Resilient Design and Optimal Operation of Battery Energy Storage Systems for Behind-the-Meter Data Center Microgrids

This paper proposes a high-fidelity hyperscale data center load modeling framework that disaggregates facility demand into IT and non-IT components and represents load behavior at second- and minute-level resolutions. Building upon this foundation, a comprehensive multi-phase optimization framework is developed for the planning and resilient design of BESS for BTM data center microgrids. The framework deploys BESS on the load side to act as a dynamic buffer between stochastic demand and generation assets. By smoothing the load spikes and excursions before they are observed by gas turbines, the load-side BESS reduces operational stress and limits conditions that can contribute to SSTI issues, shaft fatigue, system trips, equipment damage, and forced outages. Simultaneously, generation-side BESS resources are optimally sized to provide spinning reserves and enhance system resilience. The proposed methodology co-optimizes BESS with solar, wind, natural gas fuel cells, simple-cycle gas turbines, and combined-cycle gas turbines while incorporating operational, reliability, resiliency, and technology-specific constraints. Simulation results demonstrate the proposed methodology's ability to identify cost-effective, resilient, and operationally feasible designs that satisfy the demanding reliability requirements and energy market challenges of next-generation hyperscale data centers while providing planning insights for investors, developers, and system operators.

eess.SY

Exploiting the Benefits of V2B Application on Peak Shaving of Data Center Loads

The accelerated growth in data center projects has introduced a demand-driven bottleneck throughout power grids and contributed to a substantial increase in carbon emissions. These concerns are fueling discussions on methods to use existing energy assets to drive operational efficiency. To this end, this paper explores the benefits of Vehicle-to-Building (V2B) applications to support peak shaving of data center cooling loads. Initially, a literature review was conducted considering V2B constraints and optimization methods including SoC limitations, EV participation, tariffs, and building loads. This analysis was then used to develop a conceptual case study of a 10 MW data center in Loudoun County, VA by simulating a temperature-dependent load profile and adjusting the V2B participation of 40 commercial and passenger EVs. Simulation results indicate that, depending on seasonal variations in cooling load demands, strategic deployment of V2B assets between 12-5pm can offset gross cooling loads by 13-36%.

eess.SY