arXiv Science⌕ Search

arXiv subjects

Chen Zhao

Publications and source records attributed to Chen Zhao.

At least 361 records · Page 20Linked to original sources

$L^2$-representation of Hodge Modules

Over an arbitrary compact complex space or an arbitrary germ of complex space $X$, we provide fine resolutions of pure Hodge modules with strict supports $IC_X(\mathbb{V})$ via differential forms with locally $L^2$ boundary conditions. When $\mathbb{V}=\mathbb{C}_{X_{\rm reg}}$ is the trivial variation of Hodge structure, we give a solution to a Cheeger-Goresky-MacPherson type conjecture: For any compact complex space $X$, there is a complete hermitian metric $ds^2$ on $X_{\rm reg}$ such that there is a canonical isomorphism $$H^i_{(2)}(X_{\rm reg},ds^2)\simeq IH^i(X),\quad \forall i.$$ Such metric $ds^2$ could be Kähler if $X$ is a Kähler space. As an application, we give a differential geometrical proof of the Kähler package of the hypercohomology of pure Hodge modules. We also prove the Kähler version of Kashiwara's conjecture in the absolute case.

math.AG↗

A Deep Learning-based Method to Extract Lumen and Media-Adventitia in Intravascular Ultrasound Images

Intravascular ultrasound (IVUS) imaging allows direct visualization of the coronary vessel wall and is suitable for the assessment of atherosclerosis and the degree of stenosis. Accurate segmentation and measurements of lumen and median-adventitia (MA) from IVUS are essential for such a successful clinical evaluation. However, current segmentation relies on manual operations, which is time-consuming and user-dependent. In this paper, we aim to develop a deep learning-based method using an encoder-decoder deep architecture to automatically extract both lumen and MA border. Our method named IVUS-U-Net++ is an extension of the well-known U-Net++ model. More specifically, a feature pyramid network was added to the U-Net++ model, enabling the utilization of feature maps at different scales. As a result, the accuracy of the probability map and subsequent segmentation have been improved We collected 1746 IVUS images from 18 patients in this study. The whole dataset was split into a training dataset (1572 images) for the 10-fold cross-validation and a test dataset (174 images) for evaluating the performance of models. Our IVUS-U-Net++ segmentation model achieved a Jaccard measure (JM) of 0.9412, a Hausdorff distance (HD) of 0.0639 mm for the lumen border, and a JM of 0.9509, an HD of 0.0867 mm for the MA border, respectively. Moreover, the Pearson correlation and Bland-Altman analyses were performed to evaluate the correlations of 12 clinical parameters measured from our segmentation results and the ground truth, and automatic measurements agreed well with those from the ground truth (all Ps<0.01). In conclusion, our preliminary results demonstrate that the proposed IVUS-U-Net++ model has great promise for clinical use.

cs.CV↗

A Deep Learning-Based Approach to Extracting Periosteal and Endosteal Contours of Proximal Femur in Quantitative CT Images

Automatic CT segmentation of proximal femur is crucial for the diagnosis and risk stratification of orthopedic diseases; however, current methods for the femur CT segmentation mainly rely on manual interactive segmentation, which is time-consuming and has limitations in both accuracy and reproducibility. In this study, we proposed an approach based on deep learning for the automatic extraction of the periosteal and endosteal contours of proximal femur in order to differentiate cortical and trabecular bone compartments. A three-dimensional (3D) end-to-end fully convolutional neural network, which can better combine the information between neighbor slices and get more accurate segmentation results, was developed for our segmentation task. 100 subjects aged from 50 to 87 years with 24,399 slices of proximal femur CT images were enrolled in this study. The separation of cortical and trabecular bone derived from the QCT software MIAF-Femur was used as the segmentation reference. We randomly divided the whole dataset into a training set with 85 subjects for 10-fold cross-validation and a test set with 15 subjects for evaluating the performance of models. Two models with the same network structures were trained and they achieved a dice similarity coefficient (DSC) of 97.87% and 96.49% for the periosteal and endosteal contours, respectively. To verify the excellent performance of our model for femoral segmentation, we measured the volume of different parts of the femur and compared it with the ground truth and the relative errors between predicted result and ground truth are all less than 5%. It demonstrated a strong potential for clinical use, including the hip fracture risk prediction and finite element analysis.

cs.CV↗

A new approach to extracting coronary arteries and detecting stenosis in invasive coronary angiograms

In stable coronary artery disease (CAD), reduction in mortality and/or myocardial infarction with revascularization over medical therapy has not been reliably achieved. Coronary arteries are usually extracted to perform stenosis detection. We aim to develop an automatic algorithm by deep learning to extract coronary arteries from ICAs.In this study, a multi-input and multi-scale (MIMS) U-Net with a two-stage recurrent training strategy was proposed for the automatic vessel segmentation. Incorporating features such as the Inception residual module with depth-wise separable convolutional layers, the proposed model generated a refined prediction map with the following two training stages: (i) Stage I coarsely segmented the major coronary arteries from pre-processed single-channel ICAs and generated the probability map of vessels; (ii) during the Stage II, a three-channel image consisting of the original preprocessed image, a generated probability map, and an edge-enhanced image generated from the preprocessed image was fed to the proposed MIMS U-Net to produce the final segmentation probability map. During the training stage, the probability maps were iteratively and recurrently updated by feeding into the neural network. After segmentation, an arterial stenosis detection algorithm was developed to extract vascular centerlines and calculate arterial diameters to evaluate stenotic level. Experimental results demonstrated that the proposed method achieved an average Dice score of 0.8329, an average sensitivity of 0.8281, and an average specificity of 0.9979 in our dataset with 294 ICAs obtained from 73 patient. Moreover, our stenosis detection algorithm achieved a true positive rate of 0.6668 and a positive predictive value of 0.7043.

eess.IV↗

ThumbNet: One Thumbnail Image Contains All You Need for Recognition

Although deep convolutional neural networks (CNNs) have achieved great success in computer vision tasks, its real-world application is still impeded by its voracious demand of computational resources. Current works mostly seek to compress the network by reducing its parameters or parameter-incurred computation, neglecting the influence of the input image on the system complexity. Based on the fact that input images of a CNN contain substantial redundancy, in this paper, we propose a unified framework, dubbed as ThumbNet, to simultaneously accelerate and compress CNN models by enabling them to infer on one thumbnail image. We provide three effective strategies to train ThumbNet. In doing so, ThumbNet learns an inference network that performs equally well on small images as the original-input network on large images. With ThumbNet, not only do we obtain the thumbnail-input inference network that can drastically reduce computation and memory requirements, but also we obtain an image downscaler that can generate thumbnail images for generic classification tasks. Extensive experiments show the effectiveness of ThumbNet, and demonstrate that the thumbnail-input inference network learned by ThumbNet can adequately retain the accuracy of the original-input network even when the input images are downscaled 16 times.

cs.CV↗

Wetting equilibrium in a rectangular channel

When a capillary channel with corners is wetted by a fluid, there are regions where the fluid fills the whole cross-section and regions where only the corners are filled by the fluid. The fluid fraction of the partially-filled region, $s^*$, is an important quantity related to the capillary pressure. We calculate the value of $s^*$ for channels with a cross-section slightly deviated from a rectangle: the height is larger in the center than those on the two short sides. We find that a small change in the cross-section geometry leads to a huge change of $s^*$. This result is consistent with experimental observations.

cond-mat.soft↗

On the Potential of Lexico-logical Alignments for Semantic Parsing to SQL Queries

Large-scale semantic parsing datasets annotated with logical forms have enabled major advances in supervised approaches. But can richer supervision help even more? To explore the utility of fine-grained, lexical-level supervision, we introduce Squall, a dataset that enriches 11,276 WikiTableQuestions English-language questions with manually created SQL equivalents plus alignments between SQL and question fragments. Our annotation enables new training possibilities for encoder-decoder models, including approaches from machine translation previously precluded by the absence of alignments. We propose and test two methods: (1) supervised attention; (2) adopting an auxiliary objective of disambiguating references in the input queries to table columns. In 5-fold cross validation, these strategies improve over strong baselines by 4.4% execution accuracy. Oracle experiments suggest that annotated alignments can support further accuracy gains of up to 23.9%.

cs.CL↗

QDNN: DNN with Quantum Neural Network Layers

In this paper, we introduce a quantum extension of classical DNN, QDNN. The QDNN consisting of quantum structured layers can uniformly approximate any continuous function and has more representation power than the classical DNN. It still keeps the advantages of the classical DNN such as the non-linear activation, the multi-layer structure, and the efficient backpropagation training algorithm. Moreover, the QDNN can be used on near-term noisy intermediate-scale quantum processors. A numerical experiment for image classification based on quantum DNN is given, where a high accuracy rate is achieved.

quant-ph↗

Rank-Based Multi-task Learning for Fair Regression

In this work, we develop a novel fairness learning approach for multi-task regression models based on a biased training dataset, using a popular rank-based non-parametric independence test, i.e., Mann Whitney U statistic, for measuring the dependency between target variable and protected variables. To solve this learning problem efficiently, we first reformulate the problem as a new non-convex optimization problem, in which a non-convex constraint is defined based on group-wise ranking functions of individual objects. We then develop an efficient model-training algorithm based on the framework of non-convex alternating direction method of multipliers (NC-ADMM), in which one of the main challenges is to implement an efficient projection oracle to the preceding non-convex set defined based on ranking functions. Through the extensive experiments on both synthetic and real-world datasets, we validated the out-performance of our new approach against several state-of-the-art competitive methods on several popular metrics relevant to fairness learning.

cs.LG↗

Unfairness Discovery and Prevention For Few-Shot Regression

We study fairness in supervised few-shot meta-learning models that are sensitive to discrimination (or bias) in historical data. A machine learning model trained based on biased data tends to make unfair predictions for users from minority groups. Although this problem has been studied before, existing methods mainly aim to detect and control the dependency effect of the protected variables (e.g. race, gender) on target prediction based on a large amount of training data. These approaches carry two major drawbacks that (1) lacking showing a global cause-effect visualization for all variables; (2) lacking generalization of both accuracy and fairness to unseen tasks. In this work, we first discover discrimination from data using a causal Bayesian knowledge graph which not only demonstrates the dependency of the protected variable on target but also indicates causal effects between all variables. Next, we develop a novel algorithm based on risk difference in order to quantify the discriminatory influence for each protected variable in the graph. Furthermore, to protect prediction from unfairness, a fast-adapted bias-control approach in meta-learning is proposed, which efficiently mitigates statistical disparity for each task and it thus ensures independence of protected attributes on predictions based on biased and few-shot data samples. Distinct from existing meta-learning models, group unfairness of tasks are efficiently reduced by leveraging the mean difference between (un)protected groups for regression problems. Through extensive experiments on both synthetic and real-world data sets, we demonstrate that our proposed unfairness discovery and prevention approaches efficiently detect discrimination and mitigate biases on model output as well as generalize both accuracy and fairness to unseen tasks with a limited amount of training samples.

cs.LG↗

Fair Meta-Learning For Few-Shot Classification

Artificial intelligence nowadays plays an increasingly prominent role in our life since decisions that were once made by humans are now delegated to automated systems. A machine learning algorithm trained based on biased data, however, tends to make unfair predictions. Developing classification algorithms that are fair with respect to protected attributes of the data thus becomes an important problem. Motivated by concerns surrounding the fairness effects of sharing and few-shot machine learning tools, such as the Model Agnostic Meta-Learning framework, we propose a novel fair fast-adapted few-shot meta-learning approach that efficiently mitigates biases during meta-train by ensuring controlling the decision boundary covariance that between the protected variable and the signed distance from the feature vectors to the decision boundary. Through extensive experiments on two real-world image benchmarks over three state-of-the-art meta-learning algorithms, we empirically demonstrate that our proposed approach efficiently mitigates biases on model output and generalizes both accuracy and fairness to unseen tasks with a limited amount of training samples.

cs.LG↗

Structure and overstability of resistive modes with runaway electrons

We investigate the effects of runaway electron current on the dispersion relation of resistive magnetohydrodynamic modes in tokamaks. We present a new theoretical model to derive the dispersion relation, which is based on the asymptotic analysis of the resistive layer structure of the modes. It is found that in addition to the conventional resistive layer, a new runaway current layer can emerge whose properties depend on the ratio of the Alfvén velocity to the runaway electron convection speed. Due to the contribution from this layer, both the tearing mode and kink mode will have a real frequency in addition to a growth rate. The derived dispersion relation has been compared with numerical results using both a simplified eigenvalue calculation and a M3D-C1 linear simulation, and good agreement is found in both cases.

physics.plasm-ph↗

Semantic Segmentation Using Deep Learning to Extract Total Extraocular Muscles and Optic Nerve from Orbital Computed Tomography Images

Objectives: Precise segmentation of total extraocular muscles (EOM) and optic nerve (ON) is essential to assess anatomical development and progression of thyroid-associated ophthalmopathy (TAO). We aim to develop a semantic segmentation method based on deep learning to extract the total EOM and ON from orbital CT images in patients with suspected TAO. Materials and Methods: A total of 7,879 images obtained from 97 subjects who underwent orbit CT scans due to suspected TAO were enrolled in this study. Eighty-eight patients were randomly selected into the training/validation dataset, and the rest were put into the test dataset. Contours of the total EOM and ON in all the patients were manually delineated by experienced radiologists as the ground truth. A three-dimensional (3D) end-to-end fully convolutional neural network called semantic V-net (SV-net) was developed for our segmentation task. Intersection over Union (IoU) was measured to evaluate the accuracy of the segmentation results, and Pearson correlation analysis was used to evaluate the volumes measured from our segmentation results against those from the ground truth. Results: Our model in the test dataset achieved an overall IoU of 0.8207; the IoU was 0.7599 for the superior rectus muscle, 0.8183 for the lateral rectus muscle, 0.8481 for the medial rectus muscle, 0.8436 for the inferior rectus muscle and 0.8337 for the optic nerve. The volumes measured from our segmentation results agreed well with those from the ground truth (all R>0.98, P<0.0001). Conclusion: The qualitative and quantitative evaluations demonstrate excellent performance of our method in automatically extracting the total EOM and ON and measuring their volumes in orbital CT images. There is a great promise for clinical application to assess these anatomical structures for the diagnosis and prognosis of TAO.

physics.med-ph↗

A Deep Learning-Based Method for Automatic Segmentation of Proximal Femur from Quantitative Computed Tomography Images

Purpose: Proximal femur image analyses based on quantitative computed tomography (QCT) provide a method to quantify the bone density and evaluate osteoporosis and risk of fracture. We aim to develop a deep-learning-based method for automatic proximal femur segmentation. Methods and Materials: We developed a 3D image segmentation method based on V-Net, an end-to-end fully convolutional neural network (CNN), to extract the proximal femur QCT images automatically. The proposed V-net methodology adopts a compound loss function, which includes a Dice loss and a L2 regularizer. We performed experiments to evaluate the effectiveness of the proposed segmentation method. In the experiments, a QCT dataset which included 397 QCT subjects was used. For the QCT image of each subject, the ground truth for the proximal femur was delineated by a well-trained scientist. During the experiments for the entire cohort then for male and female subjects separately, 90% of the subjects were used in 10-fold cross-validation for training and internal validation, and to select the optimal parameters of the proposed models; the rest of the subjects were used to evaluate the performance of models. Results: Visual comparison demonstrated high agreement between the model prediction and ground truth contours of the proximal femur portion of the QCT images. In the entire cohort, the proposed model achieved a Dice score of 0.9815, a sensitivity of 0.9852 and a specificity of 0.9992. In addition, an R2 score of 0.9956 (p<0.001) was obtained when comparing the volumes measured by our model prediction with the ground truth. Conclusion: This method shows a great promise for clinical application to QCT and QCT-based finite element analysis of the proximal femur for evaluating osteoporosis and hip fracture risk.

physics.med-ph↗

A Novel Method for ECG Signal Classification via One-Dimensional Convolutional Neural Network

This paper presents an end-to-end ECG signal classification method based on a novel segmentation strategy via 1D Convolutional Neural Networks (CNN) to aid the classification of ECG signals. The ECG segmentation strategy named R-R-R strategy (i.e., retaining ECG data between the R peaks just before and after the current R peak) for segmenting the original ECG data into segments in order to train and test the 1D CNN models. The novel strategy mimics physicians in scanning ECG to a greater extent, and maximizes the inherent information of ECG segments. The performance of the classification models for 5-class and 6-class are verified with ECG signals from 48 records of the MIT-BIH arrhythmia database. As the heartbeat types are divided into 5 classes (i.e., normal beat, left bundle branch block beat, right bundle branch block beat, ventricular ectopic beat, and paced beat) in the MIT-BIH, the best classification accuracy, the area under the curve (AUC), the sensitivity and the F1-score reach 99.24%, 0.9994, 0.99 and 0.99, respectively. As the heartbeat types are divided into 6 classes (i.e., normal beat, left bundle branch block beat, right bundle branch block beat, ventricular ectopic beat, paced beat and other beats) in the MIT-BIH, the beat classification accuracy, the AUC, the sensitivity, and the F1-score reach 97.02%, 0.9966, 0.97, and 0.97, respectively. Meanwhile, according to the recommended practice from the Association for Advancement of Medical Instrumentation (AAMI), the heartbeat types are divided into 5 classes (i.e., normal beat, supraventricular ectopic beats, ventricular ectopic beats, fusion beats, and unclassifiable beats), the beat classification accuracy, the sensitivity, and the F1-score reach 97.45%, 0.97, and 0.97, respectively. The experimental results show that the proposed method achieves better performance than the state-of-the-art methods.

eess.SP↗

3D Fusion between Fluoroscopy Angiograms and SPECT Myocardial Perfusion Images to Guide Percutaneous Coronary Intervention

Background. Percutaneous coronary intervention(PCI) in stable coronary artery disease(CAD) is commonly triggered by abnormal myocardial perfusion imaging(MPI). However, due to the possibilities of multivessel disease and variability of coronary artery perfusion distribution, opportunity exists to better align anatomic stenosis with perfusion abnormalities to improve revascularization decisions. This study aims to develop a 3D multi-modality fusion approach to assist decision-making for PCI. Methods. Coronary arteries from fluoroscopic angiography(FA) were reconstructed into 3D artery anatomy. Left ventricular(LV) epicardial surface was extracted from SPECT. The 3D artery anatomy was non-rigidly fused with the LV epicardial surface. The accuracy of the 3D fusion was evaluated via both computer simulation and real patient data. For technical validation, simulated FA and MPI were integrated and then compared with the ground truth from a digital phantom. For clinical validation, FA and SPECT images were integrated and then compared with the ground truth from CT angiograms. Results. In the technical evaluation, the distance-based mismatch error between simulated fluoroscopy and phantom arteries is 1.86(SD:1.43)mm for left coronary arteries(LCA) and 2.21(SD:2.50)mm for right coronary arteries(RCA). In the clinical validation, the distance-based mismatch errors between the fluoroscopy and CT arteries were 3.84(SD:3.15)mm for LCA and 5.55(SD:3.64)mm for RCA. The presence of the corresponding fluoroscopy and CT arteries in the AHA 17-segment model agreed well with a Kappa value of 0.91(95% CI: 0.89-0.93) for LCA and 0.80(CI: 0.67-0.92) for RCA. Conclusions. Our fusion approach is technically accurate to assist PCI decision-making and is clinically feasible to be used in the catheterization laboratory. There is an opportunity to improve the decision-making and outcomes of PCI in stable CAD.

physics.med-ph↗

G-TAD: Sub-Graph Localization for Temporal Action Detection

Temporal action detection is a fundamental yet challenging task in video understanding. Video context is a critical cue to effectively detect actions, but current works mainly focus on temporal context, while neglecting semantic context as well as other important context properties. In this work, we propose a graph convolutional network (GCN) model to adaptively incorporate multi-level semantic context into video features and cast temporal action detection as a sub-graph localization problem. Specifically, we formulate video snippets as graph nodes, snippet-snippet correlations as edges, and actions associated with context as target sub-graphs. With graph convolution as the basic operation, we design a GCN block called GCNeXt, which learns the features of each node by aggregating its context and dynamically updates the edges in the graph. To localize each sub-graph, we also design an SGAlign layer to embed each sub-graph into the Euclidean space. Extensive experiments show that G-TAD is capable of finding effective video context without extra supervision and achieves state-of-the-art performance on two detection benchmarks. On ActivityNet-1.3, it obtains an average mAP of 34.09%; on THUMOS14, it reaches 51.6% at IoU@0.5 when combined with a proposal processing method. G-TAD code is publicly available at https://github.com/frostinassiky/gtad.

cs.CV↗

Potassium Isotope Compositions of Carbonaceous and Ordinary Chondrites: Implications on the Origin of Volatile Depletion in the Early Solar System

Solar system materials are variably depleted in moderately volatile elements (MVEs) relative to the proto-solar composition. To address the origin of this MVE depletion, we conducted a systematic study of high-precision K isotopic composition on 16 carbonaceous chondrites (CCs) of types CM1-2, CO3, CV3, CR2, CK4-5 and CH3 and 28 ordinary chondrites (OCs) covering petrological types 3 to 6 and chemical groups H, L, and LL. We observed significant overall K isotope (delta41K) variations (-1.54 to 0.70 permil). The K isotope compositions of CCs are largely higher than the Bulk Silicate Earth (BSE) value, whereas OCs show typically lower values than BSE. Neither CCs nor OCs show resolvable correlations between K isotopes and chemical groups, petrological types, shock levels, exposure ages, fall or find occurrence, or terrestrial weathering. The lack of a clear trend between K isotopes and K content indicates that the K isotope fractionations were decoupled from the relative elemental K depletions. The range of K isotope variations in the CCs is consistent with a four-component (chondrule, refractory inclusion, matrix and water) mixing model that is able to explain the bulk elemental and isotopic compositions of the main CC groups, but requires a fractionation in K isotopic compositions in chondrules. We propose that the major control of the isotopic compositions of group averages is condensation or vaporization in nebular environments that is preserved in the compositional variation of chondrules. Parent-body processes (aqueous alteration, thermal metamorphism, and metasomatism) can mobilize K and affect the K isotopes in individual samples. In the case of the OCs, the full range of K isotopic variations can only be explained by the combined effects of the size and relative abundances of chondrules, parent-body aqueous and thermal alteration.

astro-ph.EP↗