arXiv ScienceSearch

arXiv subjects

Dan Ruan

Publications and source records attributed to Dan Ruan.

At least 19 recordsLinked to original sources

The Right Prior for the Right Deformation: Rethinking Continuous Deformable Image Registration

Deformable image registration models implicitly encode deformation priors through their parametrization and optimization. In this work, we conduct a validation study on continuous registration methods to examine how these implicit priors affect performance across different registration tasks. Classic B-Spline transformations impose locality, smoothness, and scale through their control-point structure, whereas recent INR-based methods impose different priors through neural parameterization and optimization. We compare INR-Dense (IDIR), which directly models a dense displacement field using a SIREN-based INR; INR-BSCP (SINR), which predicts B-Spline control points with an INR; D-BSCP, which directly optimizes single-scale B-Spline control points; and MR-D-BSCP, which adds a multiresolution coarse-to-fine scheme. Experiments on inter-subject brain MR registration (OASIS) and intra-subject exhale-to-inhale lung CT registration (DIR-LAB 4DCT) reveal different behavior across deformation regimes. On OASIS, where deformations are moderate but locally complex, D-BSCP matches or slightly outperforms INR-BSCP, suggesting that the B-Spline parameterization accounts for much of INR-BSCP's effectiveness. On DIR-LAB 4DCT, where respiratory motion is larger and more coherent, single-scale B-Spline methods (D-BSCP and INR-BSCP) are less suitable, while INR-Dense and MR-D-BSCP are more effective. Across both tasks, MR-D-BSCP achieves the best performance among the tested continuous parameterizations. These findings highlight that registration accuracy depends strongly on matching the induced deformation prior to the target motion pattern, and support prior-deformation matching as a practical design principle for medical image registration. Our code will be available at https://github.com/HengjieLiu/RightPriorDIR.

cs.CV

Beyond the LUMIR challenge: The pathway to foundational registration models

Medical image challenges have played a transformative role in advancing the field, catalyzing innovation and establishing new performance benchmarks. Image registration, a foundational task in neuroimaging, has similarly advanced through the Learn2Reg initiative. Building on this, we introduce the Large-scale Unsupervised Brain MRI Image Registration (LUMIR) challenge, a next-generation benchmark for unsupervised brain MRI registration. Previous challenges relied upon anatomical label maps, however LUMIR provides 4,014 unlabeled T1-weighted MRIs for training, encouraging biologically plausible deformation modeling through self-supervision. Evaluation includes 590 in-domain test subjects and extensive zero-shot tasks across disease populations, imaging protocols, and species. Deep learning methods consistently achieved state-of-the-art performance and produced anatomically plausible, diffeomorphic deformation fields. They outperformed several leading optimization-based methods and remained robust to most domain shifts. These findings highlight the growing maturity of deep learning in neuroimaging registration and its potential to serve as a foundation model for general-purpose medical image registration.

eess.IV

Zero-shot Multi-Contrast Brain MRI Registration by Intensity Randomizing T1-weighted MRI (LUMIR25)

In this paper, we present our submission to the LUMIR25 task of Learn2Reg 2025, which ranked 1st overall on the test set. Extended from LUMIR24, this year's task focuses on zero-shot registration under domain shifts (e.g., high-field MRI, pathological brains, and various MRI contrasts), while the training data comprises only in-domain T1-weighted brain MRI. We start with a meticulous analysis of LUMIR24 winners to identify the main contributors to strong monomodal registration performance. We highlight the importance of registration-specific inductive biases, including multi-resolution pyramids, inverse and group consistency, topological preservation or diffeomorphism, and correlation-based correspondence establishment. To further generalize to diverse contrasts, we employ three simple but effective strategies: (i) a multimodal loss based on the modality-independent neighborhood descriptor (MIND), (ii) intensity randomization for unseen contrast augmentation, and (iii) lightweight instance-specific optimization (ISO) on feature encoders at inference time. On the validation set, the proposed approach substantially improves T1-T2 registration accuracy, demonstrating robust cross-contrast generalization without relying on explicit image synthesis. These results suggest a practical step toward a registration foundation model that can leverage a single training domain yet remain robust across domain shifts.

eess.IV

Learn2Reg 2024: New Benchmark Datasets Driving Progress on New Challenges

Medical image registration is critical for clinical applications, and fair benchmarking of different methods is essential for monitoring ongoing progress in the field. To date, the Learn2Reg 2020-2023 challenges have released several complementary datasets and established metrics for evaluations. Building on this foundation, the 2024 edition expands the challenge's scope to cover a wider range of registration scenarios, particularly in terms of modality diversity and task complexity, by introducing three new tasks, including large-scale multi-modal registration and unsupervised inter-subject brain registration, as well as the first microscopy-focused benchmark within Learn2Reg. The new datasets also inspired new method developments, including invertibility constraints, pyramid features, keypoints alignment and instance optimisation. Visit Learn2Reg at https://learn2reg.grand-challenge.org.

eess.IV

Benchmark of Segmentation Techniques for Pelvic Fracture in CT and X-ray: Summary of the PENGWIN 2024 Challenge

The segmentation of pelvic fracture fragments in CT and X-ray images is crucial for trauma diagnosis, surgical planning, and intraoperative guidance. However, accurately and efficiently delineating the bone fragments remains a significant challenge due to complex anatomy and imaging limitations. The PENGWIN challenge, organized as a MICCAI 2024 satellite event, aimed to advance automated fracture segmentation by benchmarking state-of-the-art algorithms on these complex tasks. A diverse dataset of 150 CT scans was collected from multiple clinical centers, and a large set of simulated X-ray images was generated using the DeepDRR method. Final submissions from 16 teams worldwide were evaluated under a rigorous multi-metric testing scheme. The top-performing CT algorithm achieved an average fragment-wise intersection over union (IoU) of 0.930, demonstrating satisfactory accuracy. However, in the X-ray task, the best algorithm achieved an IoU of 0.774, which is promising but not yet sufficient for intra-operative decision-making, reflecting the inherent challenges of fragment overlap in projection imaging. Beyond the quantitative evaluation, the challenge revealed methodological diversity in algorithm design. Variations in instance representation, such as primary-secondary classification versus boundary-core separation, led to differing segmentation strategies. Despite promising results, the challenge also exposed inherent uncertainties in fragment definition, particularly in cases of incomplete fractures. These findings suggest that interactive segmentation approaches, integrating human decision-making with task-relevant information, may be essential for improving model reliability and clinical applicability.

eess.IV

Physics-informed Deep Diffusion MRI Reconstruction with Synthetic Data: Break Training Data Bottleneck in Artificial Intelligence

Diffusion magnetic resonance imaging (MRI) is the only imaging modality for non-invasive movement detection of in vivo water molecules, with significant clinical and research applications. Diffusion weighted imaging (DWI) MRI acquired by multi-shot techniques can achieve higher resolution, better signal-to-noise ratio, and lower geometric distortion than single-shot, but suffers from inter-shot motion-induced artifacts. These artifacts cannot be removed prospectively, leading to the absence of artifact-free training labels. Thus, the potential of deep learning in multi-shot DWI reconstruction remains largely untapped. To break the training data bottleneck, here, we propose a Physics-Informed Deep DWI reconstruction method (PIDD) to synthesize high-quality paired training data by leveraging the physical diffusion model (magnitude synthesis) and inter-shot motion-induced phase model (motion phase synthesis). The network is trained only once with 100,000 synthetic samples, achieving encouraging results on multiple realistic in vivo data reconstructions. Advantages over conventional methods include: (a) Better motion artifact suppression and reconstruction stability; (b) Outstanding generalization to multi-scenario reconstructions, including multi-resolution, multi-b-value, multi-under-sampling, multi-vendor, and multi-center; (c) Excellent clinical adaptability to patients with verifications by seven experienced doctors (p<0.001). In conclusion, PIDD presents a novel deep learning framework by exploiting the power of MRI physics, providing a cost-effective and explainable way to break the data bottleneck in deep learning medical imaging.

eess.IV

A Telecentric Offset Reflective Imaging System (TORIS) for Terahertz Imaging and Spectroscopy

Terahertz (THz) imaging has emerged as a promising technology in medical diagnostics due to its non-ionizing radiation and high sensitivity to water content. However, conventional THz imaging systems face limitations such as slow mechanical scanning, restricted field of view, and poor telecentricity. To overcome these challenges, we introduce the Telecentric Offset Reflective Imaging System (TORIS), a novel dual-mirror scanning design optimized for high-speed, distortion-free imaging. The system employs a telecentric f-theta lens and is validated using ray tracing and physical optics simulations. It achieves uniform resolution across a 50 mm x 50 mm field of view without the need for mechanical translation stages. Broadband spectral imaging of a USAF resolution test target across WR-2.2 (325-500 GHz) and WR-1.5 (500-700 GHz) frequency bands demonstrates consistent beam focus and minimal distortion, with a maximum deviation of 2.7 degrees from normal incidence and a beam waist of 2.1 lambda at the field edge in the WR-1.5 band. The system's sensitivity to hydration dynamics is further validated through imaging of wet tissue paper, capturing temporal changes in water content. In vivo imaging of human skin after capsaicin patch application reveals localized hydration variations due to biochemical response and adhesive removal. These findings confirm the system's potential for real-time hydration sensing and dermatological evaluation. TORIS sets a new benchmark in THz imaging, with applications in clinical diagnostics, wound assessment, and material characterization.

physics.optics

Accelerated Patient-specific Non-Cartesian MRI Reconstruction using Implicit Neural Representations

The scanning time for a fully sampled MRI can be undesirably lengthy. Compressed sensing has been developed to minimize image artifacts in accelerated scans, but the required iterative reconstruction is computationally complex and difficult to generalize on new cases. Image-domain-based deep learning methods (e.g., convolutional neural networks) emerged as a faster alternative but face challenges in modeling continuous k-space, a problem amplified with non-Cartesian sampling commonly used in accelerated acquisition. In comparison, implicit neural representations can model continuous signals in the frequency domain and thus are compatible with arbitrary k-space sampling patterns. The current study develops a novel generative-adversarially trained implicit neural representations (k-GINR) for de novo undersampled non-Cartesian k-space reconstruction. k-GINR consists of two stages: 1) supervised training on an existing patient cohort; 2) self-supervised patient-specific optimization. In stage 1, the network is trained with the generative-adversarial network on diverse patients of the same anatomical region supervised by fully sampled acquisition. In stage 2, undersampled k-space data of individual patients is used to tailor the prior-embedded network for patient-specific optimization. The UCSF StarVIBE T1-weighted liver dataset was evaluated on the proposed framework. k-GINR is compared with an image-domain deep learning method, Deep Cascade CNN, and a compressed sensing method. k-GINR consistently outperformed the baselines with a larger performance advantage observed at very high accelerations (e.g., 20 times). k-GINR offers great value for direct non-Cartesian k-space reconstruction for new incoming patients across a wide range of accelerations liver anatomy.

eess.IV

TomoGRAF: A Robust and Generalizable Reconstruction Network for Single-View Computed Tomography

Computed tomography (CT) provides high spatial resolution visualization of 3D structures for scientific and clinical applications. Traditional analytical/iterative CT reconstruction algorithms require hundreds of angular data samplings, a condition that may not be met in practice due to physical and mechanical limitations. Sparse view CT reconstruction has been proposed using constrained optimization and machine learning methods with varying success, less so for ultra-sparse view CT reconstruction with one to two views. Neural radiance field (NeRF) is a powerful tool for reconstructing and rendering 3D natural scenes from sparse views, but its direct application to 3D medical image reconstruction has been minimally successful due to the differences between optical and X-ray photon transportation. Here, we develop a novel TomoGRAF framework incorporating the unique X-ray transportation physics to reconstruct high-quality 3D volumes using ultra-sparse projections without prior. TomoGRAF captures the CT imaging geometry, simulates the X-ray casting and tracing process, and penalizes the difference between simulated and ground truth CT sub-volume during training. We evaluated the performance of TomoGRAF on an unseen dataset of distinct imaging characteristics from the training data and demonstrated a vast leap in performance compared with state-of-the-art deep learning and NeRF methods. TomoGRAF provides the first generalizable solution for image-guided radiotherapy and interventional radiology applications, where only one or a few X-ray views are available, but 3D volumetric information is desired.

eess.IV

Simultaneous Deep Learning of Myocardium Segmentation and T2 Quantification for Acute Myocardial Infarction MRI

In cardiac Magnetic Resonance Imaging (MRI) analysis, simultaneous myocardial segmentation and T2 quantification are crucial for assessing myocardial pathologies. Existing methods often address these tasks separately, limiting their synergistic potential. To address this, we propose SQNet, a dual-task network integrating Transformer and Convolutional Neural Network (CNN) components. SQNet features a T2-refine fusion decoder for quantitative analysis, leveraging global features from the Transformer, and a segmentation decoder with multiple local region supervision for enhanced accuracy. A tight coupling module aligns and fuses CNN and Transformer branch features, enabling SQNet to focus on myocardium regions. Evaluation on healthy controls (HC) and acute myocardial infarction patients (AMI) demonstrates superior segmentation dice scores (89.3/89.2) compared to state-of-the-art methods (87.7/87.9). T2 quantification yields strong linear correlations (Pearson coefficients: 0.84/0.93) with label values for HC/AMI, indicating accurate mapping. Radiologist evaluations confirm SQNet's superior image quality scores (4.60/4.58 for segmentation, 4.32/4.42 for T2 quantification) over state-of-the-art methods (4.50/4.44 for segmentation, 3.59/4.37 for T2 quantification). SQNet thus offers accurate simultaneous segmentation and quantification, enhancing cardiac disease diagnosis, such as AMI.

eess.IV

A Two-Step Framework for Multi-Material Decomposition of Dual Energy Computed Tomography from Projection Domain

Dual-energy computed tomography (DECT) utilizes separate X-ray energy spectra to improve multi-material decomposition (MMD) for various diagnostic applications. However accurate decomposing more than two types of material remains challenging using conventional methods. Deep learning (DL) methods have shown promise to improve the MMD performance, but typical approaches of conducing DL-MMD in the image domain fail to fully utilize projection information or under iterative setup are computationally inefficient in both training and prediction. In this work, we present a clinical-applicable MMD (>2) framework rFast-MMDNet, operating with raw projection data in non-recursive setup, for breast tissue differentiation. rFast-MMDNet is a two-stage algorithm, including stage-one SinoNet to perform dual energy projection decomposition on tissue sinograms and stage-two FBP-DenoiseNet to perform domain adaptation and image post-processing. rFast-MMDNet was tested on a 2022 DL-Spectral-Challenge breast phantom dataset. The two stages of rFast-MMDNet were evaluated separately and then compared with four noniterative reference methods including a direct inversion method (AA-MMD), an image domain DL method (ID-UNet), AA-MMD/ID-UNet + DenoiseNet and a sinogram domain DL method (Triple-CBCT). Our results show that models trained from information stored in DE transmission domain can yield high-fidelity decomposition of the adipose, calcification, and fibroglandular materials with averaged RMSE, MAE, negative PSNR, and SSIM of 0.004+/-~0, 0.001+/-~0, -45.027+/-~0.542, and 0.002+/-~0 benchmarking to the ground truth, respectively. Training of entire rFast-MMDNet on a 4xRTX A6000 GPU cluster took a day with inference time <1s. All DL methods generally led to more accurate MMD than AA-MMD. rFast-MMDNet outperformed Triple-CBCT, but both are superior to the image-domain based methods.

eess.IV

Learning Dynamic MRI Reconstruction with Convolutional Network Assisted Reconstruction Swin Transformer

Dynamic magnetic resonance imaging (DMRI) is an effective imaging tool for diagnosis tasks that require motion tracking of a certain anatomy. To speed up DMRI acquisition, k-space measurements are commonly undersampled along spatial or spatial-temporal domains. The difficulty of recovering useful information increases with increasing undersampling ratios. Compress sensing was invented for this purpose and has become the most popular method until deep learning (DL) based DMRI reconstruction methods emerged in the past decade. Nevertheless, existing DL networks are still limited in long-range sequential dependency understanding and computational efficiency and are not fully automated. Considering the success of Transformers positional embedding and "swin window" self-attention mechanism in the vision community, especially natural video understanding, we hereby propose a novel architecture named Reconstruction Swin Transformer (RST) for 4D MRI. RST inherits the backbone design of the Video Swin Transformer with a novel reconstruction head introduced to restore pixel-wise intensity. A convolution network called SADXNet is used for rapid initialization of 2D MR frames before RST learning to effectively reduce the model complexity, GPU hardware demand, and training time. Experimental results in the cardiac 4D MR dataset further substantiate the superiority of RST, achieving the lowest RMSE of 0.0286 +/- 0.0199 and 1 - SSIM of 0.0872 +/- 0.0783 on 9 times accelerated validation sequences.

eess.IV

2D antiscatter grid and scatter sampling based CBCT pipeline for image guided radiation therapy

Poor tissue visualization and quantitative accuracy in CBCT is a major barrier in expanding the role of CBCT imaging from target localization to quantitative treatment monitoring and plan adaptations in radiation therapy sessions. To further improve image quality in CBCT, 2D antiscatter grid based scatter rejection was combined with a raw data processing pipeline and iterative image reconstruction. The culmination of these steps was referred as quantitative CBCT, qCBCT. qCBCT data processing steps include 2D antiscatter grid implementation, measurement based residual scatter, image lag, and beam hardening correction for offset detector geometry CBCT with a bow tie filter. Images were reconstructed with iterative image reconstruction to reduce image noise. To evaluate image quality, qCBCT acquisitions were performed using a variety of phantoms to investigate the effect of object size and its composition on image quality. qCBCT image quality was benchmarked against clinical CBCT and MDCT images. Addition of image lag and beam hardening correction to scatter suppression reduced HU degradation in qCBCT by 10 HU and 40 HU, respectively. When compared to gold standard MDCT, mean HU errors in qCBCT and clinical CBCT were 10 HU and 27 HU, respectively. HU inaccuracy due to change in phantom size was 22 HU and 85 HU in qCBCT and clinical CBCT images, respectively. With iterative reconstruction, contrast to noise ratio improved by a factor of 1.25 when compared to clinical CBCT protocols. Robust artifact and noise suppression in qCBCT images can reduce the image quality gap between CBCT and MDCT, improving the promise of qCBCT in fulfilling the tasks that demand high quantitative accuracy, such as CBCT based dose calculations and treatment response assessment in image guided radiation therapy.

physics.med-ph

An Efficient and Robust Method for Chest X-Ray Rib Suppression that Improves Pulmonary Abnormality Diagnosis

Suppression of thoracic bone shadows on chest X-rays (CXRs) has been indicated to improve the diagnosis of pulmonary disease. Previous approaches can be categorized as unsupervised physical and supervised deep learning models. Nevertheless, with physical models able to preserve morphological details but at the cost of extremely long processing time, existing DL methods face challenges of gathering sufficient/qualitative ground truth (GT) for robust training, thus leading to failure in maintaining clinically acceptable false positive rates. We hereby propose a generalizable yet efficient workflow of two stages: (1) training pairs generation with GT bone shadows eliminated in by a physical model in spatially transformed gradient fields. (2) fully supervised image denoising network training on stage-one datasets for fast rib removal on incoming CXRs. For step two, we designed a densely connected network called SADXNet, combined with peak signal to noise ratio and multi-scale structure similarity index measure objective minimization to suppress bony structures. The SADXNet organizes spatial filters in U shape (e.g., X=7; filters = 16, 64, 256, 512, 256, 64, 16) and preserves the feature map dimension throughout the network flow. Visually, SADXNet can suppress the rib edge and that near the lung wall/vertebra without jeopardizing the vessel/abnormality conspicuity. Quantitively, it achieves RMSE of ~0 during testing with one prediction taking <1s. Downstream tasks including lung nodule detection as well as common lung disease classification and localization are used to evaluate our proposed rib suppression mechanism. We observed 3.23% and 6.62% area under the curve (AUC) increase as well as 203 and 385 absolute false positive decrease for lung nodule detection and common lung disease localization, separately.

eess.IV

To what extent can Plug-and-Play methods outperform neural networks alone in low-dose CT reconstruction

The Plug-and-Play (PnP) framework was recently introduced for low-dose CT reconstruction to leverage the interpretability and the flexibility of model-based methods to incorporate various plugins, such as trained deep learning (DL) neural networks. However, the benefits of PnP vs. state-of-the-art DL methods have not been clearly demonstrated. In this work, we proposed an improved PnP framework to address the previous limitations and develop clinical-relevant segmentation metrics for quantitative result assessment. Compared with the DL alone methods, our proposed PnP framework was slightly inferior in MSE and PSNR. However, the power spectrum of the resulting images better matched that of full-dose images than that of DL denoised images. The resulting images supported higher accuracy in airway segmentation than DL denoised images for all the ten patients in the test set, more substantially on the airways with a cross-section smaller than 0.61cm$^2$, and outperformed the DL denoised images for 45 out of 50 lung lobes in lobar segmentation. Our PnP method proved to be significantly better at preserving the image texture, which translated to task-specific benefits in automated structure segmentation and detection.

eess.IV

A novel 3D multi-path DenseNet for improving automatic segmentation of glioblastoma on pre-operative multi-modal MR images

Convolutional neural networks have achieved excellent results in automatic medical image segmentation. In this study, we proposed a novel 3D multi-path DenseNet for generating the accurate glioblastoma (GBM) tumor contour from four multi-modal pre-operative MR images. We hypothesized that the multi-path architecture could achieve more accurate segmentation than a single-path architecture. 258 GBM patients were included in this study. Each patient had four MR images (T1-weighted, contrast-enhanced T1-weighted, T2-weighted, and FLAIR) and the manually segmented tumor contour. We built a 3D multi-path DenseNet that could be trained to generate the corresponding GBM tumor contour from the four MR images. A 3D single-path DenseNet was also built for comparison. Both DenseNets were based on the encoder-decoder architecture. All four images were concatenated and fed into a single encoder path in the single-path DenseNet, while each input image had its own encoder path in the multi-path DenseNet. The patient cohort was randomly split into a training set of 180 patients, a validation set of 39 patients, and a testing set of 39 patients. Model performance was evaluated using the Dice similarity coefficient (DSC), average surface distance (ASD), and 95% Hausdorff distance (HD95%). Wilcoxon signed-rank tests were conducted to examine the model differences. The single-path DenseNet achieved a DSC of 0.911$\pm$0.060, ASD of 1.3$\pm$0.7 mm, and HD95% of 5.2$\pm$7.1 mm, while the multi-path DenseNet achieved a DSC of 0.922$\pm$0.041, ASD of 1.1$\pm$0.5 mm, and HD95% of 3.9$\pm$3.3 mm. The p-values of all Wilcoxon signed-rank tests were less than 0.05. Both 3D DenseNets generated GBM tumor contours in good agreement with the manually segmented contours from multi-modal MR images. The multi-path DenseNet achieved more accurate tumor segmentation than the single-path DenseNet.

physics.med-ph

An automatic deep learning-based workflow for glioblastoma survival prediction using pre-operative multimodal MR images

We proposed a fully automatic workflow for glioblastoma (GBM) survival prediction using deep learning (DL) methods. 285 glioma (210 GBM, 75 low-grade glioma) patients were included. 163 of the GBM patients had overall survival (OS) data. Every patient had four pre-operative MR scans and manually drawn tumor contours. For automatic tumor segmentation, a 3D convolutional neural network (CNN) was trained and validated using 122 glioma patients. The trained model was applied to the remaining 163 GBM patients to generate tumor contours. The handcrafted and DL-based radiomic features were extracted from auto-contours using explicitly designed algorithms and a pre-trained CNN respectively. 163 GBM patients were randomly split into training (n=122) and testing (n=41) sets for survival analysis. Cox regression models with regularization techniques were trained to construct the handcrafted and DL-based signatures. The prognostic power of the two signatures was evaluated and compared. The 3D CNN achieved an average Dice coefficient of 0.85 across 163 GBM patients for tumor segmentation. The handcrafted signature achieved a C-index of 0.64 (95% CI: 0.55-0.73), while the DL-based signature achieved a C-index of 0.67 (95% CI: 0.57-0.77). Unlike the handcrafted signature, the DL-based signature successfully stratified testing patients into two prognostically distinct groups (p-value<0.01, HR=2.80, 95% CI: 1.26-6.24). The proposed 3D CNN generated accurate GBM tumor contours from four MR images. The DL-based signature resulted in better GBM survival prediction, in terms of higher C-index and significant patient stratification, than the handcrafted signature. The proposed automatic radiomic workflow demonstrated the potential of improving patient stratification and survival prediction in GBM patients.

physics.med-ph

Fully Automated Multi-Organ Segmentation in Abdominal Magnetic Resonance Imaging with Deep Neural Networks

Segmentation of multiple organs-at-risk (OARs) is essential for radiation therapy treatment planning and other clinical applications. We developed an Automated deep Learning-based Abdominal Multi-Organ segmentation (ALAMO) framework based on 2D U-net and a densely connected network structure with tailored design in data augmentation and training procedures such as deep connection, auxiliary supervision, and multi-view. The model takes in multi-slice MR images and generates the output of segmentation results. Three-Tesla T1 VIBE (Volumetric Interpolated Breath-hold Examination) images of 102 subjects were collected and used in our study. Ten OARs were studied, including the liver, spleen, pancreas, left/right kidneys, stomach, duodenum, small intestine, spinal cord, and vertebral bodies. Two radiologists manually labeled and obtained the consensus contours as the ground-truth. In the complete cohort of 102, 20 samples were held out for independent testing, and the rest were used for training and validation. The performance was measured using volume overlapping and surface distance. The ALAMO framework generated segmentation labels in good agreement with the manual results. Specifically, among the 10 OARs, 9 achieved high Dice Similarity Coefficients (DSCs) in the range of 0.87-0.96, except for the duodenum with a DSC of 0.80. The inference completes within one minute for a 3D volume of 320x288x180. Overall, the ALAMO model matches the state-of-the-art performance. The proposed ALAMO framework allows for fully automated abdominal MR segmentation with high accuracy and low memory and computation time demands.

eess.IV