arXiv ScienceSearch

arXiv subjects

Changjun He

Publications and source records attributed to Changjun He.

4 recordsLinked to original sources

Frequency Security Assessment in Power Systems With High Penetration of Renewables Considering Spatio-Temporal Frequency Distribution

The increasing integration of renewable energy sources exacerbates the spatial and temporal differences in frequency across the power system, posing a serious challenge to the accurate and efficient assessment of system frequency security. To address this issue, a generic effective nodal frequency (ENF) model is first established to concisely characterize nodal frequency dynamics. This model is featured by the effective nodal inertia (ENI), damping, and primary regulation parameters, which retain only the dominant constant component governing nodal frequency dynamic performance. This model enables the tractable analytical formulation of nodal frequency trajectory and the key frequency security indicators. Quantitative analysis under the temporary power disturbance condition reveals that the ENI is the most influential parameter governing frequency security. Consequently, the critical nodal inertia for ensuring nodal frequency security is analytically derived. A system-level frequency security index based on the actual ENI and critical nodal inertia is proposed. On the basis of the proposed index, the system frequency security assessment is carried out with the procedure of ``offline calculation and online evaluation'', which is achieved using a lookup table approach and an interpolation method. Simulations on the modified IEEE 39-bus system verify the effectiveness of the proposed assessment method.

eess.SY

Inertia Matching Principle: Improving Transient Synchronization Stability in Hybrid Power Systems With VSGs and SGs

This paper investigates the transient synchronization stability in power systems hybridized with virtual synchronous generators (VSGs) and synchronous generators (SGs). A relative swing equation model is established to capture the transient synchronization dynamics between the VSG and the SG. Based on this model, both static and dynamic characteristics are systematically analyzed, and a quantitative stability level index is derived to elucidate the underlying stability mechanism. Then, two fundamental inertia matching principles are identified. First, a new instability mechanism induced by improper inertia matching between the VSG and the SG is revealed. It is identified that increasing the VSG's inertia does not monotonically improve transient stability, as commonly presumed. Instead, an optimal inertia matching constant exists that maximizes stability performance. Second, the influence of the VSG share on the synchronization stability is discovered to be strongly influenced by the matching between the VSG's inertia level and its voltage strength (i.e., output impedance). To achieve reliable and robust synchronization stability, proper coordination between the VSG's inertia and virtual impedance is essential. Finally, a coordinated stabilization strategy based on inertia matching and virtual impedance adjustment is proposed to enhance transient synchronization stability performance while suppressing fault current. Simulations conducted on a two-machine system and the IEEE 39-bus system validate the theoretical findings and demonstrate the effectiveness of the proposed strategy.

eess.SY

Transient Stability of Low-Inertia Power Systems with Inverter-Based Generation

This study examines the transient stability of low-inertia power systems with inverter-based generation (IBG) and proposes a sufficient stability criterion. In low-inertia grids, transient interactions are induced between the electromagnetic dynamics of the IBG and the electromechanical dynamics of the synchronous generator (SG) under a fault. For this, a hybrid IBG-SG system is established and a delta-power-frequency model is developed. Based on this model, new mechanisms of transient instability different from those of conventional power systems from the energy perspective are discovered. First, two loss-of-synchronization (LOS) types are identified based on the relative power imbalance owing to the mismatch between the inertia of the IBG and SG under a fault. Second, the relative angle and frequency will jump at the moment of a fault, thus affecting the system energy. Third, the cosine damping coefficient induces a positive energy dissipation, thereby contributing to the system stability. A unified criterion for identifying the two LOS types is proposed using the energy function method. This criterion is proved to be a sufficient stability condition for addressing the effects of the jumps and cosine damping coefficient on the system stability. The new mechanisms and effectiveness of the criterion are verified based on simulation results.

eess.SY

Synchronization Instability of Inverter-Based Generation During Asymmetrical Grid Faults

The transient stability of traditional power systems is concerned with the ability of generators to stay synchronized with the positive-sequence voltage of the network, whether for symmetrical or asymmetrical faults. In contrast, both positive- and negative-sequence synchronizations should be of concern for inverter-based generation (IBG) under asymmetrical faults. This is because the latest grid codes stipulate that IBG should inject dual-sequence current when riding through asymmetrical faults. Currently, much less is known about the synchronization stability during asymmetrical faults. This significantly differs from the positive-sequence synchronization alone because the coupled dual-sequence synchronization is involved. This paper aims to fill this gap. Considering the sequence coupling under asymmetrical faults, the dual-sequence synchronization model of IBG is developed. Based on the model, the conditions that steady-state equilibrium points should follow are identified. The conditions throw light on the possible types of synchronization instability, including the positive-sequence dominated instability and the negative-sequence dominated one. For different types of instability, the dominant factors are analyzed quantitatively, which are reflected by the limit on the current injection amplitude. Exceeding the limit will lead to the loss of both positive- and negative-sequence synchronizations. The model and the analysis are verified by simulations and hardware-in-the-loop experiments.

eess.SY