arXiv Science⌕ Search

arXiv subjects

Christiane Kuhl

Publications and source records attributed to Christiane Kuhl.

At least 19 recordsLinked to original sources

What the model knows but does not say: monitoring medical LLMs through verbalized thoughts

Efforts to keep clinical language models safe have concentrated on what enters and leaves the model, but a manipulated model can return an answer that looks entirely ordinary. Here we show that the model's own internal state, rendered in plain language, exposes manipulations the output conceals. Using a natural-language autoencoder, we translate the activations of a multimodal LLM (Gemma-3-27B) into text and let an input-blind judge read this verbalized internal state (the thoughts channel) and the model's answer separately. Across two clinical attack objectives (omitting a pathology, covertly recommending a drug), two input modalities, and two delivery mechanisms, the thoughts channel caught the injection significantly more often than the answer in all eight injected conditions (p<0.05), while both channels held near-zero false-positive rates on clean inputs; the omission result carried over to Llama-3.3-70B. The thoughts channel also registered unsafe clinical requests as harmful while the model was still reading them, before it decided whether to refuse. None of this requires retraining: an off-the-shelf verbalizer and a general-purpose judge are enough.

cs.CL↗

The pretraining domain outweighs the training objective in setting the privacy-utility trade-off of differentially private medical image analysis

Differential privacy limits how much each training image can influence a medical imaging model but lowers its diagnostic accuracy. Pretrained weights reduce this loss. It is unknown whether the pretraining objective or domain improves accuracy more. Here we train chest radiograph classifiers under differential privacy from five starting points on 591,884 radiographs from five datasets. We show that supervised pretraining on chest radiographs ranks first in 24 of 25 combinations of dataset and privacy setting. Measured by the area under the receiver operating characteristic curve, its lead over supervised pretraining on natural images is 2.6% without privacy and 15.3% at the strictest budget. From that starting point, changing the domain improves this area 2.2 to 3.7 times more than changing the objective. Private pretraining on chest radiographs lowers this area by about 5% under privacy but outperforms the three starting points without patient data at the strictest budget. Under privacy, supervised chest radiograph pretraining leads in the worst-performing demographic subgroup.

cs.CV↗

Single-Pass Decision Scores Enable Rapid Classification with Adjustable Thresholds in Medical Multimodal Large Language Models

Multimodal large language models (MLLMs) answer binary clinical questions with a yes or no token, leaving the decision threshold implicit and fixed. We derive a continuous score from a single forward pass by renormalizing the probabilities of the yes and no tokens, allowing the threshold to be adapted to clinical needs without retraining. We evaluated this approach with MedGemma and Gemma-3 (4B and 27B) on six medical imaging datasets. The default threshold was frequently misaligned with the task: for identifying normal chest radiographs, MedGemma-27B labeled every image as abnormal, whereas a validation-selected threshold yielded a sensitivity of 0.945 and a specificity of 0.696. Normalization achieved the highest AUROC on four of six datasets (CheXpert: 0.819 vs. 0.777 for raw and 0.743 for text-elicited probabilities), and a single decision required 53-79 ms on one GPU. This simple post-hoc method turns medical MLLMs into fast classifiers with adjustable operating points. Code: https://github.com/TruhnLab/llm-threshold-calibration

cs.CV↗

Bayesian uncertainty estimation improves clinical decision making in medical AI agents

Machine learning models for medical image analysis typically lack a reliable measure of confidence, limiting their use in ambiguous or atypical cases. Here we show that Monte Carlo dropout, applied to a multi-task chest-radiograph classifier (eight thoracic findings, 137,593 training images), provides an epistemic uncertainty signal that tracks generalisation across training-set scales and flags confident yet error-prone predictions. Adding this signal to the point prediction raised error-detection AUROC from 0.74 to 0.77 ($Δ$AUROC +0.023, 95% CI [+0.014, +0.033]). In a controlled 2x2 factorial experiment, a clinical-decision-support agent exploited this uncertainty only when it was delivered as a binary error-risk flag rather than as raw scores, cutting confident misdiagnoses on unreliable findings from 8.5% to 2.7%. Epistemic uncertainty estimation thus carries decision-relevant information beyond point predictions, but its value for downstream agents depends on how it is communicated.

cs.LG↗

Foundation-model-guided radiogenomic discovery linking cancer genomes to cancer scans

The function of many genes is still unknown, and conventional driver-discovery methods, which rely on how frequently a gene is mutated, cannot assess genes that are only rarely affected. Here we pair Evo~2-based genome analysis with routine clinical imaging to identify gene--phenotype associations at genome-wide scale. For every somatic mutation across three TCGA cohorts (cRCC=clear cell renal cell carcinoma, HCC=hepatocellular carcinoma, and BC=breast cancer; $n = 340$ total), Evo~2 predicts a severity score, with no task-specific training. Per-gene severity summaries are then correlated with radiomic features extracted from paired tumor segmentations, controlling for total mutation burden. In TCGA-cRCC ($n = 162$), this sweep recovers established renal-cancer drivers and identifies 46 additional genes reaching false discovery rate (FDR) significance absent from curated cancer-gene panels, several of which are Mendelian ciliopathy and cytoskeletal-disease genes. These results demonstrate that pairing a genomic language model with widely available clinical imaging can serve as a hypothesis-free discovery tool for gene--imaging associations invisible to conventional approaches.

q-bio.GN↗

A European Multi-Center Breast Cancer MRI Dataset

Early detection of breast cancer is critical for improving patient outcomes. While mammography remains the primary screening modality, magnetic resonance imaging (MRI) is increasingly recommended as a supplemental tool for women with dense breast tissue and those at elevated risk. However, the acquisition and interpretation of multiparametric breast MRI are time-consuming and require specialized expertise, limiting scalability in clinical practice. Artificial intelligence (AI) methods have shown promise in supporting breast MRI interpretation, but their development is hindered by the limited availability of large, diverse, and publicly accessible datasets. To address this gap, we present a publicly available, multi-centre breast MRI dataset collected across six clinical institutions in five European countries. The dataset comprises 741 examinations from women undergoing screening or diagnostic breast MRI and includes malignant, benign, and non-lesion cases. Data were acquired using heterogeneous scanners, field strengths, and acquisition protocols, reflecting real-world clinical variability. In addition, we report baseline benchmark experiments using a transformer-based model to illustrate potential use cases of the dataset and to provide reference performance for future methodological comparisons.

eess.IV↗

Resolution scaling governs DINOv3 transfer performance in chest radiograph classification

Self-supervised learning (SSL) has improved visual representation learning, but its value in chest radiography remains uncertain. DINOv3 extends earlier SSL models through Gram-anchored self-distillation and explicit high-resolution adaptation. Whether these changes improve transfer learning for chest radiograph classification has not been established. We benchmarked DINOv3 against DINOv2 and supervised ImageNet initialization across seven chest radiograph datasets comprising 816,183 radiographs from pediatric and adult cohorts. ViT-B/16 and ConvNeXt-B were evaluated under full fine-tuning at 224 and 512 pixels, with targeted 1024 experiments on three cohorts. Additional analyses examined parameter-efficient adaptation, synthetic label corruption, external validation, frozen 7B features, and computational efficiency. The primary outcome was mean AUROC across labels. In adult cohorts, DINOv3 did not consistently outperform DINOv2 at 224 x 224 pixels, but became the strongest initialization at 512 x 512, especially with ConvNeXt-B. Gains were greatest for small focal and boundary-dependent abnormalities, whereas large-structure findings changed little. The pediatric cohort showed no significant benefit from DINOv3, higher resolution, or backbone choice. Scaling to 1024 x 1024 rarely improved performance and markedly increased computational cost. ConvNeXt-B remained superior to ViT-B/16 under both full and parameter-efficient adaptation. External validation preserved the 512 x 512 DINOv3 advantage, whereas synthetic label corruption showed that this benefit should not be interpreted simply as superior noise robustness. For adult chest radiograph classification, DINOv3 provides its most reliable benefit at 512 x 512 pixels, particularly with ConvNeXt-B. Fully adapted mid-sized models at 512 x 512 pixels provided the best performance-cost trade-off in our benchmark.

cs.CV↗

Hallucination Filtering in Radiology Vision-Language Models Using Discrete Semantic Entropy

To determine whether using discrete semantic entropy (DSE) to reject questions likely to generate hallucinations can improve the accuracy of black-box vision-language models (VLMs) in radiologic image based visual question answering (VQA). This retrospective study evaluated DSE using two publicly available, de-identified datasets: the VQA-Med 2019 benchmark (500 images with clinical questions and short-text answers) and a diagnostic radiology dataset (206 cases: 60 computed tomography scans, 60 magnetic resonance images, 60 radiographs, 26 angiograms) with corresponding ground-truth diagnoses. GPT-4o and GPT-4.1 (Generative Pretrained Transformer; OpenAI) answered each question 15 times using a temperature of 1.0. Baseline accuracy was determined using low-temperature answers (temperature 0.1). Meaning-equivalent responses were grouped using bidirectional entailment checks, and DSE was computed from the relative frequencies of the resulting semantic clusters. Accuracy was recalculated after excluding questions with DSE > 0.6 or > 0.3. p-values and 95% confidence intervals were obtained using bootstrap resampling and a Bonferroni-corrected threshold of p < .004 for statistical significance. Across 706 image-question pairs, baseline accuracy was 51.7% for GPT-4o and 54.8% for GPT-4.1. After filtering out high-entropy questions (DSE > 0.3), accuracy on the remaining questions was 76.3% (retained questions: 334/706) for GPT-4o and 63.8% (retained questions: 499/706) for GPT-4.1 (both p < .001). Accuracy gains were observed across both datasets and largely remained statistically significant after Bonferroni correction. DSE enables reliable hallucination detection in black-box VLMs by quantifying semantic inconsistency. This method significantly improves diagnostic answer accuracy and offers a filtering strategy for clinical VLM applications.

cs.CV↗

MedicalPatchNet: A Patch-Based Self-Explainable AI Architecture for Chest X-ray Classification

Deep neural networks excel in radiological image classification but frequently suffer from poor interpretability, limiting clinical acceptance. We present MedicalPatchNet, an inherently self-explainable architecture for chest X-ray classification that transparently attributes decisions to distinct image regions. MedicalPatchNet splits images into non-overlapping patches, independently classifies each patch, and aggregates predictions, enabling intuitive visualization of each patch's diagnostic contribution without post-hoc techniques. Trained on the CheXpert dataset (223,414 images), MedicalPatchNet matches the classification performance (AUROC 0.907 vs. 0.908) of EfficientNetV2-S, while improving interpretability: MedicalPatchNet demonstrates improved interpretability with higher pathology localization accuracy (mean hit-rate 0.485 vs. 0.376 with Grad-CAM) on the CheXlocalize dataset. By providing explicit, reliable explanations accessible even to non-AI experts, MedicalPatchNet mitigates risks associated with shortcut learning, thus improving clinical trust. Our model is publicly available with reproducible training and inference scripts and contributes to safer, explainable AI-assisted diagnostics across medical imaging domains. We make the code publicly available: https://github.com/TruhnLab/MedicalPatchNet

cs.CV↗

Effect of Reporting Mode and Clinical Experience on Radiologists' Gaze and Image Analysis Behavior in Chest Radiography

Structured reporting (SR) and artificial intelligence (AI) may transform how radiologists interact with imaging studies. This prospective study (July to December 2024) evaluated the impact of three reporting modes: free-text (FT), structured reporting (SR), and AI-assisted structured reporting (AI-SR), on image analysis behavior, diagnostic accuracy, efficiency, and user experience. Four novice and four non-novice readers (radiologists and medical students) each analyzed 35 bedside chest radiographs per session using a customized viewer and an eye-tracking system. Outcomes included diagnostic accuracy (compared with expert consensus using Cohen's $κ$), reporting time per radiograph, eye-tracking metrics, and questionnaire-based user experience. Statistical analysis used generalized linear mixed models with Bonferroni post-hoc tests with a significance level of ($P \le .01$). Diagnostic accuracy was similar in FT ($κ= 0.58$) and SR ($κ= 0.60$) but higher in AI-SR ($κ= 0.71$, $P < .001$). Reporting times decreased from $88 \pm 38$ s (FT) to $37 \pm 18$ s (SR) and $25 \pm 9$ s (AI-SR) ($P < .001$). Saccade counts for the radiograph field ($205 \pm 135$ (FT), $123 \pm 88$ (SR), $97 \pm 58$ (AI-SR)) and total fixation duration for the report field ($11 \pm 5$ s (FT), $5 \pm 3$ s (SR), $4 \pm 1$ s (AI-SR)) were lower with SR and AI-SR ($P < .001$ each). Novice readers shifted gaze towards the radiograph in SR, while non-novice readers maintained their focus on the radiograph. AI-SR was the preferred mode. In conclusion, SR improves efficiency by guiding visual attention toward the image, and AI-prefilled SR further enhances diagnostic accuracy and user satisfaction.

cs.CV↗

Large Language Model-Based Uncertainty-Adjusted Label Extraction for Artificial Intelligence Model Development in Upper Extremity Radiography

Objectives: To evaluate GPT-4o's ability to extract diagnostic labels (with uncertainty) from free-text radiology reports and to test how these labels affect multi-label image classification of musculoskeletal radiographs. Methods: This retrospective study included radiography series of the clavicle (n=1,170), elbow (n=3,755), and thumb (n=1,978). After anonymization, GPT-4o filled out structured templates by indicating imaging findings as present ("true"), absent ("false"), or "uncertain." To assess the impact of label uncertainty, "uncertain" labels of the training and validation sets were automatically reassigned to "true" (inclusive) or "false" (exclusive). Label-image-pairs were used for multi-label classification using ResNet50. Label extraction accuracy was manually verified on internal (clavicle: n=233, elbow: n=745, thumb: n=393) and external test sets (n=300 for each). Performance was assessed using macro-averaged receiver operating characteristic (ROC) area under the curve (AUC), precision recall curves, sensitivity, specificity, and accuracy. AUCs were compared with the DeLong test. Results: Automatic extraction was correct in 98.6% (60,618 of 61,488) of labels in the test sets. Across anatomic regions, label-based model training yielded competitive performance measured by macro-averaged AUC values for inclusive (e.g., elbow: AUC=0.80 [range, 0.62-0.87]) and exclusive models (elbow: AUC=0.80 [range, 0.61-0.88]). Models generalized well on external datasets (elbow [inclusive]: AUC=0.79 [range, 0.61-0.87]; elbow [exclusive]: AUC=0.79 [range, 0.63-0.89]). No significant differences were observed across labeling strategies or datasets (p>=0.15). Conclusion: GPT-4o extracted labels from radiologic reports to train competitive multi-label classification models with high accuracy. Detected uncertainty in the radiologic reports did not influence the performance of these models.

cs.AI↗

T2 Radiomic Features Are More Sensitive Than Mean T2 for Cartilage Load Response: A Stress MRI Study

Objective: To assess response-to-loading in a human cadaveric knee joint model under different loading conditions before and after meniscectomy Design: In this prospective study, stress magnetic resonance imaging was performed using an MR-compatible loading device and quantitative T2 mapping in unloaded (UL), 0$°$ neutrally loaded (LN) and 10$°$ varus loaded (LV) condition before and after meniscectomy. Mean T2 values and four radiomic texture parameters were assessed within the cartilage of medial femur (MF) and medial tibia (MT) for all conditions. Results: Medial joint space width decreased from UL to LN to LV and after meniscectomy (all p<0.05). T2 values did not show any significant dependency on pressure or meniscectomy (all p>0.05). The radiomic parameter variance could assess loading induced textural T2 changes in the MF (UL vs. LN: p=0.042; UL vs. LV: p<0.001; LN vs. LV: p=0.022), and, in part, in the MT (LN vs. LV: p<0.013). Meniscectomy did not significantly alter the T2 mean values or radiomic parameters, respectively. Conclusions: T2-based radiomic features were more sensitive to assess cartilage response to loading than T2-mapping alone.

physics.med-ph↗

Diagnostic Accuracy of Open-Source Vision-Language Models on Diverse Medical Imaging Tasks

This retrospective study evaluated five VLMs (Qwen2.5, Phi-4, Gemma3, Llama3.2, and Mistral3.1) using the MedFMC dataset. This dataset includes 22,349 images from 7,461 patients encompassing chest radiography (19 disease multi-label classifications), colon pathology (tumor detection), endoscopy (colorectal lesion identification), neonatal jaundice assessment (skin color-based treatment necessity), and retinal fundoscopy (5-point diabetic retinopathy grading). Diagnostic accuracy was compared in three experimental settings: visual input only, multimodal input, and chain-of-thought reasoning. Model accuracy was assessed against ground truth labels, with statistical comparisons using bootstrapped confidence intervals (p<.05). Qwen2.5 achieved the highest accuracy for chest radiographs (90.4%) and endoscopy images (84.2%), significantly outperforming the other models (p<.001). In colon pathology, Qwen2.5 (69.0%) and Phi-4 (69.6%) performed comparably (p=.41), both significantly exceeding other VLMs (p<.001). Similarly, for neonatal jaundice assessment, Qwen2.5 (58.3%) and Phi-4 (58.1%) showed comparable leading accuracies (p=.93) significantly exceeding their counterparts (p<.001). All models struggled with retinal fundoscopy; Qwen2.5 and Gemma3 achieved the highest, albeit modest, accuracies at 18.6% (comparable, p=.99), significantly better than other tested models (p<.001). Unexpectedly, multimodal input reduced accuracy for some models and modalities, and chain-of-thought reasoning prompts also failed to improve accuracy. The open-source VLMs demonstrated promising diagnostic capabilities, particularly in chest radiograph interpretation. However, performance in complex domains such as retinal fundoscopy was limited, underscoring the need for further development and domain-specific adaptation before widespread clinical application.

eess.IV↗

RadioRAG: Online Retrieval-augmented Generation for Radiology Question Answering

Large language models (LLMs) often generate outdated or inaccurate information based on static training datasets. Retrieval-augmented generation (RAG) mitigates this by integrating outside data sources. While previous RAG systems used pre-assembled, fixed databases with limited flexibility, we have developed Radiology RAG (RadioRAG), an end-to-end framework that retrieves data from authoritative radiologic online sources in real-time. We evaluate the diagnostic accuracy of various LLMs when answering radiology-specific questions with and without access to additional online information via RAG. Using 80 questions from the RSNA Case Collection across radiologic subspecialties and 24 additional expert-curated questions with reference standard answers, LLMs (GPT-3.5-turbo, GPT-4, Mistral-7B, Mixtral-8x7B, and Llama3 [8B and 70B]) were prompted with and without RadioRAG in a zero-shot inference scenario RadioRAG retrieved context-specific information from Radiopaedia in real-time. Accuracy was investigated. Statistical analyses were performed using bootstrapping. The results were further compared with human performance. RadioRAG improved diagnostic accuracy across most LLMs, with relative accuracy increases ranging up to 54% for different LLMs. It matched or exceeded non-RAG models and the human radiologist in question answering across radiologic subspecialties, particularly in breast imaging and emergency radiology. However, the degree of improvement varied among models; GPT-3.5-turbo and Mixtral-8x7B-instruct-v0.1 saw notable gains, while Mistral-7B-instruct-v0.2 showed no improvement, highlighting variability in RadioRAG's effectiveness. LLMs benefit when provided access to domain-specific data beyond their training data. RadioRAG shows potential to improve LLM accuracy and factuality in radiology question answering by integrating real-time domain-specific data.

cs.CL↗

Private, fair and accurate: Training large-scale, privacy-preserving AI models in medical imaging

Artificial intelligence (AI) models are increasingly used in the medical domain. However, as medical data is highly sensitive, special precautions to ensure its protection are required. The gold standard for privacy preservation is the introduction of differential privacy (DP) to model training. Prior work indicates that DP has negative implications on model accuracy and fairness, which are unacceptable in medicine and represent a main barrier to the widespread use of privacy-preserving techniques. In this work, we evaluated the effect of privacy-preserving training of AI models regarding accuracy and fairness compared to non-private training. For this, we used two datasets: (1) A large dataset (N=193,311) of high quality clinical chest radiographs, and (2) a dataset (N=1,625) of 3D abdominal computed tomography (CT) images, with the task of classifying the presence of pancreatic ductal adenocarcinoma (PDAC). Both were retrospectively collected and manually labeled by experienced radiologists. We then compared non-private deep convolutional neural networks (CNNs) and privacy-preserving (DP) models with respect to privacy-utility trade-offs measured as area under the receiver-operator-characteristic curve (AUROC), and privacy-fairness trade-offs, measured as Pearson's r or Statistical Parity Difference. We found that, while the privacy-preserving trainings yielded lower accuracy, they did largely not amplify discrimination against age, sex or co-morbidity. Our study shows that -- under the challenging realistic circumstances of a real-life clinical dataset -- the privacy-preserving training of diagnostic deep learning models is possible with excellent diagnostic accuracy and fairness.

eess.IV↗

Large Language Models Streamline Automated Machine Learning for Clinical Studies

A knowledge gap persists between machine learning (ML) developers (e.g., data scientists) and practitioners (e.g., clinicians), hampering the full utilization of ML for clinical data analysis. We investigated the potential of the ChatGPT Advanced Data Analysis (ADA), an extension of GPT-4, to bridge this gap and perform ML analyses efficiently. Real-world clinical datasets and study details from large trials across various medical specialties were presented to ChatGPT ADA without specific guidance. ChatGPT ADA autonomously developed state-of-the-art ML models based on the original study's training data to predict clinical outcomes such as cancer development, cancer progression, disease complications, or biomarkers such as pathogenic gene sequences. Following the re-implementation and optimization of the published models, the head-to-head comparison of the ChatGPT ADA-crafted ML models and their respective manually crafted counterparts revealed no significant differences in traditional performance metrics (P>0.071). Strikingly, the ChatGPT ADA-crafted ML models often outperformed their counterparts. In conclusion, ChatGPT ADA offers a promising avenue to democratize ML in medicine by simplifying complex data analyses, yet should enhance, not replace, specialized training and resources, to promote broader applications in medical research and practice.

cs.LG↗

An Ordinal Regression Framework for a Deep Learning Based Severity Assessment for Chest Radiographs

This study investigates the application of ordinal regression methods for categorizing disease severity in chest radiographs. We propose a framework that divides the ordinal regression problem into three parts: a model, a target function, and a classification function. Different encoding methods, including one-hot, Gaussian, progress-bar, and our soft-progress-bar, are applied using ResNet50 and ViT-B-16 deep learning models. We show that the choice of encoding has a strong impact on performance and that the best encoding depends on the chosen weighting of Cohen's kappa and also on the model architecture used. We make our code publicly available on GitHub.

cs.CV↗

Mind the Gap: Federated Learning Broadens Domain Generalization in Diagnostic AI Models

Developing robust artificial intelligence (AI) models that generalize well to unseen datasets is challenging and usually requires large and variable datasets, preferably from multiple institutions. In federated learning (FL), a model is trained collaboratively at numerous sites that hold local datasets without exchanging them. So far, the impact of training strategy, i.e., local versus collaborative, on the diagnostic on-domain and off-domain performance of AI models interpreting chest radiographs has not been assessed. Consequently, using 610,000 chest radiographs from five institutions across the globe, we assessed diagnostic performance as a function of training strategy (i.e., local vs. collaborative), network architecture (i.e., convolutional vs. transformer-based), generalization performance (i.e., on-domain vs. off-domain), imaging finding (i.e., cardiomegaly, pleural effusion, pneumonia, atelectasis, consolidation, pneumothorax, and no abnormality), dataset size (i.e., from n=18,000 to 213,921 radiographs), and dataset diversity. Large datasets not only showed minimal performance gains with FL but, in some instances, even exhibited decreases. In contrast, smaller datasets revealed marked improvements. Thus, on-domain performance was mainly driven by training data size. However, off-domain performance leaned more on training diversity. When trained collaboratively across diverse external institutions, AI models consistently surpassed models trained locally for off-domain tasks, emphasizing FL's potential in leveraging data diversity. In conclusion, FL can bolster diagnostic privacy, reproducibility, and off-domain reliability of AI models and, potentially, optimize healthcare outcomes.

cs.CV↗