arXiv ScienceSearch

arXiv subjects

Christopher Walker

Publications and source records attributed to Christopher Walker.

At least 19 recordsLinked to original sources

Diver-Robot Communication Dataset for Underwater Hand Gesture Recognition

In this paper, we present a dataset of diving gesture images used for human-robot interaction underwater. By offering this open access dataset, the paper aims at investigating the potential of using visual detection of diving gestures from an autonomous underwater vehicle (AUV) as a form of communication with a human diver. In addition to the image recording, the same dataset was recorded using a smart gesture recognition glove. The glove uses elastomer sensors and on-board processing to determine the selected gesture and transmit the command associated with the gesture to the AUV via acoustics. Although this method can be used under different visibility conditions and even without line of sight, it introduces a communication delay required for the acoustic transmission of the gesture command. To compare efficiency, the glove was equipped with visual markers proposed in a gesture-based language called CADDIAN and recorded with an underwater camera in parallel to the glove's onboard recognition process. The dataset contains over 30,000 underwater frames of nearly 900 individual gestures annotated in corresponding snippet folders. The dataset was recorded in a balanced ratio with five different divers in sea and five different divers in pool conditions, with gestures recorded at 1, 2 and 3 metres from the camera. The glove gesture recognition statistics are reported in terms of average diver reaction time, average time taken to perform a gesture, recognition success rate, transmission times and more. The dataset presented should provide a good baseline for comparing the performance of state of the art visual diving gesture recognition techniques under different visibility conditions.

eess.IV

Star and Planet Formation with the Single Aperture Large Telescope for Universe Studies (SALTUS) Space Observatory

The Single Aperture Large Telescope for Universe Studies (SALTUS) is a far-infrared space mission concept with unprecedented spatial and spectral resolution. Saltus consists of a 14-m inflatable primary, providing 16 times the sensitivity and 4 times the angular resolution of Herschel, and two cryogenic detectors spanning a wavelength range of 34-660 microns and spectral resolving power of 300 - 1e7. Spectroscopic observations in the far-infrared offer many unique windows into the processes of star and planet formation. These include observations of low energy water transitions, the H2 mass tracer HD, many CHONS constraining molecules such as NH3 and H2S, and emission lines from the phonon modes of molecular ices. Observing these species will allow us to build a statistical sample of protoplanetary disk masses, characterize the water snowline, identify Kuiper Belt like debris rings around other stars, and trace the evolution CHONS from prestellar cores, through to protoplanetary disks and debris disks. This paper details details several key star and planet formation science goals achievable with SALTUS.

astro-ph.IM

14-m aperture deployable off-axis far-IR space telescope design for SALTUS observatory

The Single Aperture Large Telescope for Universe Studies (SALTUS) is a deployable space telescope designed to provide the astrophysics community with an extremely large far-infrared (far-IR) space observatory to explore our cosmic origins. The SALTUS observatory can observe thousands of faint astrophysical targets, including the first galaxies, protoplanetary disks in various evolutionary states, and a wide variety of solar system objects. The SALTUS design architecture utilizes radiatively cooled, 14-m diameter unobscured aperture, and cryogenic instruments to enable both high spectral and spatial resolution at unprecedented sensitivity over a wavelength range largely unavailable to any existing ground or space observatories. The unique SALTUS optical design, utilizing a large inflatable off-axis primary mirror, provides superb sensitivity, angular resolution, and imaging performance at far-IR wavelengths over a wide +/-0.02 x 0.02 degree Field of View. SALTUS design, with its highly compact form factor, allows it to be readily stowed in available launch fairings and subsequently deployed in orbit.

astro-ph.IM

Design, Implementation, and Performance of the Primary Reflector for SALTUS

The Single Aperture Large Telescope for Universe Studies (SALTUS) is a mission concept for a far-infrared observatory developed under the recent Astrophysics Probe Explorer opportunity from NASA. The enabling element of the program is a 14 m diameter inflatable primary mirror, M1. Due to its importance to SALTUS and potentially other space observatories, this paper focuses entirely on M1. We present a historical overview of inflatable systems, illustrating that M1 is the logical next step in the evolution of such systems. The process of design and manufacture is addressed. We examine how M1 performs in its environment in terms of operating temperature, interaction with the solar wind, and shape change due to non-penetrating particles. We investigate the longevity of the inflatant in detail and show it meets mission lifetime requirements with ample margin and discuss the development and testing to realize the flight M1.

astro-ph.IM

SALTUS Probe Class Space Mission: Observatory Architecture and Mission Design

We describe the space observatory architecture and mission design of the SALTUS mission, a NASA Astrophysics Probe Explorer concept. SALTUS will address key far-infrared science using a 14-m diameter <45 K primary reflector (M1) and will provide unprecedented levels of spectral sensitivity for planet, solar system, and galactic evolution studies, and cosmic origins. Drawing from Northrop Grumman's extensive NASA mission heritage, the observatory flight system is based on the LEOStar-3 spacecraft platform to carry the SALTUS Payload. The Payload is comprised of the inflation control system (ICS), Sunshield Module (SM), Cold Corrector Module (CCM), Warm Instrument Electronics Module, and Primary Reflector Module (PRM). The 14-m M1 is an off-axis inflatable membrane radiatively cooled by a two-layer sunshield (~1,000 m2 per layer). The CCM corrects for residual aberration from M1 and delivers a focused beam to two instruments - High Resolution Receiver (HiRX) and SAFARI-Lite. The CCM and PRM reside atop a truss-based composite deck which also provides a platform for the attitude control system. The 5-year mission lifetime is driven by a two-consumable architecture: the propellant system and the ICS. The Core Interface Module (CIM), a multi-faceted composite truss structure, provides a load path with high stiffness, mechanical attachment, and thermal separation between the Payload and spacecraft. The SM attaches outside the CIM with its aft end integrating directly to the bus. The spacecraft maintains an attitude off M1's boresight with respect to the Sun line to facilitate the <45 K thermal environment. SALTUS will reside in a Sun-Earth halo L2 orbit with a maximum Earth slant range of 1.8 million km thereby reducing orbit transfer delta-v. The instantaneous field of regard provides two continuous 20-deg viewing zones around the ecliptic poles resulting in full sky coverage in six months.

astro-ph.IM

The Use of Quantitative Metrics and Machine Learning to Predict Radiologist Interpretations of MRI Image Quality and Artifacts

A dataset of 3D-GRE and 3D-TSE brain 3T post contrast T1-weighted images as part of a quality improvement project were collected and shown to five neuro-radiologists who evaluated each sequence for both image quality and imaging artifacts. The same scans were processed using the MRQy tool for objective, quantitative image quality metrics. Using the combined radiologist and quantitative metrics dataset, a decision tree classifier with a bagging ensemble approach was trained to predict radiologist assessment using the quantitative metrics. A machine learning model was developed for the following three tasks: (1) determine the best model / performance for each MRI sequence and evaluation metric, (2) determine the best model / performance across all MRI sequences for each evaluation metric, and (3) determine the best general model / performance across all MRI sequences and evaluations. Model performance for imaging artifact was slightly higher than image quality, for example, the final generalized model AUROC for image quality was 0.77 (0.41 - 0.84, 95% CI) while imaging artifact was 0.78 (0.60 - 0.93, 95% CI). Further, it was noted that the generalized model performed slightly better than the individual models (AUROC 0.69 for 3D-GRE image quality, for example), indicating the value in comprehensive training data for these applications. These models could be deployed in the clinic as automatic checks for real-time image acquisition to prevent patient re-scanning requiring another appointment after retrospective radiologist analysis or improve reader confidence in the study. Further work needs to be done to validate the model described here on an external dataset. The results presented here suggest that MRQy could be used as a foundation for quantitative metrics as a surrogate for radiologist assessment.

physics.med-ph

4x2 Hot electron bolometer mixer arrays for detection at 1.46, 1.9 and 4.7 THz for a balloon borne terahertz observatory

We have demonstrated three 4x2 hot electron bolometer (HEB) mixer arrays for operation at local oscillator (LO) frequencies of 1.46, 1.9 and 4.7 THz, respectively. They consist of spiral antenna coupled NbN HEB mixers combined with elliptical lenses. These are to date the highest pixel count arrays using a quasi-optical coupling scheme at supra-THz frequencies. At 1.4 THz, we measured an average double sideband mixer noise temperature of 330 K, a mixer conversion loss of 5.7 dB, and an optimum LO power of 210 nW. The array at 1.9 THz has an average mixer noise temperature of 420K, a conversion loss of 6.9 dB, and an optimum LO power of 190 nW. For the array at 4.7 THz, we obtained an average mixer noise temperature of 700 K, a conversion loss of 9.7 dB, and an optimum LO power of 240 nW. We found the arrays to be uniform regarding the mixer noise temperature with a standard deviation of 3-4%, the conversion loss with a standard deviation of 7-10%, and optimum LO power with a standard deviation of 5-6%. The noise bandwidth was also measured, being 3.5 GHz for the three arrays. These performances are comparable to previously reported values in the literature for single pixels and also other detector arrays. Our arrays meet the requirements of the Galactic/Extra-Galactic ULDB Spectroscopic Terahertz Observatory (GUSTO), a NASA balloon borne observatory, and are therefore scheduled to fly as part of the payload, which is expected to be launched in December 2023.

physics.ins-det

Protoplanetary Disk Science with the Orbiting Astronomical Satellite Investigating Stellar Systems (OASIS) Observatory

The Orbiting Astronomical Satellite for Investigating Stellar Systems (OASIS) is a NASA Astrophysics MIDEX-class mission concept, with the stated goal of following water from galaxies, through protostellar systems, to Earth's oceans. This paper details the protoplanetary disk science achievable with OASIS. OASIS's suite of heterodyne receivers allow for simultaneous, high spectral resolution observations of water emission lines spanning a large range of physical conditions within protoplanetary disks. These observations will allow us to map the spatial distribution of water vapor in disks across evolutionary stages and assess the importance of water, particularly the location of the midplane water snowline, to planet formation. OASIS will also detect the H2 isotopologue HD in 100+ disks, allowing for the most accurate determination of total protoplanetary disk gas mass to date. When combined with the contemporaneous water observations, the HD detection will also allow us to trace the evolution of water vapor across evolutionary stages. These observations will enable OASIS to characterize the time development of the water distribution and the role water plays in the process of planetary system formation.

astro-ph.EP

A tabletop x-ray tomography instrument for nanometer-scale imaging: demonstration of the 1,000-element transition-edge sensor subarray

We report on the 1,000-element transition-edge sensor (TES) x-ray spectrometer implementation of the TOMographic Circuit Analysis Tool (TOMCAT). TOMCAT combines a high spatial resolution scanning electron microscope (SEM) with a highly efficient and pixelated TES spectrometer to reconstruct three-dimensional maps of nanoscale integrated circuits (ICs). A 240-pixel prototype spectrometer was recently used to reconstruct ICs at the 130 nm technology node, but to increase imaging speed to more practical levels, the detector efficiency needs to be improved. For this reason, we are building a spectrometer that will eventually contain 3,000 TES microcalorimeters read out with microwave superconducting quantum interference device (SQUID) multiplexing, and we currently have commissioned a 1,000 TES subarray. This still represents a significant improvement from the 240-pixel system and allows us to begin characterizing the full spectrometer performance. Of the 992 maximimum available readout channels, we have yielded 818 devices, representing the largest number of TES x-ray microcalorimeters simultaneously read out to date. These microcalorimeters have been optimized for pulse speed rather than purely energy resolution, and we measure a FWHM energy resolution of 14 eV at the 8.0 keV Cu K$\alpha$ line.

physics.ins-det

Nanoscale Three-Dimensional Imaging of Integrated Circuits using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but is difficult to implement due to competing requirements on X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while changing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot in a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with high signal-to-noise. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enable nanoscale, element-specific X-ray imaging in a compact footprint. The proof-of-concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in 6 layers of a Cu-SiO2 integrated circuit, and a path towards finer resolution and enhanced imaging capabilities is discussed.

physics.ins-det

Design of a 3000-pixel transition-edge sensor x-ray spectrometer for microcircuit tomography

Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabrication. This can be important for process development, defect analysis, and detection of unexpected structures in externally sourced chips, among other applications. Here, we report on a non-destructive, tabletop approach that addresses this imaging problem through x-ray tomography, which we uniquely realize with an instrument that combines a scanning electron microscope (SEM) with a transition-edge sensor (TES) x-ray spectrometer. Our approach uses the highly focused SEM electron beam to generate a small x-ray generation region in a carefully designed target layer that is placed over the sample being tested. With the high collection efficiency and resolving power of a TES spectrometer, we can isolate x-rays generated in the target from background and trace their paths through regions of interest in the sample layers, providing information about the various materials along the x-ray paths through their attenuation functions. We have recently demonstrated our approach using a 240 Mo/Cu bilayer TES prototype instrument on a simplified test sample containing features with sizes of $\sim$1 $\mu$m. Currently, we are designing and building a 3000 Mo/Au bilayer TES spectrometer upgrade, which is expected to improve the imaging speed by factor of up to 60 through a combination of increased detector number and detector speed.

physics.ins-det

A Roadmap For Scientific Ballooning 2020-2030

From 2018 to 2020, the Scientific Balloon Roadmap Program Analysis Group (Balloon Roadmap PAG) served as an community-based, interdisciplinary forum for soliciting and coordinating community analysis and input in support of the NASA Scientific Balloon Program. The Balloon Roadmap PAG was tasked with articulating and prioritizing the key science drivers and needed capabilities of the Balloon Program for the next decade. Additionally, the Balloon Roadmap PAG was asked to evaluate the potential for achieving science goals and maturing technologies of the Science Mission Directorate, evaluate the Balloon Program goals towards community outreach, and asses commercial balloon launch opportunities. The culmination of this work has been a written report submitted to the NASA Astrophysics Division Director.

astro-ph.IM

Mutual-Information Based Optimal Experimental Design for Hyperpolarized $^{13}$C-Pyruvate MRI

A key parameter of interest recovered from hyperpolarized (HP) MRI measurements is the apparent pyruvate-to-lactate exchange rate, $k_{PL}$, for measuring tumor metabolism. This manuscript presents an information-theory-based optimal experimental design (OED) approach that minimizes the uncertainty in the rate parameter, $k_{PL}$, recovered from HP-MRI measurements. Mutual information (MI) is employed to measure the information content of the HP measurements with respect to the first-order exchange kinetics of the pyruvate conversion to lactate. Flip angles of the pulse sequence acquisition are optimized with respect to the mutual information. Further, a spatially varying model (high-fidelity) based on the Block-Torrey equations is proposed and utilized as a control. A time-varying flip angle scheme leads to a higher parameter optimization that can further improve the quantitative value of mutual information over a constant flip angle scheme. However, the constant flip angle scheme leads to the best accuracy and precision when considering inference from noise-corrupted data. For the particular MRI data examined here, pyruvate and lactate flip angles of 35 and 28 degrees, respectively, were the best choice in terms of accuracy and precision of the parameter recovery. Moreover, the recovery of rate parameter $k_{PL}$ from the data generated from the high-fidelity model highlights the influence of diffusion and strength of vascular source on the recovered rate parameter. Since the existing pharmacokinetic models for HP-MRI do not account for spatial variation, the optimized design parameters may not be fully optimal in a more general 3D setting.

cs.IT

Applications of Machine Learning Algorithms In Processing Terahertz Spectroscopic Data

We present the data reduction software and the distribution of Level 1 and Level 2 products of the Stratospheric Terahertz Observatory 2 (STO2). STO2, a balloon-borne Terahertz telescope, surveyed star-forming regions and the Galactic plane and produced approximately 300,000 spectra. The data are largely similar to spectra typically produced by single-dish radio telescopes. However, a fraction of the data contained rapidly varying fringe/baseline features and drift noise, which could not be adequately corrected using conventional data reduction software. To process the entire science data of the STO2 mission, we have adopted a new method to find proper off-source spectra to reduce large-amplitude fringes and new algorithms including Asymmetric Least Square (ALS), Independent Component Analysis (ICA), and Density-based spatial clustering of applications with noise (DBSCAN). The STO2 data reduction software efficiently reduced the amplitude of fringes from a few hundred to 10 K and resulted in baselines of amplitude down to a few K. The Level 1 products typically have the noise of a few K in [CII] spectra and ~1 K in [NII] spectra. Using a regridding algorithm, we made spectral maps of star-forming regions and the Galactic plane survey using an algorithm employing a Bessel-Gaussian kernel. Level 1 and 2 products are available to the astronomical community through the STO2 data server and the DataVerse. The software is also accessible to the public through Github. The detailed addresses are given in Section 4 of the paper on data distribution.

astro-ph.IM

Transparent Metasurfaces Counteracting Fogging by Harnessing Sunlight

Surface fogging is a common phenomenon that can have significant and detrimental effects on surface transparency and visibility. It affects the performance in a wide range of applications including windows, windshields, electronic displays, cameras, mirrors, and eyewear. A host of ongoing research is aimed at combating this problem by understanding and developing stable and effective anti-fogging coatings that are capable of handling a wide range of environmental challenges "passively" without consumption of electrical energy. Here we introduce an alternative approach employing sunlight to go beyond state-of-the-art techniques---such as superhydrophilic and superhydrophobic coatings---by rationally engineering solar absorbing metasurfaces that maintain transparency, while upon illumination, induce localized heating to significantly delay the onset of surface fogging or decrease defogging time. For the same environmental conditions, we demonstrate that our metasurfaces are able to reduce defogging time by up to four-fold and under supersaturated conditions inhibit the nucleation of condensate outperforming conventional state-of-the-art approaches in terms of visibility retention. Our research illustrates a durable and environmentally sustainable approach to passive anti-fogging and defogging for transparent surfaces. This work opens up the opportunity for large-scale manufacturing that can be applied to a range of materials, including polymers and other flexible substrates.

physics.app-ph

Desublimation Frosting on Nanoengineered Surfaces

Ice nucleation from vapor presents a variety of challenges across a wide range of industries and applications including refrigeration, transportation, and energy generation. However, a rational comprehensive approach to fabricating intrinsically icephobic surfaces for frost formation-both from water condensation (followed by freezing) and in particular from desublimation (direct growth of ice crystals from vapor)-remains elusive. Here, guided by nucleation physics, we investigate the effect of material composition and surface texturing (atomically smooth to nanorough) on the nucleation and growth mechanism of frost for a range of conditions within the sublimation domain (0 C to -55C; partial water vapor pressures 6 to 0.02 mbar). Surprisingly, we observe that on silicon at very cold temperatures-below the homogeneous ice solidification nucleation limit (< -46 C)-desublimation does not become the favorable pathway to frosting. Furthermore we show that surface nanoroughness makes frost formation on silicon more probable. We experimentally demonstrate at temperatures between -48 C and -55 C that nanotexture with radii of curvature within one order of magnitude of the critical radius of nucleation favors frost growth, facilitated by capillary condensation, consistent with Kelvin's Equation. Our findings show that such nanoscale surface morphology imposed by design to impart desired functionalities-such as superhydrophobicity-or from defects, can be highly detrimental for frost icephobicity at low temperatures and water vapor partial pressures (< 0.05 mbar). Our work contributes to the fundamental understanding of heterogeneous phase transitions well within the equilibrium sublimation domain and has implications for applications such as travel, power generation, and refrigeration.

physics.app-ph

Detergency and its implications for oil emulsion sieving and separation

Separating petroleum hydrocarbons from water is an important problem to address in order to mitigate the disastrous effects of hydrocarbons on aquatic ecosystems. A rational approach to address the problem of marine oil water separation is to disperse the oil with the aid of surfactants in order to minimize the formation of large slicks at the water surface and to maximize the oil-water interfacial area. Here we investigate the fundamental wetting and transport behavior of such surfactant-stabilized droplets and the flow conditions necessary to perform sieving and separation of these stabilized emulsions. We show that, for water soluble surfactants, such droplets are completely repelled by a range of materials (intrinsically underwater superoleophobic) due to the detergency effect; therefore, there is no need for surface micro/nanotexturing or chemical treatment to repel the oil and prevent fouling of the filter. We then simulate and experimentally investigate the effect of emulsion flow rate on the transport and impact behavior of such droplets on rigid meshes to identify the minimum pore opening (w) necessary to filter a droplet with a given diameter (d) in order to minimize the pressure drop across the mesh and therefore maximize the filtering efficiency, which is strongly dependent on w. We define a range of flow conditions and droplet sizes where minimum droplet deformation is to be expected and therefore find that the condition of is sufficient for efficient separation. With this new understanding, we demonstrate the use of a commercially available filter--without any additional surface engineering or functionalization--to separate oil droplets from a surfactant stabilized emulsion with a flux of 11,000 L m$^{-2}$ hr$^{-1}$ bar$^{-1}$. We believe these findings can inform the design of future oil separation materials.

cond-mat.soft

A Categorification of Hall Algebras

In recent years, there has been great interest in the study of categorification, specifically as it applies to the theory of quantum groups. In this thesis, we would like to provide a new approach to this problem by looking at Hall algebras. It is know, due to Ringel, that a Hall algebra is isomorphic to a certain quantum group. It is our goal to describe a categorification of Hall algebras as a way of doing so for their related quantum groups. To do this, we will take the following steps. First, we describe a new perspective on the structure theory of Hall algebras. This view solves, in a unique way, the classic problem of the multiplication and comultiplication not being compatible. Our solution is to switch to a different underlying category $\Vect^K$ of vector spaces graded by a group $K$ called the Grothendieck group. We equip this category with a nontrivial braiding which depends on the $K$-grading. With this braiding and a given antipode, we find that the Hall algebra does become a Hopf algebra object in $\Vect^K$. Second, we will describe a categorification process, call `groupoidification', which replaces vector spaces with groupoids and linear operators with `spans' of groupoids. We will use this process to construct a braided monoidal bicategory which categorifies $\Vect^K$ via the groupoidification program. Specifically, graded vector spaces will be replaced with groupoids `over' a fixed groupoid related to the Grothendieck group $K$. The braiding structure will come from an interesting groupoid $\EXT(M,N)$ which will behave like the Euler characteristic for the Grothendieck group $K$. We will finish with a description of our plan to, in future work, apply the same concept to the structure maps of the Hall algebra, which will eventually give us a Hopf 2-algebra object in our braided monoidal bicategory.

math.CT