources

Spectroscopic performance of the electrical functional models for the eXTP SFA-T detectors

The Spectroscopy Focusing Array (SFA) is one of the three instruments on the eXTP satellite. It consists of six telescopes plus focal plane cameras, where five are equipped with a Silicon Drift Detector (SDD) array. These five SFA-T (T stands for timing) instruments are used for observations with high time resolution (better than 10 microseconds), high throughput (dead time less than 5 % when observing a 1 Crab source), and good energy resolution (better than 180 eV at 6 keV). This paper presents the spectroscopic performance of the Electrical Functional Modules (EFM) for SFA-T that are assembled and tested at the Max Planck Institute for Extraterrestrial Physics (MPE). A focus lies on the energy resolution at the planned sensor operating temperature of -45 {\deg}C. Additionally, the use of a baffle that covers the pixel edges is studied.

astro-ph.IM

Direct comparison of SiPMs and PMTs in operation with a bright background and prospects of using SPADs as truly digital sensors

The use of silicon photomultipliers (SiPMs) alongside conventional photomultiplier tubes (PMTs) is a remarkable technological development in modern ground-based very high energy gamma-ray astronomy. SiPMs exhibit comparable or even higher photon detection efficiencies (PDEs) than PMTs. The sensitivity of a PMT matches well the spectral shape of Cherenkov radiation from extended air showers. In contrast to a PMT, the sensitivity of a SiPM is shifted toward longer wavelengths, where the intensity of light of night sky (LoNS), considered as unwanted noise, increases significantly. It is obvious that a SiPM with a higher PDE will indeed measure more Cherenkov light than a PMT, but it will also detect significantly higher LoNS noise; the question is which factor will predominate in the signal-to-noise-ratio (SNR). To compare the performance of a PMT with that of a SiPM, we built SiPM-based modules and installed these and operated in parallel in the imaging camera of the 17 m diameter MAGIC telescope. Our long-term studies show that SiPM, despite their higher PDE, can deliver only a comparable to PMT performance. As already the name SiPM suggests, we use these semiconductor sensors analogously to classical PMTs: We amplify their small signals, digitize, and calibrate the converted amplitudes. Although SiPM is essentially a digital sensor, its common-anode design does not allow one to directly profit from it. Numerous arrays of single-photon avalanche diodes (SPADs) are being developed in various laboratories worldwide. Unlike SiPM, SPAD arrays digitize the incident photons from the outset and count their number. We will dwell on the potential further developments of SPADs.

astro-ph.IM

Characterizing the aerosol atmosphere above the Observatorio del Roque de los Muchachos by analyzing seven years of data taken with an GaAsP HPD-readout, absolutely calibrated elastic LIDAR

We present a new elastic LIDAR concept, based on a bi-axially mounted Nd:YAG laser and a telescope with HPD readout, combined with fast FADC signal digitization and offline pulse analysis. The LIDAR return signals have been extensively quality checked and absolutely calibrated. We analyze seven years of quasi-continuous LIDAR data taken during those nights when the MAGIC telescopes were operating. Characterization of the nocturnal ground layer yields zenith and azimuth angle dependent aerosol extinction scale heights for clear nights. We derive aerosol transmission statistics for light emitted from various altitudes throughout the year and separated by seasons. We find further seasonal dependencies of cloud base and top altitudes, but none for the LIDAR ratios of clouds. Finally, the night sky background light is characterized using the LIDAR photon backgrounds. abstract.txt

astro-ph.IM

Characterization measurements of the TRISTAN multi-pixel silicon drift detector

Sterile neutrinos are a minimal extension of the Standard Model of Particle Physics. A laboratory-based approach to search for this particle is via tritium beta-decay, where a sterile neutrino would cause a kink-like spectral distortion. The Karlsruhe Tritium Neutrino (KATRIN) experiment extended by a multi-pixel Silicon Drift Detector system has the potential to reach an unprecedented sensitivity to the keV-scale sterile neutrino in a lab-based experiment. The new detector system combines good spectroscopic performance with a high rate capability. In this work, we report about the characterization of charge-sharing between pixels and the commissioning of a 47-pixel prototype detector in a MAC-E filter.

physics.ins-det

Hunting keV sterile neutrinos with KATRIN: building the first TRISTAN module

The KATRIN (Karlsruhe Tritium Neutrino) experiment investigates the energetic endpoint of the tritium beta-decay spectrum to determine the effective mass of the electron anti-neutrino. The collaboration has reported a first mass measurement result at this TAUP-2019 conference. The TRISTAN project aims at detecting a keV-sterile neutrino signature by measuring the entire tritium beta-decay spectrum with an upgraded KATRIN system. One of the greatest challenges is to handle the high signal rates generated by the strong activity of the KATRIN tritium source while maintaining a good energy resolution. Therefore, a novel multi-pixel silicon drift detector and read-out system are being designed to handle rates of about 100 Mcps with an energy resolution better than 300 eV (FWHM). This report presents succinctly the KATRIN experiment, the TRISTAN project, then the results of the first 7-pixels prototype measurement campaign and finally describes the construction of the first TRISTAN module composed of 166 SDD-pixels as well as its implementation in KATRIN experiment.

physics.ins-det

A novel detector system for KATRIN to search for keV-scale sterile neutrinos

Sterile neutrinos are a minimal extension of the Standard Model of Particle Physics. If their mass is in the kilo-electron-volt regime, they are viable dark matter candidates. One way to search for sterile neutrinos in a laboratory-based experiment is via tritium-beta decay, where the new neutrino mass eigenstate would manifest itself as a kink-like distortion of the $\beta$-decay spectrum. The objective of the TRISTAN project is to extend the KATRIN setup with a new multi-pixel silicon drift detector system to search for a keV-scale sterile neutrino signal. In this paper we describe the requirements of such a new detector, and present first characterization measurement results obtained with a 7-pixel prototype system.

physics.ins-det

Optimisation of the Read-out Electronics of Muon Drift-Tube Chambers for Very High Background Rates at HL-LHC and Future Colliders

In the ATLAS Muon Spectrometer, Monitored Drift Tube (MDT) chambers and sMDT chambers with half of the tube diameter of the MDTs are used for precision muon track reconstruction. The sMDT chambers are designed for operation at high counting rates due to neutron and gamma background irradiation expected for the HL-LHC and future hadron colliders. The existing MDT read-out electronics uses bipolar signal shaping which causes an undershoot of opposite polarity and same charge after a signal pulse. At high counting rates and short electronics dead time used for the sMDTs, signal pulses pile up on the undershoot of preceding background pulses leading to a reduction of the signal amplitude and a jitter in the drift time measurement and, therefore, to a degradation of drift tube efficiency and spatial resolution. In order to further increase the rate capability of sMDT tubes, baseline restoration can be used in the read-out electronics to suppress the pile-up effects. A discrete bipolar shaping circuit with baseline restoration has been developed and used for reading out sMDT tubes under irradiation with a 24 MBq 90Sr source. The measurements results show a substantial improvement of the performance of the sMDT tubes at high counting rates.

physics.ins-det

Silicon Photomultiplier Research and Development Studies for the Large Size Telescope of the Cherenkov Telescope Array

The Cherenkov Telescope Array (CTA) is the the next generation facility of imaging atmospheric Cherenkov telescopes; two sites will cover both hemispheres. CTA will reach unprecedented sensitivity, energy and angular resolution in very-high-energy gamma-ray astronomy. Each CTA array will include four Large Size Telescopes (LSTs), designed to cover the low-energy range of the CTA sensitivity ($\sim$20 GeV to 200 GeV). In the baseline LST design, the focal-plane camera will be instrumented with 265 photodetector clusters; each will include seven photomultiplier tubes (PMTs), with an entrance window of 1.5 inches in diameter. The PMT design is based on mature and reliable technology. Recently, silicon photomultipliers (SiPMs) are emerging as a competitor. Currently, SiPMs have advantages (e.g. lower operating voltage and tolerance to high illumination levels) and disadvantages (e.g. higher capacitance and cross talk rates), but this technology is still young and rapidly evolving. SiPM technology has a strong potential to become superior to the PMT one in terms of photon detection efficiency and price per square mm of detector area. While the advantage of SiPMs has been proven for high-density, small size cameras, it is yet to be demonstrated for large area cameras such as the one of the LST. We are working to develop a SiPM-based module for the LST camera, in view of a possible camera upgrade. We will describe the solutions we are exploring in order to balance a competitive performance with a minimal impact on the overall LST camera design.

astro-ph.IM

Towards SiPM camera for current and future generations of Cherenkov telescopes

So far the current ground-based Imaging Atmospheric Cherenkov Telescopes (IACTs) have energy thresholds in the best case in the range of ~30 to 50 GeV (H.E.S.S. II and MAGIC telescopes). Lowest energy gamma-ray showers produce low light intensity images and cannot be efficiently separated from dominating images from hadronic background. A cost effective way of improving the telescope performance at lower energies is to use novel photosensors with superior photon detection efficiency (PDE). Currently the best commercially available superbialkali photomultipliers (PMTs) have a PDE of about 30-33%, whereas the silicon photomultipliers (SiPMs, also known as MPPC, GAPD) from some manufacturers show a photon detection efficiency of about 40-45%. Using these devices can lower the energy threshold of the instrument and may improve the background rejection due to intrinsic properties of SiPMs such as a superb single photoelectron resolution. Compared to PMTs, SiPMs are more compact, fast in response, operate at low voltage, and are insensitive to magnetic fields. SiPMs can be operated at high background illumination, which would allow to operate the IACT also during partial moonlight, dusk and dawn, hence increasing the instrument duty cycle. We are testing the SiPMs for Cherenkov telescopes such as MAGIC and CTA. Here we present an overview of our setup and first measurements, which we perform in two independent laboratories, in Munich, Germany and in Barcelona, Spain.

astro-ph.IM