arXiv ScienceSearch

arXiv subjects

D. Fiorina

Publications and source records attributed to D. Fiorina.

At least 19 recordsLinked to original sources

Dark Matter Sensitivity of the CYGNO Detector with HFO-1234ze Enhanced Gas Mixtures

The CYGNO collaboration introduces an innovative approach to direct dark matter detection, proposing a high-resolution optical Time Projection Chamber. It operates at atmospheric pressure with a He:CF$_{4}$ (60:40) gas mixture and uses a triple Gas Electron Multiplier stage for signal amplification. A key feature is its optical readout system, which captures the scintillation light produced during the electron avalanche. This setup allows 3D event reconstruction by combining the time profile of the light detected by photomultiplier tubes with high-granularity, pixelated X-Y tracking recorded by a scientific camera. The CYGNO experiment's projected sensitivity to both spin-independent and spin-dependent interactions is competitive in the framework of directional dark matter detectors. However, incorporating a hydrogen-based gas would introduce an even lighter target, further improving the detection potential at low dark matter masses. In this work, we present the performance characterization of one of the CYGNO experiment prototypes, MANGO, operated with the standard gas mixture enriched with varying concentrations of HFO-1234ze, a gas with a promising low global warming potential. The study includes measurements of the detector charge gain and scintillation yield for each configuration. In addition, to evaluate the impact of HFO-1234ze on scintillation light quenching, the secondary scintillation spectrum was collected for each gas mixture tested.

physics.ins-det

Performance Optimization and Characterization of 7-pad Resistive PICOSEC Micromegas Detectors

We present a comprehensive characterization of resistive PICOSEC Micromegas detector prototypes, tested under identical conditions, constant drift gap, field configurations, and photocathode at the CERN SPS H4 beam line. This work provides a proof of concept for the use of resistive layer technology in gaseous timing detectors, demonstrating that robustness can be improved without compromising the excellent timing performance of PICOSEC Micromegas. Different resistive architectures and values were explored to optimize stability and ensure reliable long-term operation in challenging experimental environments. The prototype with a 10MΩ resistive layer achieved the best overall performance, with a timing resolution of 22.900 {\pm} 0.002 ps and a spatial resolution of 1.190 {\pm} 0.003 mm, while charge sharing across multiple pads enabled combined timing resolutions below 28 ps. A lower-resistivity (200kΩ) configuration exhibited enhanced charge spread, leading to minor systematic offsets in reconstructed pad centers, yet maintained robust timing and spatial performance. Capacitive charge-sharing architectures improved spatial resolution in some regions but suffered from signal attenuation and nonuniform charge distributions, resulting in slightly degraded timing (33.300 {\pm} 0.002 ps) and complex localization patterns. Mechanical precision, particularly readout planarity and photocathode alignment, was identified as critical for uniform detector response. These studies benchmark the potential of resistive layers for gaseous timing detectors and provide a foundation for scalable designs with optimized timing and spatial resolution across diverse experimental applications.

physics.ins-det

He-CF4-CH4 ternary mixtures as target gas for the CYGNO directional dark matter experiment

The CYGNO collaboration is advancing a high-resolution optical Time Projection Chamber (TPC) for directional dark matter searches and solar neutrino spectroscopy at LNGS. The detector uses a He-40%CF4 gas mixture at atmospheric pressure and a triple-GEM cascade for ionization signal amplification. Scintillation light from GEM electron avalanches is read out using sCMOS cameras, enabling high sensitivity to interactions in the few keV range, alongside precise ionization event tracking and particle identification. This study investigates the effects of adding 3-10% methane to the He-40%CF4 mixture. Methane improves the electrical stability of the TPC, allowing for higher GEM voltages before discharge onset, which compensates for its scintillation quenching and leads to enhanced overall scintillation yield. Compared to prior studies performed with isobutane, methane demonstrates a lower quenching effect on visible and UV photons while maintaining good energy resolution. Importantly, the inclusion of methane lowers the dark matter detection threshold by providing a lighter target and extending track lengths of light nuclear recoils, thus enhancing directional discrimination. These results establish methane as a promising additive for optimizing CYGNO's performance in detecting low-mass dark matter candidates.

physics.ins-det

Simulation of the CYGNO Gaseous TPC Optical Readout

Gaseous Time Projection Chambers with Optical Readout are sensitive detectors suitable for 3D measurement of low-energy O(1 keV) particles and are proposed for detecting rare events such as Dark Matter particle interactions. The CYGNO collaboration is developing such a detector with a high spatial and energy resolution, leveraging an innovative optical readout system. A reliable simulation of the detector response is needed to properly assess the physics reach of this technique and to better understand the performance of the detector in the development phase. Such a simulation cannot entirely rely on existing software packages; indeed, none of the available tools is capable of properly and reliably treating the different phenomena occurring in the detector, from the primary interaction in the gas volume throughout the whole detector response model, including charge transport, light production and propagation, and the response of the optical sensors. In this paper, we present a modeling of the detector response tuned on the CYGNO Optical TPC case; a description of the method is reported together with comparisons with experimental data from the LIME prototype to demonstrate the simulation performances.

physics.ins-det

Upgrade of the Trigger and Data Acquisition System for Continuous Imaging and Multi-Camera Operation in CYGNO

The CYGNO experiment employs an optical readout to image particle interactions in a gaseous Time Projection Chamber (TPC), combining cameras and photomultiplier tubes (PMTs) to achieve high spatial resolution and timing information. This approach enables detailed track reconstruction but poses significant challenges for data acquisition, particularly in view of the next experimental phase, CYGNO-04, which will operate multiple cameras simultaneously. In this paper, we present an upgrade of the CYGNO Trigger and Data Acquisition (T-DAQ) system, developed starting from the LIME configuration and validated on the MANGO prototype. The upgrade introduces a continuous imaging acquisition mode, substantially reducing the camera dead time, together with an extended trigger time-tagging scheme that provides a robust global time reference for PMT signals. A synchronous multi-camera DAQ architecture is also implemented and tested, enabling coordinated operation of multiple optical sensors without a master camera. The performance of the upgraded system is validated through dedicated tests, demonstrating stable continuous acquisition, reliable time-tagging, and consistent synchronization across multiple cameras. These results establish a solid and scalable foundation for the CYGNO-04 DAQ and represent a key step toward efficient data acquisition in future large-scale optical TPC detectors.

physics.ins-det

Characterization of field cage and cathode for low radioactivity operation with the CYGNO experiment

Dark matter, which is considered to account for approximately the 27% of the Universe's energy-mass content, remains an open issue in modern particle physics along with its composition. The CYGNO Experiment aims to exploit an innovative approach applied to the direct detection search of low energy nuclear recoils possibly induced by cold particle-like dark matter candidates. CYGNO employs a directional detector based on a Time Projection Chamber (TPC) filled with a He:CF$_{4}$ gas mixture and equipped with an optical readout. Currently, the CYGNO Collaboration is constructing the detector demonstrator, CYGNO-04, in Hall F at Laboratori Nazionali del Gran Sasso (LNGS). This 0.4 m$^3$ detector has the goal of proving the scalability of the technology and assessing the physics and radiopurity capabilities. Given the low radioactivity requirements, especially in internal components such as field cage and cathode, the reduction of material while keeping the correct electrical behavior is paramount. In this paper, we present the validation of several internal components, mainly focusing on the field cage material and support structure. The tests included geometrical asymmetries in the electric field response, collection efficiency as well as measurement of known physical quantities. A preferred configuration is found with a structure based on Nylon material which supports a PET or Kapton sheet with copper strips deposited on.

physics.ins-det

Fast reconstruction-based ROI triggering via anomaly detection in the CYGNO optical TPC

Optical-readout Time Projection Chambers (TPCs) produce megapixel-scale images whose fine-grained topological information is essential for rare-event searches, but whose size challenges real-time data selection. We present an unsupervised, reconstruction-based anomaly-detection strategy for fast Region-of-Interest (ROI) extraction that operates directly on minimally processed camera frames. A convolutional autoencoder trained exclusively on pedestal images learns the detector noise morphology without labels, simulation, or fine-grained calibration. Applied to standard data-taking frames, localized reconstruction residuals identify particle-induced structures, from which compact ROIs are extracted via thresholding and spatial clustering. Using real data from the CYGNO optical TPC prototype, we compare two pedestal-trained autoencoder configurations that differ only in their training objective, enabling a controlled study of its impact. The best configuration retains (93.0 +/- 0.2)% of reconstructed signal intensity while discarding (97.8 +/- 0.1)% of the image area, with an inference time of approximately 25 ms per frame on a consumer GPU. The results demonstrate that careful design of the training objective is critical for effective reconstruction-based anomaly detection and that pedestal-trained autoencoders provide a transparent and detector-agnostic baseline for online data reduction in optical TPCs.

physics.ins-det

Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with $10 \times 10\ \mathrm{cm}^{2}$ active area

The $\upmu$RWELL-PICOSEC detector, which combines a $\upmu$RWELL gaseous amplification structure with a Cherenkov radiator and photocathode, is a novel approach to acheive fast and precise timing in gaseous detectors. With timing precision at the level of tens of picoseconds, this technology is particularly suited for time-of-flight (TOF) applications in particle physics and potentially medical imaging. Beam tests with a 150~GeV/$c$ muon beam have been carried out on a large-area (10~$\times$~10~cm$^{2}$) prototype equipped with a cesium iodide (CsI) photocathode. Using an oscilloscope-based single-channel readout, timing measurements on two individual pads of the detector have yielded resolutions of $\approx$ 48 ps and $\approx$ 52 ps under different biasing conditions respectively.

physics.ins-det

The CYGNO experiment: a gaseous TPC with optical readout for rare events searches

The CYGNO collaboration is developing a novel strategy for directional Dark Matter searches based on a gaseous Time Projection Chamber (TPC). The detector is optimized for the exploration of light (0.5-50 GeV) WIMPs-like particles and employs a He/CF4 gas mixture at atmospheric pressure, sensitive to both spin-dependent and spin-independent interactions. A key feature of the project is its optical readout, which relies on photon detection rather than charge collection. In CYGNO detectors, electrons released by ionizing tracks drift toward an amplification stage of three Gas Electron Multipliers (GEMs). The electron avalanches generate scintillation light that is captured by scientific CMOS (sCMOS) cameras for high-resolution two-dimensional imaging and by Photomultiplier Tubes (PMTs) that provide a precise time profile along the drift direction. This allows a 3D event reconstruction, detailed energy deposition mapping, and effective topology and head-to-tail discrimination. Building on the achievements of the 50 L prototype (LIME), which successfully operated underground at LNGS, the next step is the deployment of a 0.4 m3 demonstrator, CYGNO-04, to be completed in 2026. The demonstrator will validate scalability and confirm the advantages of the proposed technique. Recent results from LIME highlight strong progress in 3D tracking and particle identification. The current status of CYGNO-04 and its role in advancing the program will be presented as well.

physics.ins-det

Trigger Optimization and Event Classification for Dark Matter Searches in the CYGNO Experiment Using Machine Learning

The CYGNO experiment employs an optical-readout Time Projection Chamber (TPC) to search for rare low-energy interactions using finely resolved scintillation images. While the optical readout provides rich topological information, it produces large, sparse megapixel images that challenge real-time triggering, data reduction, and background discrimination. We summarize two complementary machine-learning approaches developed within CYGNO. First, we present a fast and fully unsupervised strategy for online data reduction based on reconstruction-based anomaly detection. A convolutional autoencoder trained exclusively on pedestal images (i.e. frames acquired with GEM amplification disabled) learns the detector noise morphology and highlights particle-induced structures through localized reconstruction residuals, from which compact Regions of Interest (ROIs) are extracted. On real prototype data, the selected configuration retains (93.0 +/- 0.2)% of reconstructed signal intensity while discarding (97.8 +/- 0.1)% of the image area, with ~25 ms per-frame inference time on a consumer GPU. Second, we report a weakly supervised application of the Classification Without Labels (CWoLa) framework to data acquired with an Americium--Beryllium neutron source. Using only mixed AmBe and standard datasets (no event-level labels), a convolutional classifier learns to identify nuclear-recoil-like topologies. The achieved performance approaches the theoretical limit imposed by the mixture composition and isolates a high-score population with compact, approximately circular morphologies consistent with nuclear recoils.

physics.ins-det

Spatial resolution improvement of PICOSEC Micromegas precise timing detectors

The combination of a Cherenkov radiator with a semi-transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolution of better than 15ps. While tileable prototypes with 10x10 channels feature 1x1 cm^2 readout pads, finer readout granularity can be used to improve the spatial resolution. We report on the study of high readout granularity PICOSEC Micromegas prototypes which achieve around 0.5mm spatial resolution with 3.5mm large pads. No significant improvement was found when readout pad size was further reduced to 2.2mm. The timing resolution of the leading pad was found to be slightly degraded but remained better than 20ps for a medium granularity prototype. The achieved spatial resolution can enable PICOSEC Micromegas to be used as precise timing and moderate resolution tracking detector simultaneously.

physics.ins-det

First Optical Observation of Negative Ion Drift at Surface Pressure

We report the first observation of Negative Ion Drift (NID) at surface pressure of $900 \pm 7$ mbar at Laboratori Nazionali del Gran Sasso in a He:CF$_4$:SF$_6$ mixture using an optically read out Time Projection Chamber (TPC) within the CYGNO/INITIUM project. We present the first PMT waveform analysis in the NID regime, interpreting the temporal light pattern through a model that combines track geometry and charge transport. The inferred drift velocities correspond to mobilities of O(cm$^2$ V$^{-1}$ s$^{-1}$), consistent with negative ion transport. The observed linear scaling of the time extension mean with drift distance reveals the presence of a faster minority charge carrier population in addition to the dominant SF$_6^-$ species, drifting at a $\sim$25\% higher velocity under external inputs. These results demonstrate multi-species negative ion drift operation at surface pressure in a He:CF$_4$:SF$_6$ mixture and open a concrete path toward large scale, low diffusion optical TPCs for rare event searches.

physics.ins-det

Design and Performance of a 96-channel Resistive PICOSEC Micromegas Detector for ENUBET

The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector that achieves picosecond-level timing by coupling a Cherenkov radiator, typically an MgF2 crystal, to a Micromegas-based photodetector with a photocathode. This configuration allows the fast photoelectron-induced signal to suppress the intrinsic time jitter of gaseous detectors, enabling sub-20 ps timing precision while preserving the robustness and scalability of micro-pattern gaseous detector technologies. The 96-pad PICOSEC-MM detector is a large-area demonstrator optimized for precision timing in high-energy physics, building on research and development insights from earlier 7-pad resistive prototypes to validate scalability, uniformity, and robustness for the ENUBET project. It employs a 2.5 nm diamond-like carbon photocathode and a Micromegas board with a surface resistivity of 10 megaohms per square, and was characterized using 150 GeV/c muons at the CERN SPS beamline, with one-third of the active area instrumented per run. A dedicated alignment procedure for multi-pad PICOSEC-MM systems was used to reconstruct pad centers and merge measurements across regions, yielding a timing resolution of 43 ps and uniform signal arrival time distributions over the tested area. Mechanical flatness was identified as a key factor, with planarity tolerances within 10 micrometers required to maintain good timing resolution, and the successful operation of the 96-pad demonstrator confirms the scalability of the PICOSEC-MM concept toward robust, high-granularity, picosecond-level gaseous timing detectors for monitored neutrino beam experiments such as ENUBET.

physics.ins-det

Characterization of cutting-edge CMOS Active Pixel sensors within the CYGNO Experiment

Time Projection Chambers equipped with Gas Electron Multipliers and optical readout by scientific CMOS cameras are a promising technology for low-energy particle detection, as demonstrated by the CYGNO experiment. To help identify the optimal CYGNO detector configuration, we performed a detailed characterization of two state-of-the-art scientific CMOS sensors, focusing on dark-signal behavior across different exposure times and on detection sensitivity, assessed using the well-defined X-ray emissions from a 55Fe source, which reproduce the low-light conditions expected in CYGNO. CYGNO currently employs a very low-noise Hamamatsu sensor, the ORCA-Fusion, for testing and validation of its detection system. Hamamatsu has recently introduced two new sensors that may be of interest for future upgrades. The first is an improved version of the current model, the ORCA-Fusion-BT, featuring a back-illuminated design that reaches a quantum efficiency of up to 95% at 550 nm. The second is a next-generation sensor, the ORCA-Quest. Although its peak quantum efficiency is not as high as that of the Fusion-BT, it offers high sensitivity over a broader spectral range, extending into the ultraviolet region, and provides ultra-low readout noise of 0.27 electrons, about 2.6 times lower than that of the Fusion family. These two sensors therefore represent a significant opportunity to enhance the performance of scientific experiments, including those conducted by the CYGNO collaboration. This document presents a comprehensive characterization of these sensors to evaluate their relevance for experiments operating in photon-limited environments and their suitability for integration into the CYGNO detector system.

physics.ins-det

PICOSEC Micromegas Precise-timing Detectors: Development towards Large-Area and Integration

PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector conceprt was successfully demonstrated through a single-channel prototype, achieving sub-25 ps time resolution with Minimum Ionizing Particles (MIPs). A series of studies followed, aimed at developing robust, large-area, and scalable detectors with high time resolution, complemented by specialized fast-response readout electronics. This work presents recent advancements towards large-area resistive PICOSEC MM, including 10 $\times$ 10 $\text{cm}^2$ area prototypes and a 20 $\times$ 20 $\text{cm}^2$ prototype, which features the jointing of four photocathodes. The time resolution of these detector prototypes was tested during the test beam, achieved a timing performance of around 25 ps for individual pads in MIPs. Meanwhile, customized electronics have been developed dedicated to the high-precision time measurement of the large-area PICOSEC MM. The performance of the entire system was evaluated during the test beam, demonstrating its capability for large-area integration. These advancements highlight the potential of PICOSEC MM to meet the stringent requirements of future particle physics experiments.

physics.ins-det

Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a~time resolution below 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B4C), is pursued. Results from prototypes equipped with DLC and B4C photocathodes exhibited a~time resolution of approximately 32 ps and 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.

physics.ins-det

Enhancing the light yield of He:CF$_4$ based gaseous detector

The CYGNO experiment aims to build a large ($\mathcal{O}(10)$ m$^3$) directional detector for rare event searches, such as nuclear recoils (NRs) induced by dark matter (DM), such as weakly interactive massive particles (WIMPs). The detector concept comprises a time projection chamber (TPC), filled with a He:CF$_4$ 60/40 scintillating gas mixture at room temperature and atmospheric pressure, equipped with an amplification stage made of a stack of three gas electron multipliers (GEMs) which are coupled to an optical readout. The latter consists in scientific CMOS (sCMOS) cameras and photomultipliers tubes (PMTs). The maximisation of the light yield of the amplification stage plays a major role in the determination of the energy threshold of the experiment. In this paper, we simulate the effect of the addition of a strong electric field below the last GEM plane on the GEM field structure and we experimentally test it by means of a 10$\times$10 cm$^2$ readout area prototype. The experimental measurements analyse stacks of different GEMs and helium concentrations in the gas mixture combined with this extra electric field, studying their performances in terms of light yield, energy resolution and intrinsic diffusion. It is found that the use of this additional electric field permits large light yield increases without degrading intrinsic characteristics of the amplification stage with respect to the regular use of GEMs.

physics.ins-det

PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30 ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20 ps respectively.

physics.ins-det