arXiv ScienceSearch

arXiv subjects

D. Baxter

Publications and source records attributed to D. Baxter.

At least 19 recordsLinked to original sources

Measuring quasiparticle dynamics for particle impact reconstruction in a superconducting qubit chip

Quasiparticle poisoning following particle impacts poses a significant challenge to the development of fault-tolerant superconducting quantum computers, as a sudden excess of quasiparticles can simultaneously degrade the coherence of multiple qubits across large device arrays. In this work, we present a statistical analysis that models the time evolution of radiation-induced qubit energy relaxation through quasiparticle density dynamics. This study provides insight into quasiparticle loss processes by distinguishing between recombination and trapping decay channels and assessing their respective impact on qubit performance. We precisely measure quasiparticle recombination in multiple transmon qubits and uncover an unexpected dependence of qubit relaxation dynamics on deposited energy. By linking correlated relaxation events across qubits to ballistic phonon propagation, we introduce a statistical localization approach to extract the energy deposited in the substrate, which is in good agreement with Monte Carlo simulation. This work establishes the quantitative framework for using an arbitrary subset of superconducting transmon qubits in a QPU as energy-resolving witness particle detectors.

quant-ph

A First Demonstration of the SQUAT Detector Architecture: Direct Measurement of Resonator-Free Charge-Sensitive Transmons

The Superconducting Quasiparticle-Amplifying Transmon (SQUAT) is a new sensor architecture for THz (meV) detection based on a weakly charge-sensitive transmon directly coupled to a transmission line. In such devices, energy depositions break Cooper pairs in the qubit capacitor islands, generating quasiparticles. Quasiparticles that tunnel across the Josephson junction change the transmon qubit parity, generating a measurable signal. In this paper, we present the design of first-generation SQUATs and demonstrate an architecture validation. We summarize initial characterization measurements made with prototype devices, comment on background sources that influence the observed parity-switching rate, and present experimental results showing simultaneous detection of charge and quasiparticle signals using aluminum-based SQUATs.

physics.ins-det

Calibration Plan for the SBC 10-kg Liquid Argon Detector with 100 eV Target Threshold

The Scintillating Bubble Chamber (SBC) Collaboration is designing a new generation of low background, noble liquid bubble chamber experiments with sub-keV nuclear recoil threshold. These experiments combine the electronic recoil blindness of a bubble chamber with the energy resolution of noble liquid scintillation, and maintain electron recoil discrimination at higher degrees of superheat (lower nuclear recoil thresholds) than Freon-based bubble chambers. A 10-kg liquid argon bubble chamber has the potential to set world leading limits on the dark matter nucleon cross-section for $O(\mathrm{GeV}/c^{2})$ masses, and to perform a high statistics coherent elastic neutrino nuclear scattering measurement with reactor neutrinos. This work presents a detailed calibration plan to measure the detector response of these experiments, combining photoneutron scattering with two new techniques to induce sub-keV nuclear recoils: nuclear Thomson scattering and thermal neutron capture.

physics.ins-det

Community Report from the 2025 SNOLAB Future Projects Workshop

SNOLAB hosts a biannual Future Projects Workshop (FPW) with the goal of encouraging future project stakeholders to present ideas, concepts, and needs for experiments or programs that could one day be hosted at SNOLAB. The 2025 FPW was held in the larger context of a 15-year planning exercise requested by the Canada Foundation for Innovation. This report collects input from the community, including both contributions to the workshop and contributions that could not be scheduled in the workshop but nonetheless are important to the community.

hep-ex

Absorption of Fermionic Dark Matter in the PICO-60 C$_{3}$F$_{8}$ Bubble Chamber

Fermionic dark matter absorption on nuclear targets via neutral current interactions is explored using a non-relativistic effective field theory framework. An analysis of data from the PICO-60 C$_{3}$F$_{8}$ bubble chamber sets leading constraints on spin-independent absorption for dark matter masses below 23 MeV/$\textit{c}^2$ and establishes the first limits on spin-dependent absorptive interactions. These results demonstrate the sensitivity of bubble chambers to low-mass dark matter and underscore the importance of absorption searches in expanding the parameter space of direct detection experiments.

hep-ex

Broadband Optical Modulation and Control at Millikelvin Temperatures

A universal experimental challenge when studying radiation effects on cryogenic devices is to precisely and accurately characterize the position-dependent device response very near the energy detection threshold. We have developed a compact cryogenic optical beam steering system that can be used to generate O({\mu}s) pulses of small numbers of photons over the energy range of 1.2 - 4.5eV at room temperature, and deliver those photons via fiber optic to any specified location on the surface of a detector operating at cryogenic temperatures. This new system will allow for robust calibration of any photon-sensitive detector, including supercondcting devices. The system can be used efficiently to explore the physics of target materials, quantify the position sensitivity of different sensor designs, measure phonon transport, and study the effects of quasiparticle poisoning on detector operation. We describe the design of this pulsed calibration method and present first results obtained with a second-generation system operated at room temperature and sub-Kelvin temperatures.

physics.ins-det

The DAMIC-M Low Background Chamber

The DArk Matter In CCDs at Modane (DAMIC-M) experiment is designed to search for light dark matter (m$_{\chi}$<10\,GeV/c$^2$) at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-M will use skipper charge-coupled devices (CCDs) as a kg-scale active detector target. Its single-electron resolution will enable eV-scale energy thresholds and thus world-leading sensitivity to a range of hidden sector dark matter candidates. A DAMIC-M prototype, the Low Background Chamber (LBC), has been taking data at LSM since 2022. The LBC provides a low-background environment, which has been used to characterize skipper CCDs, study dark current, and measure radiopurity of materials planned for DAMIC-M. It also allows testing of various subsystems like readout electronics, data acquisition software, and slow control. This paper describes the technical design and performance of the LBC.

physics.ins-det

First demonstration of a TES based cryogenic Li$_2$MoO$_4$detector for neutrinoless double beta decay search

Cryogenic calorimetric experiments to search for neutrinoless double-beta decay ($0\nu\beta\beta$) are highly competitive, scalable and versatile in isotope. The largest planned detector array, CUPID, is comprised of about 1500 individual Li$_2^{100}$MoO$_{4}$ detector modules with a further scale up envisioned for a follow up experiment (CUPID-1T). In this article, we present a novel detector concept targeting this second stage with a low impedance TES based readout for the Li$_2$MoO$_{4}$ absorber that is easily mass-produced and lends itself to a multiplexed readout. We present the detector design and results from a first prototype detector operated at the NEXUS shallow underground facility at Fermilab. The detector is a 2-cm-side cube with 21$\,$g mass that is strongly thermally coupled to its readout chip to allow rise-times of $\sim$0.5$\,$ms. This design is more than one order of magnitude faster than present NTD based detectors and is hence expected to effectively mitigate backgrounds generated through the pile-up of two independent two neutrino decay events coinciding close in time. Together with a baseline resolution of 1.95$\,$keV (FWHM) these performance parameters extrapolate to a background index from pile-up as low as $5\cdot 10^{-6}\,$counts/keV/kg/yr in CUPID size crystals. The detector was calibrated up to the MeV region showing sufficient dynamic range for $0\nu\beta\beta$ searches. In combination with a SuperCDMS HVeV detector this setup also allowed us to perform a precision measurement of the scintillation time constants of Li$_2$MoO$_{4}$. The crystal showed a significant fast scintillation emission with O(10$\,\mu$s) time-scale, more than an order below the detector response of presently considered light detectors suggesting the possibility of further progress in pile-up rejection through better light detectors in the future.

hep-ex

First Measurement of Correlated Charge Noise in Superconducting Qubits at an Underground Facility

We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth's surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4$\pi$ coverage of a movable lead shield, this facility enables quantifiable control over the flux of ionizing radiation on the qubit device. Long-time-series charge tomography measurements on these weakly charge-sensitive qubits capture discontinuous jumps in the induced charge on the qubit islands, corresponding to the interaction of ionizing radiation with the qubit substrate. The rate of these charge jumps scales with the flux of ionizing radiation on the qubit package, as characterized by a series of independent measurements on another energy-resolving detector operating simultaneously in the same cryostat with the qubits. Using lead shielding, we achieve a minimum charge jump rate of 0.19$^{+0.04}_{-0.03}$ mHz, almost an order of magnitude lower than that measured in surface tests, but a factor of roughly eight higher than expected based on reduction of ambient gammas alone. We operate four qubits for over 22 consecutive hours with zero correlated charge jumps at length scales above three millimeters.

quant-ph

Cryogenic optical beam steering for superconducting device calibration

We have developed a calibration system based on a micro-electromechanical systems (MEMS) mirror that is capable of delivering an optical beam over a wavelength range of 180 -- 2000 nm (0.62 -- 6.89 eV) in a sub-Kelvin environment. This portable, integrated system can steer the beam over a $\sim$3 cm $\times$ 3 cm area on the surface of any sensor with a precision of $\sim$100 $\mu$m, enabling characterization of device response as a function of position. This fills a critical need in the landscape of calibration tools for sub-Kelvin devices, including those used for dark matter detection and quantum computing. These communities have a shared goal of understanding the impact of ionizing radiation on device performance, which can be pursued with our system. This paper describes the design of the first-generation calibration system and the results from successfully testing its performance at room temperature and 20 mK.

quant-ph

Estimating the Energy Threshold of Phonon-mediated Superconducting Qubit Detectors Operated in an Energy-Relaxation Sensing Scheme

In recent years, the lack of a conclusive detection of WIMP dark matter at the 10 GeV/c$^{2}$ mass scale and above has encouraged development of low-threshold detector technology aimed at probing lighter dark matter candidates. Detectors based on Cooper-pair-breaking sensors have emerged as a promising avenue for this detection due to the low (meV-scale) energy required for breaking a Cooper pair in most superconductors. Among them, devices based on superconducting qubits are interesting candidates for sensing due to their observed sensitivity to broken Cooper pairs. We have developed an end-to-end G4CMP-based simulation framework and have used it to evaluate performance metrics of qubit-based devices operating in a gate-based "energy relaxation" readout scheme, akin to those used in recent studies of qubit sensitivity to ionizing radiation. We find that for this readout scheme, the qubit acts as a phonon sensor with an energy threshold ranging down to $\simeq$0.4 eV for near-term performance parameters.

physics.ins-det

Search for Daily Modulation of MeV Dark Matter Signals with DAMIC-M

Dark Matter (DM) particles with sufficiently large cross sections may scatter as they travel through Earth's bulk. The corresponding changes in the DM flux give rise to a characteristic daily modulation signal in detectors sensitive to DM-electron interactions. Here, we report results obtained from the first underground operation of the DAMIC-M prototype detector searching for such a signal from DM with MeV-scale mass. A model-independent analysis finds no modulation in the rate of 1$e^-$ events with sidereal period, where a DM signal would appear. We then use these data to place exclusion limits on DM in the mass range [0.53, 2.7] MeV/c$^2$ interacting with electrons via a dark photon mediator. Taking advantage of the time-dependent signal we improve by $\sim$2 orders of magnitude on our previous limit obtained from the total rate of 1$e^-$ events, using the same data set. This daily modulation search represents the current strongest limit on DM-electron scattering via ultralight mediators for DM masses around 1 MeV/c$^2$.

hep-ex

Confirmation of the spectral excess in DAMIC at SNOLAB with skipper CCDs

We present results from a 3.25 kg-day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. We address the dominant systematic uncertainty of the previous analysis through a depth fiducialization designed to reject surface backgrounds on the CCDs. The measured bulk ionization spectrum confirms the presence of an excess population of low-energy events in the CCD target with characteristic rate of ${\sim}7$ events per kg-day and electron-equivalent energies of ${\sim}80~$eV, whose origin remains unknown.

astro-ph.CO

First Constraints from DAMIC-M on Sub-GeV Dark-Matter Particles Interacting with Electrons

We report constraints on sub-GeV dark matter particles interacting with electrons from the first underground operation of DAMIC-M detectors. The search is performed with an integrated exposure of 85.23 g days, and exploits the subelectron charge resolution and low level of dark current of DAMIC-M charge-coupled devices (CCDs). Dark-matter-induced ionization signals above the detector dark current are searched for in CCD pixels with charge up to 7e$^-$. With this dataset we place limits on dark matter particles of mass between 0.53 and 1000 MeV/$c^2$, excluding unexplored regions of parameter space in the mass ranges [1.6,1000] MeV/$c^2$ and [1.5,15.1] MeV/$c^2$ for ultralight and heavy mediator interactions, respectively.

hep-ex

Search for inelastic dark matter-nucleus scattering with the PICO-60 CF$_{3}$I and C$_{3}$F$_{8}$ bubble chambers

PICO bubble chambers have exceptional sensitivity to inelastic dark matter-nucleus interactions due to a combination of their extended nuclear recoil energy detection window from a few keV to $O$(100 keV) or more and the use of iodine as a heavy target. Inelastic dark matter-nucleus scattering is interesting for studying the properties of dark matter, where many theoretical scenarios have been developed. This study reports the results of a search for dark matter inelastic scattering with the PICO-60 bubble chambers. The analysis reported here comprises physics runs from PICO-60 bubble chambers using CF$_{3}$I and C$_{3}$F$_{8}$. The CF$_{3}$I run consisted of 36.8 kg of CF$_{3}$I reaching an exposure of 3415 kg-day operating at thermodynamic thresholds between 7 and 20 keV. The C$_{3}$F$_{8}$ runs consisted of 52 kg of C$_{3}$F$_{8}$ reaching exposures of 1404 kg-day and 1167 kg-day running at thermodynamic thresholds of 2.45 keV and 3.29 keV, respectively. The analysis disfavors various scenarios, in a wide region of parameter space, that provide a feasible explanation of the signal observed by DAMA, assuming an inelastic interaction, considering that the PICO CF$_{3}$I bubble chamber used iodine as the target material.

astro-ph.CO

The DAMIC-M Experiment: Status and First Results

The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV-scale. DAMIC-M will advance by several orders of magnitude the exploration of the dark matter particle hypothesis, in particular of candidates pertaining to the so-called "hidden sector." A prototype, the Low Background Chamber (LBC), with 20g of low background Skipper CCDs, has been recently installed at Laboratoire Souterrain de Modane and is currently taking data. We will report the status of the DAMIC-M experiment and first results obtained with LBC commissioning data.

hep-ex

Precision measurement of Compton scattering in silicon with a skipper CCD for dark matter detection

Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $\gamma$-rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a precision measurement of Compton scattering on silicon atomic shell electrons down to 23$\,$eV. A skipper charge-coupled device (CCD) with single-electron resolution, developed for the DAMIC-M experiment, was exposed to a $^{241}$Am $\gamma$-ray source over several months. Features associated with the silicon K, L$_{1}$, and L$_{2,3}$-shells are clearly identified, and scattering on valence electrons is detected for the first time below 100$\,$eV. We find that the relativistic impulse approximation for Compton scattering, which is implemented in Monte Carlo simulations commonly used by direct detection experiments, does not reproduce the measured spectrum below 0.5$\,$keV. The data are in better agreement with $ab$ $initio$ calculations originally developed for X-ray absorption spectroscopy.

physics.ins-det

Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C$_3$F$_8$ dark matter detectors

The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct neutron spectra at various thermodynamic thresholds ranging from 2.1 keV to 3.9 keV. Instead of assuming any particular functional forms for the nuclear recoil efficiency, a generalized piecewise linear model is proposed with systematic errors included as nuisance parameters to minimize model-introduced uncertainties. A Markov-Chain Monte-Carlo (MCMC) routine is applied to sample the nuclear recoil efficiency for fluorine and carbon at 2.45 keV and 3.29 keV thermodynamic thresholds simultaneously. The nucleation efficiency for fluorine was found to be $\geq 50\, \%$ for nuclear recoils of 3.3 keV (3.7 keV) at a thermodynamic Seitz threshold of 2.45 keV (3.29 keV), and for carbon the efficiency was found to be $\geq 50\, \%$ for recoils of 10.6 keV (11.1 keV) at a threshold of 2.45 keV (3.29 keV). Simulated data sets are used to calculate a p-value for the fit, confirming that the model used is compatible with the data. The fit paradigm is also assessed for potential systematic biases, which although small, are corrected for. Additional steps are performed to calculate the expected interaction rates of WIMPs in the PICO-60 detector, a requirement for calculating WIMP exclusion limits.

physics.ins-det