arXiv ScienceSearch

arXiv subjects

Christoph Leitner

Publications and source records attributed to Christoph Leitner.

12 recordsLinked to original sources

MuyBridge: Mobile Human Center-of-Mass Estimation from Monocular Video via Sparse Fusion

The 3D center of mass (CoM) is a primary quantity in the biomechanical analysis of sport, rehabilitation, and clinical movement, yet existing 3D pose tracking, mesh recovery, and multi-view triangulation methods either optimize 3D keypoint accuracy without anatomical constraints or carry compute and capture infrastructure too heavy to deploy where CoM tracking is most useful. As a result, the metric CoM remains difficult for coaches and movement analysts to measure from a single camera where athletes train and compete. In this work, we introduce MuyBridge, an on-device system that estimates the athlete's segmental center of mass trajectory from a single phone camera video stream. MuyBridge couples a compact 2D pose network and a distilled single-step monocular depth network through an analytic metric fusion that uses anatomical and physical priors to anchor the metric CoM, requiring no 3D or task-specific supervision. Evaluated on the athletic movements of AthletePose3D (running, track and field, and figure skating), MuyBridge achieves 33-41 mm vertical CoM error and 2.3-6.6% absolute-relative range error (AbsRel) under a one-time calibration, and produces CoM estimates at the 63 FPS pose-estimation rate using asynchronous 2.86 Hz depth updates on iPhone 15. Code is available at: https://github.com/Abradshaw1/Muybridge

cs.CV

Multi-Sensor Edge Angle Detection for Performance Analysis in Ski Jumping

In ski jumping, performance during the gliding phase depends on achieving an aerodynamic posture that maximizes the lift-to-drag ratio. In the V-style technique, the ski edge angle is a key determinant. Reducing the edge angle flattens the skis, increases their effective surface area, and improves aerodynamic lift, ultimately contributing to longer flight distances. Ski edge angles are biomechanically constrained by the limited range of ankle inversion. Current sensing solutions widely quantify these angles using multi-system approaches that combine sensor signals through geometric relations. Such configurations require instrumentation on both the boot and the ski, altering mass distribution, affecting balance during flight, and increasing system complexity. To overcome these limitations, this work presents a wearable sensing system that measures both boot inclination and ski edge angle without modifying the ski surface. Two ultrasonic Time of Flight (ToF) sensors and an in-shoe Inertial Measurement Unit (IMU) are integrated into a single boot-mounted unit. Edge angles are estimated by combining ultrasonic distance measurements with IMU data through geometric reconstruction of the boot-ski configuration. Laboratory experiments demonstrate an angle resolution of 0.4500°, a Mean Absolute Error (MAE) of 0.2640°, and a coefficient of determination exceeding 99\% when compared with reference measurements, indicating strong linear agreement between the two modalities. The system achieves an end-to-end latency of 30.31 ms, enabling real-time feedback suitable for athlete training, while consuming 1.28 mW of power. With a total weight of only 18.6 g the proposed system enables unobtrusive measurement of ski edge angle and boot orientation.

eess.SP

A Time-Synchronized Video Reference System for Data Analysis of Body-Attached Sensor Nodes in Outdoor Scenarios

Wearable body-attached multi-sensor systems enable detailed analysis of human motion and physiological signals in sports, rehabilitation, and movement research. While wireless synchronization techniques can reliably align sensor data streams, interpreting and validating complex or unconstrained activities often requires an additional, objective visual reference. Existing laboratory-grade reference systems provide high accuracy but are impractical for outdoor or field deployments. In contrast, commercial video timecode solutions typically rely on local device-to-device synchronization, which increases the power required to maintain synchronization. This is not desirable in many application scenarios. This paper presents a lightweight Timecode Generator (TCG) that converts Global Navigation Satellite System (GNSS)-derived time directly into a Linear Timecode (LTC) signal that is injected into the recording via a camera audio channel. The approach eliminates continuous handshaking, allowing the system to be activated immediately before the action of interest, thus reducing power consumption and enabling smaller batteries and unobtrusive hardware designs of body-attached sensor nodes. The TCG supports common video frame rates of 24, 25, and 30 frames per second (fps). Experimental evaluation confirms that accurate time alignment is maintained for several minutes without GNSS updates. At 30 fps, the alignment duration is 543 s before a potential frame-level shift occurs. With an average power consumption of 35.37 mW, the system achieves an operating time of up to 75 h when powered by two standard AAA alkaline batteries.

eess.SP

Wireless Low-Latency Synchronization for Body-Worn Multi-Node Systems in Sports

Biomechanical data acquisition in sports demands sub-millisecond synchronization across distributed body-worn sensor nodes. This study evaluates and characterizes the Enhanced ShockBurst (ESB) protocol from Nordic Semiconductor under controlled laboratory conditions for wireless, low-latency command broadcasting, enabling fast event updates in multi-node systems. Through systematic profiling of protocol parameters, including cyclic-redundancy-check modes, bitrate, transmission modes, and payload handling, we achieve a mean Device-to-Device (D2D) latency of 504.99 +- 96.89 us and a network-to-network core latency of 311.78 +- 96.90 us using a one-byte payload with retransmission optimization. This performance significantly outperforms Bluetooth Low Energy (BLE), which is constrained by a 7.5 ms connection interval, by providing deterministic, sub-millisecond synchronization suitable for high-frequency (500 Hz to 1000 Hz) biosignals. These results position ESB as a viable solution for time-critical, multi-node wearable systems in sports, enabling precise event alignment and reliable high-speed data fusion for advanced athlete monitoring and feedback applications.

eess.SY

PuLsE: Accurate and Robust Ultrasound-based Continuous Heart-Rate Monitoring on a Wrist-Worn IoT Device

This work explores the feasibility of employing ultrasound (US) US technology in a wrist-worn IoT device for low-power, high-fidelity heart-rate (HR) extraction. US offers deep tissue penetration and can monitor pulsatile arterial blood flow in large vessels and the surrounding tissue, potentially improving robustness and accuracy compared to PPG. We present an IoT wearable system prototype utilizing a commercial microcontroller MCU employing the onboard ADC to capture high frequency US signals and an innovative low-power US pulser. An envelope filter lowers the bandwidth of the US signal by a factor of >5x, reducing the system's acquisition requirements without compromising accuracy (correlation coefficient between HR extracted from enveloped and raw signals, r(92)=0.99, p<0.001). The full signal processing pipeline is ported to fixed point arithmetic for increased energy efficiency and runs entirely onboard. The system has an average power consumption of 5.8mW, competitive with PPG based systems, and the HR extraction algorithm requires only 68kB of RAM and 71ms of processing time on an ARM Cortex-M4 MCU. The system is estimated to run continuously for more than 7 days on a smartwatch battery. To accurately evaluate the proposed circuit and algorithm and identify the anatomical location on the wrist with the highest accuracy for HR extraction, we collected a dataset from 10 healthy adults at three different wrist positions. The dataset comprises roughly 5 hours of HR data with an average of 80.6+-16.3 bpm. During recording, we synchronized the established ECG gold standard with our US-based method. The comparisons yields a Pearson correlation coefficient of r(92)=0.99, p<0.001 and a mean error of 0.69+-1.99 bpm in the lateral wrist position near the radial artery. The dataset and code have been open-sourced at https://github.com/mgiordy/Ultrasound-Heart-Rate

eess.SP

PEtra: A Flexible and Open-Source PE Loop Tracer for Polymer Thin-Film Transducers

Accurate characterization of ferroelectric properties in polymer piezoelectrics is critical for optimizing the performance of flexible and wearable ultrasound transducers, such as screen-printed PVDF devices. Standard charge measurement techniques, like the Sawyer-Tower circuit, often fall short when applied to ferroelectric polymers due to low-frequency leakage. In this work, we present PEtra, an open-source and versatile piezoelectric loop tracer. PEtra employs a transimpedance amplifier (LMP7721, TI) to convert picoampere-level currents into measurable voltages, covering a frequency range of 0.1 Hz to 5 Hz for a gain setting of 10^7 V/A, and 0.1 Hz to 200 Hz for gain settings between 10^3 V/A to 10^6 V/A (10-fold increments). We demonstrate through simulations and experimental validations that PEtra achieves a sensitivity down to 2 pA, effectively addressing the limitations of traditional charge measurement methods. Compared to the Sawyer-Tower circuit, PEtra directly amplifies currents without the need for a reference capacitor. As a result, it is less susceptible to leakage and can operate at lower frequencies, improving measurement accuracy and reliability. PEtra's design is fully open source, offering researchers and engineers a versatile tool to drive advancements in flexible PVDF transducer technology.

eess.SY

Skilog: A Smart Sensor System for Performance Analysis and Biofeedback in Ski Jumping

In ski jumping, low repetition rates of jumps limit the effectiveness of training. Thus, increasing learning rate within every single jump is key to success. A critical element of athlete training is motor learning, which has been shown to be accelerated by feedback methods. In particular, a fine-grained control of the center of gravity in the in-run is essential. This is because the actual takeoff occurs within a blink of an eye ($\sim$300ms), thus any unbalanced body posture during the in-run will affect flight. This paper presents a smart, compact, and energy-efficient wireless sensor system for real-time performance analysis and biofeedback during ski jumping. The system operates by gauging foot pressures at three distinct points on the insoles of the ski boot at 100Hz. Foot pressure data can either be directly sent to coaches to improve their feedback, or fed into a ML model to give athletes instantaneous in-action feedback using a vibration motor in the ski boot. In the biofeedback scenario, foot pressures act as input variables for an optimized XGBoost model. We achieve a high predictive accuracy of 92.7% for center of mass predictions (dorsal shift, neutral stand, ventral shift). Subsequently, we parallelized and fine-tuned our XGBoost model for a RISC-V based low power parallel processor (GAP9), based on the PULP architecture. We demonstrate real-time detection and feedback (0.0109ms/inference) using our on-chip deployment. The proposed smart system is unobtrusive with a slim form factor (13mm baseboard, 3.2mm antenna) and a lightweight build (26g). Power consumption analysis reveals that the system's energy-efficient design enables sustained operation over multiple days (up to 300 hours) without requiring recharge.

eess.SP

Towards a Novel Ultrasound System Based on Low-Frequency Feature Extraction From a Fully-Printed Flexible Transducer

Ultrasound is a key technology in healthcare, and it is being explored for non-invasive, wearable, continuous monitoring of vital signs. However, its widespread adoption in this scenario is still hindered by the size, complexity, and power consumption of current devices. Moreover, such an application demands adaptability to human anatomy, which is hard to achieve with current transducer technology. This paper presents a novel ultrasound system prototype based on a fully printed, lead-free, and flexible polymer ultrasound transducer, whose bending radius promises good adaptability to the human anatomy. Our application scenario focuses on continuous blood flow monitoring. We implemented a hardware envelope filter to efficiently transpose high-frequency ultrasound signals to a lower-frequency spectrum. This reduces computational and power demands with little to no degradation in the task proposed for this work. We validated our method on a setup that mimics human blood flow by using a flow phantom and a peristaltic pump simulating 3 different heartbeat rhythms: 60, 90 and 120 beats per minute. Our ultrasound setup reconstructs peristaltic pump frequencies with errors of less than 0.05 Hz (3 bpm) from the set pump frequency, both for the raw echo and the enveloped echo. The analog pre-processing showed a promising reduction of signal bandwidth of more than 6x: pulse-echo signals of transducers excited at 12.5 MHz were reduced to about 2 MHz. Thus, allowing consumer MCUs to acquire and elaborate signals within mW-power range in an inexpensive fashion.

physics.med-ph

A Wearable Ultra-Low-Power sEMG-Triggered Ultrasound System for Long-Term Muscle Activity Monitoring

Surface electromyography (sEMG) is a well-established approach to monitor muscular activity on wearable and resource-constrained devices. However, when measuring deeper muscles, its low signal-to-noise ratio (SNR), high signal attenuation, and crosstalk degrade sensing performance. Ultrasound (US) complements sEMG effectively with its higher SNR at high penetration depths. In fact, combining US and sEMG improves the accuracy of muscle dynamic assessment, compared to using only one modality. However, the power envelope of US hardware is considerably higher than that of sEMG, thus inflating energy consumption and reducing the battery life. This work proposes a wearable solution that integrates both modalities and utilizes an EMG-driven wake-up approach to achieve ultra-low power consumption as needed for wearable long-term monitoring. We integrate two wearable state-of-the-art (SoA) US and ExG biosignal acquisition devices to acquire time-synchronized measurements of the short head of the biceps. To minimize power consumption, the US probe is kept in a sleep state when there is no muscle activity. sEMG data are processed on the probe (filtering, envelope extraction and thresholding) to identify muscle activity and generate a trigger to wake-up the US counterpart. The US acquisition starts before muscle fascicles displacement thanks to a triggering time faster than the electromechanical delay (30-100 ms) between the neuromuscular junction stimulation and the muscle contraction. Assuming a muscle contraction of 200 ms at a contraction rate of 1 Hz, the proposed approach enables more than 59% energy saving (with a full-system average power consumption of 12.2 mW) as compared to operating both sEMG and US continuously.

eess.SY

A Human-Centered Machine-Learning Approach for Muscle-Tendon Junction Tracking in Ultrasound Images

Biomechanical and clinical gait research observes muscles and tendons in limbs to study their functions and behaviour. Therefore, movements of distinct anatomical landmarks, such as muscle-tendon junctions, are frequently measured. We propose a reliable and time efficient machine-learning approach to track these junctions in ultrasound videos and support clinical biomechanists in gait analysis. In order to facilitate this process, a method based on deep-learning was introduced. We gathered an extensive dataset, covering 3 functional movements, 2 muscles, collected on 123 healthy and 38 impaired subjects with 3 different ultrasound systems, and providing a total of 66864 annotated ultrasound images in our network training. Furthermore, we used data collected across independent laboratories and curated by researchers with varying levels of experience. For the evaluation of our method a diverse test-set was selected that is independently verified by four specialists. We show that our model achieves similar performance scores to the four human specialists in identifying the muscle-tendon junction position. Our method provides time-efficient tracking of muscle-tendon junctions, with prediction times of up to 0.078 seconds per frame (approx. 100 times faster than manual labeling). All our codes, trained models and test-set were made publicly available and our model is provided as a free-to-use online service on https://deepmtj.org/.

cs.CV

Automatic Tracking of the Muscle Tendon Junction in Healthy and Impaired Subjects using Deep Learning

Recording muscle tendon junction displacements during movement, allows separate investigation of the muscle and tendon behaviour, respectively. In order to provide a fully-automatic tracking method, we employ a novel deep learning approach to detect the position of the muscle tendon junction in ultrasound images. We utilize the attention mechanism to enable the network to focus on relevant regions and to obtain a better interpretation of the results. Our data set consists of a large cohort of 79 healthy subjects and 28 subjects with movement limitations performing passive full range of motion and maximum contraction movements. Our trained network shows robust detection of the muscle tendon junction on a diverse data set of varying quality with a mean absolute error of 2.55$\pm$1 mm. We show that our approach can be applied for various subjects and can be operated in real-time. The complete software package is available for open-source use via: https://github.com/luuleitner/deepMTJ

q-bio.QM

Ultrasound in Locomotion Research -- The Quest for Wider Views

In a systematic review, we investigate current applications of ultrasound in locomotion research. Shortcomings in the range of view of ultrasound systems affect the direct validation of musculoskeletal simulations as inverse approaches have to be applied. We present currently used methods to estimate muscle and tendon length in human plantarflexors.

q-bio.QM