arXiv ScienceSearch

arXiv subjects

D. Woolger

Publications and source records attributed to D. Woolger.

2 recordsLinked to original sources

Initial Performance of the TUCAN Magnetically Shielded Room

The TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration has commissioned a large magnetically shielded room to be used for measuring the neutron electric dipole moment (nEDM) to a precision of $10^{-27}~e\mathrm{cm}$. The room is composed of five layers of MuMetal and one layer of copper and sits within the $\lesssim 370~\mu\mathrm{T}$ ambient field produced by the TRIUMF cyclotron. Within this environment, the quasi-static shielding factor was measured to be $3.25(2) \times 10^4$ at $0.01~\mathrm{Hz}$ with an external peak-to-peak perturbation of $2~\mu\mathrm{T}$. Without the large ambient cyclotron field, the shielding factor improves to $3.75(4)\times 10^4$ at the same perturbation amplitude and frequency. After idealization in the cyclotron field, the residual field at the room center was $B = 1.8(2)~\mathrm{nT}$ and the vertical first-order gradient across the central 1~m$^3$ ($dB_{\mathrm{z}}/dz$) was $-279(64)~\mathrm{pT/m}$. With additional improvement to the idealization, and with active compensation, we expect the room to be adequate for a $10^{-27}~e\mathrm{cm}$ nEDM search.

physics.ins-det

Benchtop magnetic shielding for benchmarking atomic magnetometers

Here, a benchtop hybrid magnetic shield containing four mumetal cylinders and nine internal flexible printed circuit boards is designed, constructed, tested, and operated. The shield is designed specifically as a test-bed for building and operating ultra-sensitive quantum magnetometers. The geometry and spacing of the mumetal cylinders are optimized to maximize shielding efficiency while maintaining Johnson noise $<15$ fT/$\sqrt{}$Hz. Experimental measurements at the shield's center show passive shielding efficiency of $\left(1.0\pm0.1\right){\times}10^6$ for a $0.2$ Hz oscillating field applied along the shield's axis. The nine flexible printed circuit boards generate three uniform fields, which all deviate from perfect uniformity by ${\leq}0.5$% along $50$% of the inner shield axis, and five linear field gradients and one second-order gradient, which all deviate by ${\leq}4$% from perfect linearity and curvature, respectively, over measured target regions. Together, the target field amplitudes are adjusted to minimize the remnant static field along $40$% of the inner shield axis, as mapped using an atomic magnetometer. In this region, the active null reduces the norm of the magnitudes of the three uniform fields and six gradients by factors of $19.5$ and $19.8$, respectively, thereby reducing the total static field from $1.68$ nT to $0.23$ nT.

physics.ins-det