arXiv ScienceSearch

arXiv subjects

Ch. Finck

Publications and source records attributed to Ch. Finck.

6 recordsLinked to original sources

Calibration of a $\Delta$E-E telescope based on CeBr$_3$ scintillator for secondary charged particles measurements in hadron therapy

Hadrontherapy is an established cancer treatment method that enables a more localized dose deposition compared to conventional radiotherapy, potentially reducing the dose to surrounding healthy tissues in certain clinical cases. However, a key limitation in current treatment planning lies in the limited experimental data available for the characterization of secondary particles generated by nuclear interactions of the primary beam with tissues, which directly impacts the accuracy of Monte Carlo tools and analytical models used in dose calculations. Indeed, this leads to the adoption of larger safety margins and can limit the use of hadrontherapy for treating certain complex or sensitive tumor locations. This work is part of the context of the characterization of secondary charged particles generated by ion beams in the energy range relevant for particle therapy applications, using a $\Delta E-E$ telescope comprising a CeBr$_3$ crystal scintillator and a plastic scintillator. The calibration and response of this telescope to ions commonly used in clinical settings is presented in this work, highlighting adherence to Birks' law for accurate energy measurements. This study is the first to optimize a $\Delta E-E$ telescope combining CeBr$_3$ and plastic scintillators specifically for secondary particle detection in hadrontherapy. It represents an essential step toward the experimental acquisition of nuclear data, enabling accurate measurement and identification of secondary charged particles generated by therapeutic beams in tissue-equivalent materials. The system is designed for use in controlled experimental setups that reproduce clinical conditions, with the goal of improving the predictive accuracy of treatment planning software through enhanced Monte Carlo simulation inputs.

physics.ins-det

The Belle II Detector Upgrades Framework Conceptual Design Report

We describe the planned near-term and potential longer-term upgrades of the Belle II detector at the SuperKEKB electron-positron collider operating at the KEK laboratory in Tsukuba, Japan. These upgrades will allow increasingly sensitive searches for possible new physics beyond the Standard Model in flavor, tau, electroweak and dark sector physics that are both complementary to and competitive with the LHC and other experiments.

hep-ex

Double di ffential fragmentation cross sections measurements of 95 MeV/u 12C on thin targets for hadrontherapy

During therapeutic treatment with heavy ions like carbon, the beam undergoes nuclear fragmentation and secondary light charged particles, in particular protons and alpha particles, are produced. To estimate the dose deposited into the tumors and the surrounding healthy tissues, an accurate prediction on the fluences of these secondary fragments is necessary. Nowadays, a very limited set of double di ffential carbon fragmentation cross sections are being measured in the energy range used in hadrontherapy (40 to 400 MeV/u). Therefore, new measurements are performed to determine the double di ffential cross section of carbon on di erent thin targets. This work describes the experimental results of an experiment performed on May 2011 at GANIL. The double di ffential cross sections and the angular distributions of secondary fragments produced in the 12C fragmentation at 95 MeV/u on thin targets (C, CH2, Al, Al2O3, Ti and PMMA) have been measured. The experimental setup will be precisely described, the systematic error study will be explained and all the experimental data will be presented.

nucl-ex

Comparison of two analysis methods for nuclear reaction measurements of 12C +12C interactions at 95 MeV/u for hadrontherapy

During therapeutic treatment with heavier ions like carbon, the beam undergoes nuclear fragmentation and secondary light charged particles, in particular protons and alpha particles, are produced. To estimate the dose deposited into the tumors and the surrounding healthy tissues, the accuracy must be higher than ($\pm$3% and$\pm$1 mm). Therefore, measurements are performed to determine the double differential cross section for different reactions. In this paper, the analysis of data from 12C +12C reactions at 95 MeV/u are presented. The emitted particles are detected with \DeltaEthin-\DeltaEthick-E telescopes made of a stack of two silicon detectors and a CsI crystal. Two different methods are used to identify the particles. One is based on graphical cuts onto the \DeltaE-E maps, the second is based on the so-called KaliVeda method using a functional description of \DeltaE versus E. The results of the two methods will be presented in this paper as well as the comparison between both.

physics.med-ph

A Large Area Timing RPC

A large area Resistive Plate Chamber (RPC) with a total active surface of 160x10 cm2 was built and tested. The surface was segmented in two 5 cm wide strips readout on both ends with custom, very high frequency, front end electronics. A timing resolution between 50 and 75 ps sigma with an efficiency for Minimum Ionizing Particles (MIPs) larger than 95% was attained over the whole active area, in addition with a position resolution along the strips of 1.2 cm. Despite the large active area per electronic channel, the observed timing resolution is remarkably close to the one previously obtained (50 ps sigma) with much smaller chambers of about 10 cm2 area. These results open perspectives of extending the application of timing RPCs to large area arrays exposed to moderate particle multiplicities, where the low cost, good time resolution, insensitivity to the magnetic field and compact mechanics may be attractive when compared with the standard scintillator-based Time-of-Flight (TOF) technology.

physics.ins-det

Prototype tests for the ALICE TRD

A Transition Radiation Detector (TRD) has been designed to improve the electron identification and trigger capability of the ALICE experiment at the Large Hadron Collider (LHC) at CERN. We present results from tests of a prototype of the TRD concerning pion rejection for different methods of analysis over a momentum range from 0.7 to 2 GeV/c. We investigate the performance of different radiator types, composed of foils, fibres and foams.

nucl-ex