arXiv ScienceSearch

arXiv subjects

Christopher Leitz

Publications and source records attributed to Christopher Leitz.

17 recordsLinked to original sources

Fast, low noise, megapixel detector and readout systems for future X-ray astronomy missions

Next-generation strategic X-ray astronomy missions will require the simultaneous achievement of high angular resolution, large effective collecting area, and wide-field imaging with large-format focal plane detectors. Realizing the associated science objectives--ranging from precision measurements of bright point sources to the detection and characterization of faint diffuse emission-places stringent and, in some cases, competing requirements on detector performance. In particular, high frame rates are necessary to mitigate photon pile-up in observations of bright sources and to reduce contamination from particle-induced background in measurements of low surface brightness structures. At the same time, these instruments must preserve excellent soft X-ray response, which places tight constraints on read noise and on the fidelity of event characterization. State-of-the-art X-ray charge-coupled devices (CCDs) approach many of the key performance metrics required for these missions, but readout speed remains a primary limitation. Addressing this gap requires readout architectures that scale to high channel count, sustain high pixel throughput, and preserve the low-noise characteristics needed for soft X-ray sensitivity.

astro-ph.IM

High-speed, low-noise, multi-megapixel CCDs for next generation X-ray observatories

Next generation X-ray observatories require fast, low-noise, low-power, multi-megapixel imaging spectrometers. To meet these demands, the X-ray Astronomy and Observational Cosmology (XOC) Group at Stanford, in partnership with the MIT Kavli Institute and MIT Lincoln Laboratory (MIT-LL), is developing multi-channel X-ray charge-coupled devices (CCDs) and fast readout architectures. We report the energy resolution and noise performance achieved with a full-scale (1440x1440-pixel), 16-channel, front-illuminated MIT-LL CCD detector developed for the Advanced X-ray Imaging Satellite (AXIS) concept, the CCID-100, read out using two Multi-Channel Readout Chip (MCRC) V1 application-specific integrated circuit (ASIC) chips in the new Stanford CCID-100 test setup. We describe an automated method for bias optimization on each CCD channel, and integrated debugging features of the front-end ASIC and readout system. The demonstrated performance confirms that these systems can meet the speed and noise requirements of future strategic X-ray missions.

astro-ph.IM

Advancing X-Ray Camera Front-End Electronics Architecture through the AXIS-TAP Technology Platform

Advancing time-domain soft X-ray astronomy demands focal plane readout electronics capable of high-speed digitization with low noise while maintaining spectral fidelity across multiple detector channels. The Advanced X-ray Imaging Satellite (AXIS), a NASA Probe-class mission concept, provided the driving requirements and heritage for developing a generalized high-speed (>=5 fps) camera Front-End Electronics (FEE) architecture applicable to future soft X-ray missions. The FEE architecture defines a modular, dual-box redundant configuration to operate a focal plane of four 16-channel CCDs, with functional partitioning for power distribution, thermal management, mechanism control, and image data acquisition and transmission to the spacecraft. To validate the core signal chain architecture, particularly the analog-to-digital conversion, FPGA-based processing, and Ethernet data transmission, a dedicated technology demonstrator, AXIS-TAP (ADC Testing and Acquisition Platform), has been designed and is currently in fabrication. AXIS-TAP employs commercial equivalents of radiation-tolerant components (FPGA, ADCs, Ethernet PHY) and interfaces directly with the STA Archon benchtop readout system, enabling simultaneous image acquisition from both systems to validate that the flight-like architecture achieves equivalent or superior noise performance. This paper presents the FEE architectural framework, the AXIS-TAP demonstrator design, and the design principles that enable scalability to future soft X-ray missions with similar detector requirements. Performance validation results will be reported upon completion of AXIS-TAP system integration and testing.

astro-ph.IM

Output-Stage Design Optimization for High-Sensitivity SiSeRO CCDs and SiSeRO Active Pixel Sensors

The Single electron Sensitive Read Out (SiSeRO) technology is a new device class designed to support the needs of future X-ray and optical astronomical telescopes that will require fast, low-noise, megapixel spectro-imagers. Developed at MIT Lincoln Laboratory, in collaboration with Stanford University and MIT, the first generation SiSeRO-CCD (charge-coupled device) prototypes achieved a charge/current conversion gain of 700$-$800 pA per electron, an equivalent noise charge (ENC) of around 3.5 electrons root mean square (RMS), and a full width half maximum (FWHM) energy resolution of approximately 130 eV at 5.9 keV at a readout speed of 625 kpix/s. Utilizing Repetitive Non-Destructive Readout (RNDR), these same devices also demonstrated sub-electron noise performance (ENC$<$0.5 electrons RMS) at a readout speed of 10 kpix/s. We present the results of device simulations for next-generation SiSeRO CCD output stages that optimize the sensing transistor and its internal gate geometry to enhance noise and speed performance. Further, the goal is to develop a SiSeRO active pixel sensor (APS) that combines the proven X-ray performance of CCDs with the architectural advantages of an APS. Enabling this requires substantial design updates, for example, incorporating two SiSeRO amplifiers side by side on each pixel and shuffling the charge between them to support RNDR. We discuss our device simulation framework and design parameter optimization in the first-generation SiSeRO devices.

astro-ph.IM

The High-Speed FPGA Readout System for the Advanced X-ray Imaging Satellite (AXIS)

The Advanced X-ray Imaging Satellite (AXIS) is a Probe-class mission concept designed to deliver arcsecond spatial resolution, high-sensitivity spectral imaging across the 0.3-10 keV band. The X-ray Astronomy and Observational Cosmology (XOC) Group at Stanford, in collaboration with the MIT Kavli Institute (MKI) and MIT Lincoln Laboratory (MIT-LL), is developing the AXIS X-ray camera, including both the detector and the front-end readout electronics required to meet the mission's demanding performance goals. The telescope's focal plane detector consists of four 1440x1440 pixel charge-coupled devices (CCDs) developed by MIT-LL, each featuring 16 parallel output channels. These outputs are amplified by a high-speed, low-power, low-noise application-specific integrated circuit (ASIC) - the Multi-Channel Readout Chip (MCRC) - developed at Stanford. Following amplification, the analog signals are digitized and processed to construct a pixel array, prior to event detection. Here, we present the field-programmable gate array (FPGA) architecture developed to enable high-speed, parallelized readout of these CCD channels. The FPGA samples 16 analog-to-digital converter (ADC) channels at 50 MHz, performs preprocessing of pixel data, which is then streamed via User Datagram Protocol (UDP) over a 1 Gb Ethernet link to the back-end system for event reconstruction. Our design demonstrates the goal readout performance for AXIS (20 frames per second) and provides a framework for future high-throughput X-ray observatories.

astro-ph.IM

RNDR noise modeling in first-generation Single electron Sensitive Readout (SiSeRO) devices

Flagship observatories require single-photon detectors with ultra-fast readout, sub-electron noise performance, and scalable large-format architectures. The X-ray Astronomy and Observational Cosmology group at Stanford, in collaboration with the MIT Kavli Institute and MIT Lincoln Laboratory, is developing readout technologies for next-generation detectors. Prototypes employing Single-electron Sensitive Readout (SiSeRO) amplifiers demonstrate excellent read noise and spectral performance using repetitive non-destructive readout (RNDR), achieving 0.5 e$^-$ noise in under 57 cycles. We have modeled noise for longer RNDR cycles, exploring probabilistic mechanisms such as thermal leakage and impact ionization. Here we present our model results, including statistical limits on dark current-like signals. Maturation of SiSeRO technology will improve detector performance at soft X-ray energies, addressing technology gaps for future X-ray and UV/visible/near-IR observatories.

astro-ph.IM

The high-speed X-ray camera on AXIS: design and performance updates

AXIS, a Probe mission concept now in a Phase A study, will provide transformative studies of high-energy astrophysical phenomena thanks to its high-resolution X-ray spectral imaging. These capabilities are enabled by improvements to the mirror design that greatly increase the X-ray throughput per unit mass; and to the detector system, which operates more than an order of magnitude faster than heritage instruments while maintaining excellent spectral performance. We present updates to the design of the AXIS High-Speed Camera, a collaborative effort by MIT, Stanford University, the Pennsylvania State University, and the Southwest Research Institute. The camera employs large-format MIT Lincoln Laboratory CCDs that feature multiple high-speed, low-noise output amplifiers and an advanced single-layer polysilicon gate structure for fast, low-power clock transfers. A first lot of prototype CCID100 CCDs has completed fabrication and will soon begin X-ray performance testing. The CCDs are paired with high-speed, low-noise ASIC readout chips designed by Stanford to provide better performance than conventional discrete solutions at a fraction of the power consumption and footprint. Complementary Front-End Electronics employ state-of-the-art digital video waveform capture and advanced signal processing to further deliver low noise at high speed. The Back-End Electronics provide high-speed identification of candidate X-ray events and transient monitoring that relays fast alerts of changing sources to the community. We highlight updates to our parallel X-ray performance test facilities at MIT and Stanford, and review the current performance of the CCD and ASIC technology from testing of prototype devices. These measurements achieve excellent spectral response at the required readout rate, demonstrating that we will meet mission requirements and enable AXIS to achieve world-class science.

astro-ph.IM

Development and testing of integrated readout electronics for next generation SiSeRO (Single electron Sensitive Read Out) devices

The first generation of Single electron Sensitive Read Out (SiSeRO) amplifiers, employed as on-chip charge detectors for charge-coupled devices (CCDs) have demonstrated excellent noise and spectral performance: a responsivity of around 800 pA per electron, an equivalent noise charge (ENC) of 3.2 electrons root mean square (RMS), and a full width half maximum (FWHM) energy resolution of 130 eV at 5.9 keV for a readout speed of 625 Kpixel/s. Repetitive Non Destructive Readout (RNDR) has also been demonstrated with these devices, achieving an improved ENC performance of 0.36 electrons RMS after 200 RNDR cycles. In order to mature this technology further, Stanford University, in collaboration with MIT Kavli Institute and MIT Lincoln Laboratory, are developing new SiSeRO detectors with improved geometries that should enable greater responsivity and improved noise performance. These include CCD devices employing arrays of SiSeRO amplifiers to optimize high speed, low noise RNDR readout and a proof-of-concept SiSeRO active pixel sensor (APS). To read out these devices, our team has developed a compact, 8-channel, fast, low noise, low power application specific integrated circuit (ASIC) denoted the Multi-Channel Readout Chip (MCRC) that includes an experimental drain current readout mode intended for SiSeRO devices. In this paper, we present results from the first tests of SiSeRO CCD devices operating with MCRC readout, and our designs for next generation SiSeRO devices.

astro-ph.IM

Focal Plane of the Arcus Probe X-Ray Spectrograph

The Arcus Probe mission concept provides high-resolution soft X-ray and UV spectroscopy to reveal feedback-driven structure and evolution throughout the universe with an agile response capability ideal for probing the physics of time-dependent phenomena. The X-ray Spectrograph (XRS) utilizes two nearly identical CCD focal planes to detect and record X-ray photons from the dispersed spectra and zero-order of the critical angle transmission gratings. In this paper we describe the Arcus focal plane instrument and the CCDs, including laboratory performance results, which meet observatory requirements.

astro-ph.IM

Curved detectors for future X-ray astrophysics missions

Future X-ray astrophysics missions will survey large areas of the sky with unparalleled sensitivity, enabled by lightweight, high-resolution optics. These optics inherently produce curved focal surfaces with radii as small as 2 m, requiring a large area detector system that closely conforms to the curved focal surface. We have embarked on a project using a curved charge-coupled device (CCD) detector technology developed at MIT Lincoln Laboratory to provide large-format, curved detectors for such missions, improving performance and simplifying design. We present the current status of this work, which aims to curve back-illuminated, large-format (5 cm x 4 cm) CCDs to 2.5-m radius and confirm X-ray performance. We detail the design of fixtures and the curving process, and present intial results on curving bare silicon samples and monitor devices and characterizing the surface geometric accuracy. The tests meet our accuracy requirement of <5 $\mu$m RMS surface non-conformance for samples of similar thickness to the functional detectors. We finally show X-ray performance measurements of planar CCDs that will serve as a baseline to evaluate the curved detectors. The detectors exhibit low noise, good charge-transfer efficiency, and excellent, uniform spectroscopic performance, including in the important soft X-ray band.

astro-ph.IM

The high-speed X-ray camera on AXIS

AXIS is a Probe-class mission concept that will provide high-throughput, high-spatial-resolution X-ray spectral imaging, enabling transformative studies of high-energy astrophysical phenomena. To take advantage of the advanced optics and avoid photon pile-up, the AXIS focal plane requires detectors with readout rates at least 20 times faster than previous soft X-ray imaging spectrometers flying aboard missions such as Chandra and Suzaku, while retaining the low noise, excellent spectral performance, and low power requirements of those instruments. We present the design of the AXIS high-speed X-ray camera, which baselines large-format MIT Lincoln Laboratory CCDs employing low-noise pJFET output amplifiers and a single-layer polysilicon gate structure that allows fast, low-power clocking. These detectors are combined with an integrated high-speed, low-noise ASIC readout chip from Stanford University that provides better performance than conventional discrete solutions at a fraction of their power consumption and footprint. Our complementary front-end electronics concept employs state of the art digital video waveform capture and advanced signal processing to deliver low noise at high speed. We review the current performance of this technology, highlighting recent improvements on prototype devices that achieve excellent noise characteristics at the required readout rate. We present measurements of the CCD spectral response across the AXIS energy band, augmenting lab measurements with detector simulations that help us understand sources of charge loss and evaluate the quality of the CCD backside passivation technique. We show that our technology is on a path that will meet our requirements and enable AXIS to achieve world-class science.

astro-ph.IM

Understanding the effects of charge diffusion in next-generation soft X-ray imagers

To take advantage of high-resolution optics sensitive to a broad energy range, future X-ray imaging instruments will require thick detectors with small pixels. This pixel aspect ratio affects spectral response in the soft X-ray band, vital for many science goals, as charge produced by the photon interaction near the entrance window diffuses across multiple pixels by the time it is collected, and is potentially lost below the imposed noise threshold. In an effort to understand these subtle but significant effects and inform the design and requirements of future detectors, we present simulations of charge diffusion using a variety of detector characteristics and operational settings, assessing spectral response at a range of X-ray energies. We validate the simulations by comparing the performance to that of real CCD detectors tested in the lab and deployed in space, spanning a range of thickness, pixel size, and other characteristics. The simulations show that while larger pixels, higher bias voltage, and optimal backside passivation improve performance, reducing the readout noise has a dominant effect in all cases. We finally show how high-pixel-aspect-ratio devices present challenges for measuring the backside passivation performance due to the magnitude of other processes that degrade spectral response, and present a method for utilizing the simulations to qualitatively assess this performance. Since compelling science requirements often compete technically with each other (high spatial resolution, soft X-ray response, hard X-ray response), these results can be used to find the proper balance for a future high-spatial-resolution X-ray instrument.

astro-ph.IM

Single electron Sensitive Readout (SiSeRO) X-ray detectors: Technological progress and characterization

Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. Characterization was performed for a number of prototype sensors with different device architectures, e.g. location of the internal gate, MOSFET polysilicon gate structure, and location of the trough in the internal gate with respect to the source and drain of the MOSFET (the trough is introduced to confine the charge in the internal gate). Using a buried-channel SiSeRO, we have achieved a charge/current conversion gain of >700 pA per electron, an equivalent noise charge (ENC) of around 6 electrons root mean square (RMS), and a full width half maximum (FWHM) of approximately 140 eV at 5.9 keV at a readout speed of 625 Kpixel/s. In this paper, we discuss the SiSeRO working principle, the readout module developed at Stanford, and the characterization test results of the SiSeRO prototypes. We also discuss the potential to implement Repetitive Non-Destructive Readout (RNDR) with these devices and the preliminary results which can in principle yield sub-electron ENC performance. Additional measurements and detailed device simulations will be essential to mature the SiSeRO technology. However, this new device class presents an exciting technology for next generation astronomical X-ray telescopes requiring fast, low-noise, radiation hard megapixel imagers with moderate spectroscopic resolution.

astro-ph.IM

Photon counting from the vacuum ultraviolet to the short wavelength infrared using semiconductor and superconducting technologies

In the last decade, several photon counting technologies have been developed opening a new window for experiments in the low photon number regime. Several ongoing and future projects in HEP benefit from these developments, which will also have a large impact outside HEP. During the next decade there is a clear technological opportunity to fully develop these sensors and produce a large impact in HEP. In this white paper we discuss the need for photon counting technologies in future projects, and present some technological opportunities to address those needs.

physics.ins-det

Measurement and simulation of charge diffusion in a small-pixel charge-coupled device

Future high-resolution imaging X-ray observatories may require detectors with both fine spatial resolution and high quantum efficiency at relatively high X-ray energies (>5keV). A silicon imaging detector meeting these requirements will have a ratio of detector thickness to pixel size of six or more, roughly twice that of legacy imaging sensors. This implies greater diffusion of X-ray charge packets. We investigate consequences for sensor performance, reporting charge diffusion measurements in a fully-depleted, 50um thick, back-illuminated CCD with 8um pixels. We are able to measure the size distributions of charge packets produced by 5.9 keV and 1.25 keV X-rays in this device. We find that individual charge packets exhibit a gaussian spatial distribution, and determine the frequency distribution of event widths for a range of internal electric field strength levels. We find a standard deviation for the largest charge packets, which occur near the entrance window, of 3.9um. We show that the shape of the event width distribution provides a clear indicator of full depletion and infer the relationship between event width and interaction depth. We compare measured width distributions to simulations. We compare traditional, 'sum-above-threshold' algorithms for event amplitude determination to 2D gaussian fitting of events and find better spectroscopic performance with the former for 5.9 keV events and comparable results at 1.25 keV. The reasons for this difference are discussed. We point out the importance of read noise driven detection thresholds in spectral resolution, and note that the derived read noise requirements for mission concepts such as AXIS and Lynx may be too lax to meet spectral resolution requirements. While we report measurements made with a CCD, we note that they have implications for the performance of high aspect-ratio silicon active pixel sensors as well.

astro-ph.IM

A Small Satellite Version of a Broad-band Soft X-ray Polarimeter

We describe a new implementation of a broad-band soft X-ray polarimeter, substantially based on a previous design. This implementation, the Pioneer Soft X-ray Polarimeter (PiSoX) is a SmallSat, designed for NASA's call for Astrophysics Pioneers, small missions that could be CubeSats, balloon experiments, or SmallSats. As in the REDSoX Polarimeter, the grating arrangement is designed optimally for the purpose of polarimetry with broad-band focussing optics by matching the dispersion of the spectrometer channels to laterally graded multilayers (LGMLs). The system can achieve polarization modulation factors over 90%. For PiSoX, the optics are lightweight Si mirrors in a one-bounce parabolic configuration. High efficiency, blazed gratings from opposite sectors are oriented to disperse to a LGML forming a channel covering the wavelength range from 35 to 75 Angstroms (165 - 350 eV). Upon satellite rotation, the intensities of the dispersed spectra, after reflection and polarizing by the LGMLs, give the three Stokes parameters needed to determine a source's linear polarization fraction and orientation. The design can be extended to higher energies as LGMLs are developed further. We describe examples of the potential scientific return from instruments based on this design.

astro-ph.IM

Astro2020 Activity, Project of State of the Profession Consideration (APC) White Paper: All-Sky Near Infrared Space Astrometry. State of the Profession Considerations: Development of Scanning NIR Detectors for Astronomy

Gaia is a revolutionary space mission developed by ESA and is delivering 5 parameter astrometry, photometry and radial velocities over the whole sky with astrometric accuracies down to a few tens of micro-arcseconds. A weakness of Gaia is that it only operates at optical wavelengths. However, much of the Galactic centre and the spiral arm regions, important for certain studies, are obscured by interstellar extinction and this makes it difficult for Gaia to deeply probe. This problem can be overcome by switching to the Near Infra-Red (NIR) but this is not possible with silicon CCDs. Additionally, to scan the entire sky and make global absolute parallax measurements the spacecraft must have a constant rotation and this requires the detectors operate in Time Delayed Integration (TDI) mode or similar.

astro-ph.IM