arXiv ScienceSearch

arXiv subjects

D. Gooding

Publications and source records attributed to D. Gooding.

16 recordsLinked to original sources

Measurement of reactor antineutrino oscillations with 1.46 ktonne-years of data at SNO+

The SNO+ Collaboration reports new results on reactor antineutrino oscillations using data acquired from May 2022 through July 2025. The spectral analysis of a flux dominated by nuclear reactors at 240, 350, and 355 kilometers yields the mass-squared difference $\Delta m^2_{21}=(7.93^{+0.21}_{-0.24})\times 10^{-5}$ eV$^2$. This result is compatible with and approaches the precision of the only other long-baseline reactor antineutrino measurement, by KamLAND. Combining these measurements, along with those from solar neutrino experiments, the global values of the neutrino mixing parameters become: $\Delta m^2_{21}$ = $(7.63\pm0.17)\times 10^{-5}$ eV$^2$ and $\sin^2{\theta_{12}}=0.310\pm0.012$. The analysis of geoneutrinos at SNO+ is also improved, with a measured signal of 49$^{+13}_{-12}$ TNU.

hep-ex

Cosmogenic Neutron Production in Water at SNO+

Accurate measurement of the cosmogenic muon-induced neutron yield is crucial for constraining a significant background in a wide range of low-energy physics searches. Although previous underground experiments have measured this yield across various cosmogenic muon energies, SNO+ is uniquely positioned due to its exposure to one of the highest average cosmogenic muon energies at $364\,\text{GeV}$. Using ultra-pure water, we have determined a neutron yield of $Y_{n}=(3.38^{+0.23}_{-0.30})\times10^{-4}\,\text{cm}^{2}\text{g}^{-1}\mu^{-1}$ at SNO+. Comparison with simulations demonstrates clear agreement with the FLUKA neutron production model, highlighting discrepancies with the widely used GEANT4 model. Furthermore, this measurement reveals a lower cosmogenic neutron yield than that observed by the SNO experiment, which used heavy water under identical muon flux conditions. This result provides new evidence that nuclear structure and target material composition significantly influence neutron production by cosmogenic muons, offering fresh insight with important implications for the design and background modelling of future underground experiments.

hep-ex

First Evidence of Solar Neutrino Interactions on $^{13}$C

The SNO+ Collaboration reports the first evidence of $^{8}\text{B}$ solar neutrinos interacting on $^{13}\text{C}$ nuclei. The charged current interaction proceeds through $^{13}\text{C} + \nu_e \rightarrow {}^{13}\text{N} + e^-$ which is followed, with a 10 minute half-life, by ${}^{13}\text{N} \rightarrow {}^{13}\text{C} + e^+ +\nu_e .$ The detection strategy is based on the delayed coincidence between the electron and the positron. Evidence for the charged current signal is presented with a significance of 4.2$\sigma$. Using the natural abundance of $^{13}\text{C}$ present in the scintillator, 5.7 tonnes of $^{13}\text{C}$ over 231 days of data were used in this analysis. The 5.6$^{+3.0}_{-2.3}$ observed events in the data set are consistent with the expectation of 4.7$^{+0.6}_{-1.3}$ events. This result is the second real-time measurement of CC interactions of $^{8}\text{B}$ neutrinos with nuclei and constitutes the lowest energy observation of neutrino interactions on $^{13}\text{C}$ generally. This enables the first direct measurement of the CC $\nu_e$ reaction to the ground state of ${}^{13}\text{N}$, yielding an average cross section of $(16.1 ^{+8.5}_{-6.7} (\text{stat.}) ^{+1.6}_{-2.7} (\text{syst.}) )\times 10^{-43}$ cm$^{2}$ over the relevant $^{8}\text{B}$ solar neutrino energies.

nucl-ex

Measurement of reactor antineutrino oscillation at SNO+

The SNO+ collaboration reports its second spectral analysis of reactor antineutrino oscillation using 286 tonne-years of new data. The measured energies of reactor antineutrino candidates were fitted to obtain the second-most precise determination of the neutrino mass-squared difference $\Delta m^2_{21}$ = ($7.96^{+0.48}_{-0.42}$) $\times$ 10$^{-5}$ eV$^2$. Constraining $\Delta m^2_{21}$ and $\sin^2\theta_{12}$ with measurements from long-baseline reactor antineutrino and solar neutrino experiments yields $\Delta m^2_{21}$ = ($7.58^{+0.18}_{-0.17}$) $\times$ 10$^{-5}$ eV$^2$ and $\sin^2\theta_{12} = 0.308 \pm 0.013$. This fit also yields a first measurement of the flux of geoneutrinos in the Western Hemisphere, with $73^{+47}_{-43}$ TNU at SNO+.

hep-ex

Measurement of the $^8$B Solar Neutrino Flux Using the Full SNO+ Water Phase Dataset

The SNO+ detector operated initially as a water Cherenkov detector. The implementation of a sealed covergas system midway through water data taking resulted in a significant reduction in the activity of $^{222}$Rn daughters in the detector and allowed the lowest background to the solar electron scattering signal above 5 MeV achieved to date. This paper reports an updated SNO+ water phase $^8$B solar neutrino analysis with a total livetime of 282.4 days and an analysis threshold of 3.5 MeV. The $^8$B solar neutrino flux is found to be $\left(2.32^{+0.18}_{-0.17}\text{(stat.)}^{+0.07}_{-0.05}\text{(syst.)}\right)\times10^{6}$ cm$^{-2}$s$^{-1}$ assuming no neutrino oscillations, or $\left(5.36^{+0.41}_{-0.39}\text{(stat.)}^{+0.17}_{-0.16}\text{(syst.)} \right)\times10^{6}$ cm$^{-2}$s$^{-1}$ assuming standard neutrino oscillation parameters, in good agreement with both previous measurements and Standard Solar Model Calculations. The electron recoil spectrum is presented above 3.5 MeV.

hep-ex

Initial measurement of reactor antineutrino oscillation at SNO+

The SNO+ collaboration reports its first spectral analysis of long-baseline reactor antineutrino oscillation using 114 tonne-years of data. Fitting the neutrino oscillation probability to the observed energy spectrum yields constraints on the neutrino mass-squared difference $\Delta m^2_{21}$. In the ranges allowed by previous measurements, the best-fit $\Delta m^2_{21}$ is (8.85$^{+1.10}_{-1.33}$) $\times$ 10$^{-5}$ eV$^2$. This measurement is continuing in the next phases of SNO+ and is expected to surpass the present global precision on $\Delta m^2_{21}$ with about three years of data.

hep-ex

Event-by-Event Direction Reconstruction of Solar Neutrinos in a High Light-Yield Liquid Scintillator

The direction of individual $^8$B solar neutrinos has been reconstructed using the SNO+ liquid scintillator detector. Prompt, directional Cherenkov light was separated from the slower, isotropic scintillation light using time information, and a maximum likelihood method was used to reconstruct the direction of individual scattered electrons. A clear directional signal was observed, correlated with the solar angle. The observation was aided by a period of low primary fluor concentration that resulted in a slower scintillator decay time. This is the first time that event-by-event direction reconstruction in high light-yield liquid scintillator has been demonstrated in a large-scale detector.

hep-ex

A Method to Load Tellurium in Liquid Scintillator for the Study of Neutrinoless Double Beta Decay

A method has been developed to load tellurium into liquid scintillator so as to permit searches for neutrinoless double beta decay with high sensitivity. The approach involves the synthesis of an oil-soluble tellurium compound from telluric acid and an organic diol. The process utilises distillable chemicals that can be safely handled underground and affords low radioactive backgrounds, low optical absorption and high light yields at loading levels of at least several percent Te by weight.

physics.ins-det

Evidence of Antineutrinos from Distant Reactors using Pure Water at SNO+

The SNO+ Collaboration reports the first evidence of reactor antineutrinos in a Cherenkov detector. The nearest nuclear reactors are located 240~km away in Ontario, Canada. This analysis uses events with energies lower than in any previous analysis with a large water Cherenkov detector. Two analytical methods are used to distinguish reactor antineutrinos from background events in 190 days of data and yield consistent evidence for antineutrinos with a combined significance of 3.5$\sigma$.

nucl-ex

Improved search for invisible modes of nucleon decay in water with the SNO+ detector

This paper reports results from a search for single and multi-nucleon disappearance from the $^{16}$O nucleus in water within the \snoplus{} detector using all of the available data. These so-called "invisible" decays do not directly deposit energy within the detector but are instead detected through their subsequent nuclear de-excitation and gamma-ray emission. New limits are given for the partial lifetimes: $\tau(n\rightarrow inv) > 9.0\times10^{29}$ years, $\tau(p\rightarrow inv) > 9.6\times10^{29}$ years, $\tau(nn\rightarrow inv) > 1.5\times10^{28}$ years, $\tau(np\rightarrow inv) > 6.0\times10^{28}$ years, and $\tau(pp\rightarrow inv) > 1.1\times10^{29}$ years at 90\% Bayesian credibility level (with a prior uniform in rate). All but the ($nn\rightarrow inv$) results improve on existing limits by a factor of about 3.

hep-ex

A Call to Arms Control: Synergies between Nonproliferation Applications of Neutrino Detectors and Large-Scale Fundamental Neutrino Physics Experiments

The High Energy Physics community can benefit from a natural synergy in research activities into next-generation large-scale water and scintillator neutrino detectors, now being studied for remote reactor monitoring, discovery and exclusion applications in cooperative nonproliferation contexts. Since approximately 2010, US nonproliferation researchers, supported by the National Nuclear Security Administration (NNSA), have been studying a range of possible applications of relatively large (100 ton) to very large (hundreds of kiloton) water and scintillator neutrino detectors. In parallel, the fundamental physics community has been developing detectors at similar scales and with similar design features for a range of high-priority physics topics, primarily in fundamental neutrino physics. These topics include neutrino oscillation studies at beams and reactors, solar, and geological neutrino measurements, supernova studies, and others. Examples of ongoing synergistic work at U.S. national laboratories and universities include prototype gadolinium-doped water and water-based and opaque scintillator test-beds and demonstrators, extensive testing and industry partnerships related to large area fast position-sensitive photomultiplier tubes, and the development of concepts for a possible underground kiloton-scale water-based detector for reactor monitoring and technology demonstrations. Some opportunities for engagement between the two communities include bi-annual Applied Antineutrino Physics conferences, collaboration with U.S. National Laboratories engaging in this research, and occasional NNSA funding opportunities supporting a blend of nonproliferation and basic science R&D, directed at the U.S. academic community.

physics.ins-det

Optical calibration of the SNO+ detector in the water phase with deployed sources

SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light diffusing sphere, with the goal of improving the detector model and the energy response systematic uncertainties. The measured parameters included the water attenuation coefficients, effective attenuation coefficients for the acrylic vessel, and the angular response of the photomultiplier tubes and their surrounding light concentrators, all across different wavelengths. The calibrated detector model was validated using a deployed tagged gamma source, which showed a 0.6% variation in energy scale across the primary target volume.

physics.ins-det

The SNO+ Experiment

The SNO+ experiment is located 2 km underground at SNOLAB in Sudbury, Canada. A low background search for neutrinoless double beta ($0\nu\beta\beta$) decay will be conducted using 780 tonnes of liquid scintillator loaded with 3.9 tonnes of natural tellurium, corresponding to 1.3 tonnes of $^{130}$Te. This paper provides a general overview of the SNO+ experiment, including detector design, construction of process plants, commissioning efforts, electronics upgrades, data acquisition systems, and calibration techniques. The SNO+ collaboration is reusing the acrylic vessel, PMT array, and electronics of the SNO detector, having made a number of experimental upgrades and essential adaptations for use with the liquid scintillator. With low backgrounds and a low energy threshold, the SNO+ collaboration will also pursue a rich physics program beyond the search for $0\nu\beta\beta$ decay, including studies of geo- and reactor antineutrinos, supernova and solar neutrinos, and exotic physics such as the search for invisible nucleon decay. The SNO+ approach to the search for $0\nu\beta\beta$ decay is scalable: a future phase with high $^{130}$Te-loading is envisioned to probe an effective Majorana mass in the inverted mass ordering region.

physics.ins-det

Development, characterisation, and deployment of the SNO+ liquid scintillator

A liquid scintillator consisting of linear alkylbenzene as the solvent and 2,5-diphenyloxazole as the fluor was developed for the SNO+ experiment. This mixture was chosen as it is compatible with acrylic and has a competitive light yield to pre-existing liquid scintillators while conferring other advantages including longer attenuation lengths, superior safety characteristics, chemical simplicity, ease of handling, and logistical availability. Its properties have been extensively characterized and are presented here. This liquid scintillator is now used in several neutrino physics experiments in addition to SNO+.

physics.ins-det

Measurement of neutron-proton capture in the SNO+ water phase

The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV $\gamma$ produced by neutron capture on hydrogen have been made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV $\gamma$. Analysis of the delayed coincidence between the 4.4-MeV $\gamma$ and the 2.2-MeV capture $\gamma$ revealed a neutron detection efficiency that is centered around 50% and varies at the level of 1% across the inner region of the detector, which to our knowledge is the highest efficiency achieved among pure water Cherenkov detectors. In addition, the neutron capture time constant was measured and converted to a thermal neutron-proton capture cross section of $336.3^{+1.2}_{-1.5}$ mb.

physics.ins-det

Light Yield of Perovskite Nanocrystal-Doped Liquid Scintillator

Liquid scintillators doped with metals are needed for a variety of measurements in nuclear and particle physics. Nanoparticles provide a mechanism to dope the scintillator and their unique optical properties could be used to enhance detection capabilities. We present here the first study of lead-based perovskite nanoparticles for this application. Perovskites are an attractive choice due to the versatility of their crystal structure and their ease of synthesis.

physics.ins-det