arXiv ScienceSearch

arXiv subjects

Ching-Kai Lin

Publications and source records attributed to Ching-Kai Lin.

6 recordsLinked to original sources

A Three-Stage Offline SDRE-Based Control Framework for Human Motion Reproduction on a Suspended Bipedal Robot

Evaluating lower limb exoskeletons directly with human subjects can expose users to risk when actuator faults, joint misalignment, or unsuitable assistance occur. Therefore, captured human motion must first be converted into commands that are executable by the robot hardware and repeatable across trials. This paper presents a three-stage offline command generation framework for reproducing lower limb motion and torque on a suspended bipedal robot platform used as a robotic bench system for exoskeleton evaluation. First, State-Dependent Riccati Equation control is applied to the robot dynamic model to obtain a reference torque trajectory associated with measured lower limb motion. Second, parameterized optimization converts this reference into trapezoidal joint velocity commands subject to motor speed and acceleration limits. Third, a proportional-integral-derivative linear quadratic regulator (PID-LQR) compensation refines the command profiles using experimental tracking data. Walking and squatting motions recorded by a Vicon motion capture system are reproduced on the suspended robot to evaluate tracking accuracy and repeatability. The results show that the average root mean square error (RMSE) and standard deviation (STD) of joint angles across repeated trials remain below 3{\deg} and 0.15{\deg}, respectively. Comparisons of joint angles and torques further show that the proposed method achieves lower maximum RMSE and STD values than the two baseline controllers in all reported cases. These results indicate that the proposed three-stage control provides repeatable and actuator-feasible motion reproduction on a suspended bipedal robot platform as a preliminary test environment for lower limb exoskeleton research before tests involving human subjects.

cs.RO

ReynoldsFlow: Physics-Inspired Spatiotemporal Flow Representation for Video Understanding

Video understanding has largely relied on deep spatiotemporal architectures, including 3D convolutional networks and optical flow (OF) based models. While effective, these methods are often computationally expensive and depend on heuristic motion representations that are sensitive to illumination, scale, and structural changes. To address these limitations, we propose ReynoldsFlow, a physics-inspired representation grounded in the Reynolds transport theorem (RTT) and Helmholtz-Hodge decomposition (HHD). ReynoldsFlow decomposes motion into curl-free (CF) and divergence-free (DF) components, providing a principled and interpretable characterization of scene dynamics. By coupling intensity information with decomposed motion cues, it produces dynamics-aware, texture-preserving features that boost downstream tasks such as pose estimation, action recognition, and tiny object detection. Lightweight and modular, ReynoldsFlow can be readily integrated into existing architectures. Experiments across diverse benchmarks show that ReynoldsFlow consistently matches or surpasses existing approaches, offering improved generalizability and computational efficiency.

cs.CV

Using Few-Shot Learning to Classify Primary Lung Cancer and Other Malignancy with Lung Metastasis in Cytological Imaging via Endobronchial Ultrasound Procedures

This study presents a computer-aided diagnosis (CAD) system to assist early detection of lung metastases during endobronchial ultrasound (EBUS) procedures, significantly reducing follow-up time and enabling timely treatment. Due to limited cytology images and morphological similarities among cells, classifying lung metastases is challenging, and existing research rarely targets this issue directly.To overcome data scarcity and improve classification, the authors propose a few-shot learning model using a hybrid pretrained backbone with fine-grained classification and contrastive learning. Parameter-efficient fine-tuning on augmented support sets enhances generalization and transferability. The model achieved 49.59% accuracy, outperforming existing methods. With 20 image samples, accuracy improved to 55.48%, showing strong potential for identifying rare or novel cancer types in low-data clinical environments.

eess.IV

Towards Enhanced Analysis of Lung Cancer Lesions in EBUS-TBNA -- A Semi-Supervised Video Object Detection Method

This study aims to establish a computer-aided diagnostic system for lung lesions using endobronchial ultrasound (EBUS) to assist physicians in identifying lesion areas. During EBUS-transbronchial needle aspiration (EBUS-TBNA) procedures, hysicians rely on grayscale ultrasound images to determine the location of lesions. However, these images often contain significant noise and can be influenced by surrounding tissues or blood vessels, making identification challenging. Previous research has lacked the application of object detection models to EBUS-TBNA, and there has been no well-defined solution for the lack of annotated data in the EBUS-TBNA dataset. In related studies on ultrasound images, although models have been successful in capturing target regions for their respective tasks, their training and predictions have been based on two-dimensional images, limiting their ability to leverage temporal features for improved predictions. This study introduces a three-dimensional video-based object detection model. It first generates a set of improved queries using a diffusion model, then captures temporal correlations through an attention mechanism. A filtering mechanism selects relevant information from previous frames to pass to the current frame. Subsequently, a teacher-student model training approach is employed to further optimize the model using unlabeled data. By incorporating various data augmentation and feature alignment, the model gains robustness against interference. Test results demonstrate that this model, which captures spatiotemporal information and employs semi-supervised learning methods, achieves an Average Precision (AP) of 48.7 on the test dataset, outperforming other models. It also achieves an Average Recall (AR) of 79.2, significantly leading over existing models.

eess.IV

Using Spatio-Temporal Dual-Stream Network with Self-Supervised Learning for Lung Tumor Classification on Radial Probe Endobronchial Ultrasound Video

The purpose of this study is to develop a computer-aided diagnosis system for classifying benign and malignant lung lesions, and to assist physicians in real-time analysis of radial probe endobronchial ultrasound (EBUS) videos. During the biopsy process of lung cancer, physicians use real-time ultrasound images to find suitable lesion locations for sampling. However, most of these images are difficult to classify and contain a lot of noise. Previous studies have employed 2D convolutional neural networks to effectively differentiate between benign and malignant lung lesions, but doctors still need to manually select good-quality images, which can result in additional labor costs. In addition, the 2D neural network has no ability to capture the temporal information of the ultrasound video, so it is difficult to obtain the relationship between the features of the continuous images. This study designs an automatic diagnosis system based on a 3D neural network, uses the SlowFast architecture as the backbone to fuse temporal and spatial features, and uses the SwAV method of contrastive learning to enhance the noise robustness of the model. The method we propose includes the following advantages, such as (1) using clinical ultrasound films as model input, thereby reducing the need for high-quality image selection by physicians, (2) high-accuracy classification of benign and malignant lung lesions can assist doctors in clinical diagnosis and reduce the time and risk of surgery, and (3) the capability to classify well even in the presence of significant image noise. The AUC, accuracy, precision, recall and specificity of our proposed method on the validation set reached 0.87, 83.87%, 86.96%, 90.91% and 66.67%, respectively. The results have verified the importance of incorporating temporal information and the effectiveness of using the method of contrastive learning on feature extraction.

eess.IV

The interpretation of endobronchial ultrasound image using 3D convolutional neural network for differentiating malignant and benign mediastinal lesions

The purpose of this study is to differentiate malignant and benign mediastinal lesions by using the three-dimensional convolutional neural network through the endobronchial ultrasound (EBUS) image. Compared with previous study, our proposed model is robust to noise and able to fuse various imaging features and spatiotemporal features of EBUS videos. Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a diagnostic tool for intrathoracic lymph nodes. Physician can observe the characteristics of the lesion using grayscale mode, doppler mode, and elastography during the procedure. To process the EBUS data in the form of a video and appropriately integrate the features of multiple imaging modes, we used a time-series three-dimensional convolutional neural network (3D CNN) to learn the spatiotemporal features and design a variety of architectures to fuse each imaging mode. Our model (Res3D_UDE) took grayscale mode, Doppler mode, and elastography as training data and achieved an accuracy of 82.00% and area under the curve (AUC) of 0.83 on the validation set. Compared with previous study, we directly used videos recorded during procedure as training and validation data, without additional manual selection, which might be easier for clinical application. In addition, model designed with 3D CNN can also effectively learn spatiotemporal features and improve accuracy. In the future, our model may be used to guide physicians to quickly and correctly find the target lesions for slice sampling during the inspection process, reduce the number of slices of benign lesions, and shorten the inspection time.

eess.IV