arXiv ScienceSearch

arXiv subjects

Damien Chablat

Publications and source records attributed to Damien Chablat.

At least 19 recordsLinked to original sources

Quasi-static analysis of passive stability in a novel underactuated multi-finger hand

Underactuated robotic hands achieve adaptive and robust grasping with a reduced number of actuators, but predicting the stable equilibrium pose of the grasped object remains a significant challenge. This paper introduces a quasi-static analytical approach to assess passive stability in underactuated multi-finger hands. A novel three-finger hand architecture integrating a differential spring-loaded slider mechanism is introduced, enabling versatile and adaptive grasping. The study focuses on how the differential mechanism influences the overall grasp behavior and analyzes the effect of object size on the stable equilibrium configurations for two canonical grasp types: cylindrical and spherical.

cs.RO

Toward an~Integrated Cognitive--Ergonomic Architecture for~Human--Machine Interaction: Combining Cognitive Models with~Human Factors Ergonomics

This paper presents an integrated approach to modeling human competencies by combining the theoretical foundations of cognitive architectures with principles from Human Factors Ergonomics (HFE). Through a comparative analysis of established cognitive models-SOAR, ACT-R, LIDA, and COCOM-we synthesize a tailored architecture designed to address the complexities of human-machine interaction (HMI) in dynamic environments. By contextualizing this model within ergonomic frameworks, we elucidate the mechanisms underlying decision-making, skill acquisition, and adaptive behavior, bridging the gap between cognitive theory and applied system design. Our framework is empirically grounded in industrial robotics applications, where operator expertise, normative knowledge, and real-time feedback loops are critical. The proposed architecture not only enhances the cognitive alignment of HMI systems but also provides a scalable methodology for designing intelligent, human-centered interfaces in high-stakes environments. This work advances both the theoretical understanding of human competencies and the practical implementation of adaptive, ergonomically optimized systems.

cs.RO

Dynamic Modeling of a Welding Torch Umbilical and Its Impact on Robot Dynamics

Robotic welding is widely used in industrial manufacturing, where the welding torch is often connected to the generator through an external umbilical. With the increasing deployment of lightweight and collaborative robots, the dynamic influence of this umbilical can significantly affect the robot motion and the actuation forces. This paper proposes a constrained multibody dynamic model of a welding umbilical, represented as a serial chain of rigid bodies interconnected by passive joints with elastic and dissipative effects. Prescribed motions at the distal anchor point are introduced through holonomic kinematic constraints. The equations of motion are reduced by projecting the dynamics onto the subspace of admissible velocities, yielding an efficient formulation free of Lagrange multipliers. The reaction wrench exerted by the umbilical on the robot is explicitly recovered. A planar case study illustrates the approach.

cs.RO

The Twist Decomposition of Serial Robots Under Lower-Mobility Tasks

This paper introduces a twist decomposition framework for serial manipulators performing lower mobility tasks. Rather than relying on Jacobian null-space projections, the method separates the end-effector twist into task and redundant components using geometrically defined twist projectors. This formulation provides a direct and intuitive distinction between task-relevant and task-irrelevant motions in operational space, enabling a compact inverse kinematics scheme that naturally handles both manipulator and task redundancy.

cs.RO

Design and stability analysis of an underactuated hand with passively rotating fingers

This paper presents an innovative design and stability analysis of an underactuated robotic finger with spatial mobility, designed to enhance gripping dexterity in robotic hands. The finger architecture incorporates a revolute joint at its base, enabling passive spatial rotation that facilitates both cylindrical and spherical grasping. With only two phalanges per finger, the design simplifies kinematic complexity while supporting precision and enveloping grasps. Stability criteria, based on the moment at the finger base joint induced by contact forces, are introduced to ensure reliable object gripping and prevent ejection during manipulation. The study also examines a differential mechanism that distributes a single actuation torque across multiple fingers, allowing adaptive and coordinated motion. This mechanism enhances the hand's ability to grasp diverse object shapes with minimal pre-grasp adjustments, leveraging passivity for autonomous adaptation. Theoretical findings are experimentally validated using a fully mechanical prototype, demonstrating versatility in performing cylindrical, spherical, parallel, and enveloping grasps. The integration of underactuation-both within individual fingers and among multiple fingers-reduces mechanical complexity, cost, and control demands while preserving functional adaptability. This work advances the development of compliant robotic hands suitable for applications requiring dexterity and robustness, such as agricultural robotics, logistics, assistive technologies, and waste sorting. Future research will focus on automating actuation and refining control strategies to further improve grasp stability and precision, paving the way for autonomous manipulation in unstructured environments.

cs.RO

Control Architecture and experimental validation of a Novel Surgical Robotic Instrument

Minimally invasive surgery (MIS) reduces patient trauma and shortens recovery time; however, conventional laparoscopic instruments remain constrained by limited range of movements. This work presents the control architecture of a 4-DOF flexible laparoscopic instrument integrating distal bending, independent distal head rotation, shaft rotation, and a gripper, while maintaining a 10 mm diameter compatible with standard trocars. The actuation unit and SpaceMouse teleoperation are implemented on Raspberry Pi 5 with Motoron controllers. An analytical scissor-linkage model is derived and parameterized. The predicted jaw opening corresponds to CAD measurements (MAE 0.13{\textdegree}) and OptiTrack motion capture (MAE 1.43{\textdegree}). Integration with the ATHENA parallel robot is validated through a simulated pancreatic surgery procedure.

cs.RO

Optimizing Robot Positioning Against Placement Inaccuracies: A Study on the Fanuc CRX10iA/L

This study presents a methodology for determining the optimal base placement of a Fanuc CRX10iA/L collaborative robot for a desired trajectory corresponding to an industrial task. The proposed method uses a particle swarm optimization algorithm that explores the search space to find positions for performing the trajectory. An $\alpha$-shape algorithm is then used to draw the borders of the feasibility areas, and the largest circle inscribed is calculated from the Voronoi diagrams. The aim of this approach is to provide a robustness criterion in the context of robot placement inaccuracies that may be encountered, for example, if the robot is placed on a mobile base when the system is deployed by an operator. The approach developed uses an inverse kinematics model to evaluate all initial configurations, then moves the robot end-effector along the reference trajectory using the Jacobian matrix and assigns a score to the attempt. For the Fanuc CRX10iA/L robot, there can be up to 16 solutions to the inverse kinematics model. The calculation of these solutions is not trivial and requires a specific study that planning tools such as MoveIt cannot fully take into account. Additionally, the optimization process must consider constraints such as joint limits, singularities, and workspace limitations to ensure feasible and efficient trajectory execution.

cs.RO

MSA - Technique for Stiffness Modeling of Manipulators with Complex and Hybrid Structures

The paper presents a systematic approach for stiffness modeling of manipulators with complex and hybrid structures using matrix structural analysis. In contrast to previous results, it is suitable for mixed architectures containing closed-loops, flexible links, rigid connections, passive and elastic joints with external loadings and preloadings. The proposed approach produces the Cartesian stiffness matrices in a semi-analytical manner. It presents the manipulator stiffness model as a set of conventional equations describing the link elasticities that are supplemented by a set of constraints describing connections between links. Its allows user straightforward aggregation of stiffness model equations avoiding traditional column/row merging procedures in the extended stiffness matrix. Advantages of this approach are illustrated by stiffness analysis of NaVaRo manipulator.

cs.RO

A Novel Skill Modeling Approach: Integrating Vergnaud's Scheme with Cognitive Architectures

Human-machine interaction is increasingly important in industry, and this trend will only intensify with the rise of Industry 5.0. Human operators have skills that need to be adapted when using machines to achieve the best results. It is crucial to highlight the operator's skills and understand how they use and adapt them [18]. A rigorous description of these skills is necessary to compare performance with and without robot assistance. Predicate logic, used by Vergnaud within Piaget's scheme concept, offers a promising approach. However, this theory doesn't account for cognitive system constraints, such as the timing of actions, the limitation of cognitive resources, the parallelization of tasks, or the activation of automatic gestures contrary to optimal knowledge. Integrating these constraints is essential for representing agent skills understanding skill transfer between biological and mechanical structures. Cognitive architectures models [2] address these needs by describing cognitive structure and can be combined with the scheme for mutual benefit. Welding provides a relevant case study, as it highlights the challenges faced by operators, even highly skilled ones. Welding's complexity stems from the need for constant skill adaptation to variable parameters like part position and process. This adaptation is crucial, as weld quality, a key factor, is only assessed afterward via destructive testing. Thus, the welder is confronted with a complex perception-decision-action cycle, where the evaluation of the impact of his actions is delayed and where errors are definitive. This dynamic underscores the importance of understanding and modeling the skills of operators.

cs.RO

Optimization of Radar Search Patterns for Multiple Scanning Missions in Localized Clutter

Electronic Phased-Array Radars offer new possibilities for Optimization of Radar Search Pattern by using bi-dimensional beam forming and beam steering, along both elevation and azimuth axes. The minimization of the Time-Budget required for multiple Radar scanning missions in localized clutter, under constraints of range and detection probability, can be approximated as a Set Cover Problem. We present a Set Cover Problem approximation for Time-Budget minimization of the Radar Search Pattern, and solved this optimization problem using Integer Programming methods based on Branch\&Bound and linear relaxation.

math.OC

Design Analysis of an Innovative Parallel Robot for Minimally Invasive Pancreatic Surgery

This paper focuses on the design of a parallel robot designed for robotic assisted minimally invasive pancreatic surgery. Two alternative architectures, called ATHENA-1 and ATHENA-2, each with 4 degrees of freedom (DOF) are proposed. Their kinematic schemes are presented, and the conceptual 3D CAD models are illustrated. Based on these, two Finite Element Method (FEM) simulations were performed to determine which architecture has the higher stiffness. A workspace quantitative analysis is performed to further assess the usability of the two proposed parallel architectures related to the medical tasks. The obtained results are used to select the architecture which fit the required design criteria and will be used to develop the experimental model of the surgical robot.

cs.RO

Design of an innovative robotic surgical instrument for circular stapling

Esophageal cancer remains a highly aggressive malignancy with low survival rates, requiring advanced surgical interventions like esophagectomy. Traditional manual techniques, including circular staplers, face challenges such as limited precision, prolonged recovery times, and complications like leaks and tissue misalignment. This paper presents a novel robotic circular stapler designed to enhance the dexterity in confined spaces, improve tissue alignment, and reduce post-operative risks. Integrated with a cognitive robot that serves as a surgeon's assistant, the surgical stapler uses three actuators to perform anvil motion, cutter/stapler motion and allows a 75-degree bending of the cartridge (distal tip). Kinematic analysis is used to compute the stapler tip's position, ensuring synchronization with a robotic system.

cs.RO

A Pillbug-Inspired Morphing Mechanism Covered with Sliding Shells

This research proposes a novel morphing structure with shells inspired by the movement of pillbugs. Instead of the pillbug body, a loopcoupled mechanism based on slider-crank mechanisms is utilized to achieve the rolling up and spreading motion. This mechanism precisely imitates three distinct curves that mimic the shape morphing of a pillbug. To decrease the degree-of-freedom (DOF) of the mechanism to one, scissor mechanisms are added. 3D curved shells are then attached to the tracer points of the morphing mechanism to safeguard it from attacks while allowing it to roll. Through type and dimensional synthesis, a complete system that includes shells and an underlying morphing mechanism is developed. A 3D model is created and tested to demonstrate the proposed system's shape-changing capability. Lastly, a robot with two modes is developed based on the proposed mechanism, which can curl up to roll down hills and can spread to move in a straight line via wheels.

cs.RO

An analysis of higher-order kinematics formalisms for an innovative surgical parallel robot

The paper presents a novel modular hybrid parallel robot for pancreatic surgery and its higher-order kinematics derived based on various formalisms. The classical vector, homogeneous transformation matrices and dual quaternion approaches are studied for the kinematic functions using both classical differentiation and multidual algebra. The algorithms for inverse kinematics for all three studied formalisms are presented for both differentiation and multidual algebra approaches. Furthermore, these algorithms are compared based on numerical stability, execution times and number and type of mathematical functions and operators contained in each algorithm. A statistical analysis shows that there is significant improvement in execution time for the algorithms implemented using multidual algebra, while the numerical stability is appropriate for all algorithms derived based on differentiation and multidual algebra. While the implementation of the kinematic algorithms using multidual algebra shows positive results when benchmarked on a standard PC, further work is required to evaluate the multidual algorithms on hardware/software used for the modular parallel robot command and control.

cs.RO

An innovative mixed reality approach for Robotics Surgery

Robotic-assisted procedures offer numerous advantages over traditional approaches, including improved dexterity, reduced fatigue, minimized trauma, and superior outcomes. However, the main challenge of these systems remains the poor visualization and perception of the surgical field. The goal of this paper is to provide an innovative approach concerning an application able to improve the surgical procedures offering assistance in both preplanning and intraoperative steps of the surgery. The system has been designed to offer a better understanding of the patient through techniques that provide medical images visualization, 3D anatomical structures perception and robotic planning. The application was designed to be intuitive and user friendly, providing an augmented reality experience through the Hololens 2 device. It was tested in laboratory conditions, yielding positive results.

cs.RO

Enhancing Otological Surgery: Co-Designing a Parallel Robot with Surgeon Input

This work presents the development of a parallel manipulator used for otological surgery from the perspective of co-design. Co-design refers to the simultaneous involvement of the end-users (surgeons), stakeholders (designers, ergonomic experts, manufacturers), and experts from the fields of optimization and mechanisms. The role of each member is discussed in detail and the interactions between the stakeholders are presented. Co-design facilitates a reduction in the parameter space considered during mechanism optimization, leading to a more efficient design process. Additionally, the co-design principles help avoid unforeseen errors and help in quicker adaptation of the proposed solution.

cs.RO

Continuous-Time Robust Control for Cancer Treatment Robots

The control system in surgical robots must ensure patient safety and real time control. As such, all the uncertainties which could appear should be considered into an extended model of the plant. After such an uncertain plant is formed, an adequate controller which ensures a minimum set of performances for each situation should be computed. As such, the continuous-time robust control paradigm is suitable for such scenarios. However, the problem is generally solved only for linear and time invariant plants. The main focus of the current paper is to include m-link serial surgical robots into Robust Control Framework by considering all nonlinearities as uncertainties. Moreover, the paper studies an incipient problem of numerical implementation of such control structures.

cs.RO

The control architecture of a spherical robot for Minimally Invasive Surgery

Control systems used in Minimally Invasive Surgery (MIS) play a crucial role in ensuring preci-sion and safety throughout procedures. This paper presents a control architecture developed for a robotic system designed for MIS operations. The modular structure of the control system allows for compatibility with a range of procedures in abdominal and thoracic regions. The proposed control system, employing the master-slave concept, is presented alongside the experimental model. Functional validation is obtained by performing a Siemens NX simulation and comparing the results with several experimental runs using the experimental model of the robot. With its compact size and stiffness, the system holds promise for integration with other robotic systems. Future efforts will be dedicated to exploring and optimizing this potential collaboration to enhance the overall capabilities of robotic-assisted surgery.

cs.RO