arXiv Science⌕ Search

arXiv subjects

Cheng Liu

Publications and source records attributed to Cheng Liu.

182 records · Page 11Linked to original sources

Anisotropy as a Probe of the Galactic Cosmic Ray Propagation and the Galactic Halo Magnetic Field

The anisotropy of cosmic rays (CRs) in the solar vicinity is generally at- tributed to the CR streaming due to the discrete distribution of CR sources or local magnetic field modulation. Recently, the two dimensional large scale CR anisotropy has been measured by many experiments in TeV-PeV energy range in both hemispheres. The tail-in excess along the tangential direction of the local spiral arm and the loss cone deficit pointing to the north Galactic pole direction agree with what have been obtained in tens to hundreds of GeV. The persistence of the two large scale anisotropy structures in such a wide range of energy suggests that the anisotropy might be due to a global streaming of the Galactic CRs (GCRs). This work tries to extend the observed CR anisotropy picture from solar system to the whole galaxy. In such a case, we can find a new interesting signature, a loop of GCR streaming, of the GCR propagation. We further calculate the overall GCR streaming induced magnetic field, and find a qualitative consistence with the observed structure of the halo magnetic field.

astro-ph.GA↗

Attenuation study for Tibet Water Cherenkov Muon Detector Array-A

This work aims at online calibrating the signal attenuation of the long cable used in Tibet Water Cherenkov Muon detector array-A (Tibet MD-A) under the 37 000 m2 Tibet air shower array. Based on the waterproof connection of the PMT (R3600_06) with the signal cable, and the characters of the high voltage divider, terminal reflection method is explored and used for measuring the signal attenuation with a practical way to eliminate the contribution of the pulse baseline (pedestal). Comparison measurement between it and QDC (Charge-to-Digital Conversion) data taking method are carried out by using open-ended cables, confirming that terminal reflection method is a fast and convenient method, and suitable to online calibrate the signal attenuation for Tibet MD-A. At 26\degree C, the measured attenuation coefficient with the 250-m cable, permanently connected to the PMT, is ~13.9%. Also, the cable frequency response is measured by using the sinusoidal signals, which could be used to study the time dispersion of the real signal produced with Tibet MD-A detector via Fourier analysis.

physics.ins-det↗