arXiv Science⌕ Search

arXiv subjects

Christian Sandow

Publications and source records attributed to Christian Sandow.

3 recordsLinked to original sources

Sub-electron noise with a buried-channel DePFET: characterisation of novel DePFET concepts

Depleted P-channel Field Effect Transistor (DePFET) pixel sensors combine Fano-limited energy resolution with fast, low-noise readout and are used in instruments ranging from particle tracking to X-ray astronomy. In this work, two novel DePFET technologies that address the two factors of the signal-to-noise ratio through fundamental changes to the intrinsic design are characterised: a buried-channel design aimed at reducing the limiting low-frequency noise by weakening the coupling between the channel and Si/SiO$_2$ interface traps, and a super-$g_q$ design intended to increase the charge gain by reducing the effective internal-gate capacitance. Their noise and energy resolution were mapped across the transistor bias space, over a wide temperature range (100-260 K) and for integration times of 0.4-9 $μ$s (readout times of 2-19.2 $μ$s per row), and compared with standard DePFETs as developed for the NewAthena Wide Field Imager (WFI). All three variants reach their lowest noise at about 155 K. The buried-channel device achieves an excellent equivalent noise charge (ENC) of 0.96 e$^-$ (at most 0.83 e$^-$ after subtracting the readout-electronics noise), demonstrating sub-electron noise over a complete 64$\times$64 DePFET matrix in a single readout, alongside a power consumption reduction of more than 50%. The super-$g_q$ DePFET shows a 2.6-fold increase in charge gain (about 1100 pA/e$^-$) but exhibits higher total noise due to an excess noise contribution. The results highlight the potential of the novel DePFETs, with the buried-channel technology offering immediate benefits for low-noise applications such as the WFI.

physics.ins-det↗

Spectroscopic performance of the electrical functional models for the eXTP SFA-T detectors

The Spectroscopy Focusing Array (SFA) is one of the three instruments on the eXTP satellite. It consists of six telescopes plus focal plane cameras, where five are equipped with a Silicon Drift Detector (SDD) array. These five SFA-T (T stands for timing) instruments are used for observations with high time resolution (better than 10 microseconds), high throughput (dead time less than 5 % when observing a 1 Crab source), and good energy resolution (better than 180 eV at 6 keV). This paper presents the spectroscopic performance of the Electrical Functional Modules (EFM) for SFA-T that are assembled and tested at the Max Planck Institute for Extraterrestrial Physics (MPE). A focus lies on the energy resolution at the planned sensor operating temperature of -45 °C. Additionally, the use of a baffle that covers the pixel edges is studied.

astro-ph.IM↗

Characterisation of the NewAthena WFI's DEPFET Flight Production's Operational Parameters

NewAthena's Wide Field Imager (WFI) uses detectors made up from Depleted P-Channel Field Effect Transistor (DEPFET) pixels operated in rolling shutter mode. The Large Detector Array (LDA) contains a 2 $\times$ 2 array of 512 $\times$ 512 pixels Large Detectors (LDs) allowing for a field of view of 40' $\times$ 40' with a frame time of 2 ms while the 64 $\times$ 64 pixels Fast Detector (FD) can observe very bright X-ray sources due to a faster frame time of 0.08 ms. Prototype sensors (64 $\times$ 64 pixels) were used to analyse the sensor's operational range and to optimise the ASIC and DEPFET parameters i.e. current and voltage settings, as well as the DEPFET read-out timing parameters, resulting in an improved energy resolution, reduced noise and otherwise improved sensor characteristics.

astro-ph.IM↗