arXiv ScienceSearch

arXiv subjects

Cecilia Mascolo

Publications and source records attributed to Cecilia Mascolo.

At least 19 recordsLinked to original sources

On the Interaction Between Model Compression and Test-Time Adaptation

Deep neural networks deployed in the wild must be both efficient and adaptable, requiring model compression and test-time adaptation (TTA). While both are well studied in isolation, their interaction remains poorly understood. We systematically analyze how structured compression affects a model's ability to adapt under distribution shift. Using ResNet-18 and ViT-Base on CIFAR-10-C and ImageNet-C, we evaluate multiple compression methods combined with standard TTA techniques. We introduce a diagnostic framework that examines representational expressivity and adaptation subspace compatibility. Our results reveal a consistent gap: although compressed models retain high accuracy under supervised adaptation, their TTA performance degrades significantly with increasing compression. We show that this stems from reduced representational diversity and structural constraints that limit recoverability. These effects strongly depend on the compression method, highlighting the need to design compression strategies that preserve adaptability.

cs.LG

Margins, Not Windows: Training-Free Per-Step Lossy Speculative Decoding

Speculative decoding accelerates LLM inference by drafting candidate tokens and verifying them in parallel. Tree-attention drafters such as EAGLE-3 are widely adopted, yet typically hold two decisions fixed: (1) a strict token-match verification rule and (2) a static draft-tree shape. Prior work relaxes each in isolation under limiting assumptions: long draft chains for training-free lossy verification, and adaptive tree shaping under a fixed token budget. We introduce AdaptiveSpec, a training-free per-step speculative decoding method that adapts both decisions from internal signals already produced during decoding. A per-step margin rule promotes a mismatched draft-proposed token when the ratio of the target's probability on the drafted token to its top-1 probability exceeds a threshold with no dependence on draft length or underlying drafter architecture. A per-step tree policy adjusts the draft tree's depth, width, and node count directly from a fused signal of draft top-1 confidence and a rolling acceptance history capturing recent draft-target agreement, allowing the total draft count to vary rather than only be redistributed. The two adaptations operate on orthogonal axes and compound in effect. Implemented on the SGLang production-grade serving engine, AdaptiveSpec improves throughput over the state-of-the-art autoregressive speculative decoding method EAGLE-3 by up to 56%, recovering 93% to fully lossless task accuracy across GSM8K, MATH-500, and HumanEval on three target models (DeepSeek-R1-Distill-Llama-8B, Llama-3.1-8B-Instruct, Qwen3-8B).

cs.CL

RA-QA: A Benchmarking System for Respiratory Audio Question Answering Under Real-World Heterogeneity

As conversational multimodal AI tools are increasingly adopted to process patient data for health assessment, robust benchmarks are needed to measure progress and expose failure modes under realistic conditions. Despite the importance of respiratory audio for mobile health screening, respiratory audio question answering remains underexplored, with existing studies evaluated narrowly and lacking real-world heterogeneity across modalities, devices, and question types. We hence introduce the \textbf{Respiratory-Audio Question-Answering (RA-QA) benchmark}, including a standardized data generation pipeline, a comprehensive multimodal QA collection, and a unified evaluation protocol. RA-QA harmonizes public RA datasets into a collection of 9 million format-diverse QA pairs covering diagnostic and contextual attributes. We benchmark general audio-language models as well as domain-specific architectures, establishing reproducible reference points and showing how current approaches fail under heterogeneity.

cs.SD

WEQA: Wearable hEalth Question Answering with Query-Adaptive Agentic Reasoning

Language models are remarkably capable at medical question answering, in some cases surpassing the accuracy of general physicians. However, answering questions about wearable health data remains challenging and understudied, as these ubiquitous sensors produce continuous, high-dimensional, and longitudinal data, which is non-trivial to align with text-centric distributions in LLM pretraining. The diversity of sensor modalities and user intents cannot be effectively handled by a fixed reasoning workflow or a single pretrained foundation model. To address these challenges, we propose WEQA, a query-adaptive agent framework that unifies LLM reasoning with specialized wearable analytical and modeling tools. An LLM controller is employed to synthesize execution plans and dynamically route each query to the appropriate combination of sensor analysis and pretrained models, and perform grounded response auditing with external knowledge. We also curate a benchmark spanning four open wearable datasets comprising analytic and predictive tasks in three different health domains. Experiments show that our framework is 24% more accurate than LLM and agentic baselines, and a blinded study with 12 medical experts and 8 users shows substantial gains in usefulness and clinical soundness.

cs.AI

ADAPTOOD: Uncertainty-Aware Fine-Tuning for Out-of-Distribution ECG Time Series Models

Data samples used for training often differ from those encountered during fine-tuning and deployment, and while ML models show promise, their performance remains limited when only small annotated datasets are available. Performance often degrades under distribution shifts caused by diverse sensors, populations, and application settings. Although pre-training helps, models frequently encounter out-of-distribution (OOD) data in real-world settings, leading to reduced robustness. Existing adaptation methods usually assume fixed distribution shifts and struggle when multiple types or severities occur. In particular, they overlook shift severity, for example treating adaptation to a large familiar dataset the same as adaptation to a small dataset with a new task, which limits generalisation. To address this, we propose ADAPTOOD, a novel framework that leverages data uncertainty to quantify distribution shift severity and guide fine-tuning for time series. This uncertainty measures how strongly samples from the target deployment distribution deviate from the pre-training distribution, providing a direct signal of OOD severity. Our framework combines this uncertainty with low-rank model updates and adaptive hyperparameter optimisation to improve adaptation. We show that ADAPTOOD achieves up to 7% higher accuracy and 12.9% higher precision than existing methods in OOD tasks, maintaining strong performance as distribution shift severity increases.

cs.LG

Tempora: Characterising the Time-Contingent Utility of Online Test-Time Adaptation

Test-time adaptation (TTA) offers a compelling remedy for machine learning (ML) models that degrade under domain shifts, improving generalisation on-the-fly with only unlabelled samples. This flexibility suits real deployments, yet conventional evaluations unrealistically assume unbounded processing time, overlooking the accuracy-latency trade-off. As ML increasingly underpins latency-sensitive and user-facing use-cases, temporal pressure constrains the viability of adaptable inference; predictions arriving too late to act on are futile. We introduce Tempora, a framework for evaluating TTA under this pressure. It consists of temporal scenarios that model deployment constraints, evaluation protocols that operationalise measurement, and time-contingent utility metrics that quantify the accuracy-latency trade-off. We instantiate the framework with three such metrics: (1) discrete utility for asynchronous streams with hard deadlines, (2) continuous utility for interactive settings where value decays with latency, and (3) amortised utility for budget-constrained deployments. By applying Tempora to 11 TTA methods, we find that rank instability persists across 750+ temporal evaluations spanning diverse datasets, models, and hardware platforms; i.e., conventional rankings do not predict rankings under temporal pressure. The highest-utility method varies with the shift and temporal pressure, with no clear winner. By enabling systematic evaluation across diverse temporal constraints for the first time, Tempora reveals when and why rankings change, offering practitioners a lens for method selection and researchers a target for deployable adaptation. Code: https://github.com/sudotensor/tempora.

cs.LG

Beyond Hearing: Learning Task-Agnostic ExG Representations from Earphones via Physiology-Informed Tokenization

Electrophysiological (ExG) signals offer valuable insights into human physiology, yet building foundation models that generalize across everyday tasks remains challenging due to two key limitations: (i)~insufficient data diversity, as most ExG recordings are collected in controlled labs with bulky, expensive devices; and (ii)~task-specific model designs that require tailored processing (i.e., targeted frequency filters) and architectures, which limit generalization across tasks. To address these challenges, we introduce an approach for scalable, task-agnostic ExG monitoring in the wild. We collected 50 hours of unobtrusive free-living ExG data with an earphone-based hardware prototype to narrow the data diversity gap. At the core of our approach is Physiology-informed Multi-band Tokenization (PiMT), which decomposes ExG signals into 12 physiology-informed tokens, followed by a reconstruction task to learn robust representations. This enables adaptive feature recognition across the full frequency spectrum while capturing task-relevant information. Experiments on our new DailySense dataset, the first to enable ExG-based analysis across five human senses, together with four public ExG benchmarks, demonstrate that PiMT consistently outperforms state-of-the-art methods across diverse tasks.

eess.AS

RAMoEA-QA: Hierarchical Specialization for Robust Respiratory Audio Question Answering

Conversational generative AI is increasingly explored in healthcare, where models must integrate heterogeneous patient signals and support diverse interaction styles while producing clinically meaningful outputs. In respiratory care, non-invasive audio recordings captured with sensing devices offer a scalable route to screening and longitudinal monitoring, but heterogeneity is particularly acute: recordings vary across devices, environments, and acquisition protocols, and queries may vary in intent, answer format, and prediction objective. Existing biomedical audio-language question answering systems for respiratory assessment are starting to emerge, but they are typically built as single-path models, processing all inputs through the same acoustic and language pathway despite variation in recording conditions and query types. They are also usually evaluated in relatively limited settings, leaving open their robustness under realistic distribution shifts, including changes in acquisition domains, modality, and clinical task. To address this gap, we introduce RAMoEA-QA, the first RA QA model designed to support input-dependent specialization across heterogeneous recordings and query types within a unified hierarchical two-stage framework. We study this design in a unified RA QA setting spanning clinical and self-recorded, multi-device acquisition settings, question formats, and both discrete and continuous targets. Across in-domain and controlled-shift evaluations, RAMoEA-QA improves over matched monolithic baselines and routing controls, reaching 0.72 in in-domain test accuracy (vs. 0.61 and 0.67 for single-path baselines) on discriminative tasks, while also achieving the best regression performance and stronger average transfer under dataset, modality, and task shifts, including gains of up to 23 percentage points in accuracy on the COPD modality-shift setting.

cs.SD

Wearable Foundation Models Should Go Beyond Static Encoders

Wearable foundation models (WFMs), trained on large volumes of data collected by affordable, always-on devices, have demonstrated strong performance on short-term, well-defined health monitoring tasks, including activity recognition, fitness tracking, and cardiovascular signal assessment. However, most existing WFMs primarily map short temporal windows to predefined labels via static encoders, emphasizing retrospective prediction rather than reasoning over evolving personal history, context, and future risk trajectories. As a result, they are poorly suited for modeling chronic, progressive, or episodic health conditions that unfold over weeks, months or years. Hence, we argue that WFMs must move beyond static encoders and be explicitly designed for longitudinal, anticipatory health reasoning. We identify three foundational shifts required to enable this transition: (1) Structurally rich data, which goes beyond isolated datasets or outcome-conditioned collection to integrated multimodal, long-term personal trajectories, and contextual metadata, ideally supported by open and interoperable data ecosystems; (2) Longitudinal-aware multimodal modeling, which prioritizes long-context inference, temporal abstraction, and personalization over cross-sectional or population-level prediction; and (3) Agentic inference systems, which move beyond static prediction to support planning, decision-making, and clinically grounded intervention under uncertainty. Together, these shifts reframe wearable health monitoring from retrospective signal interpretation toward continuous, anticipatory, and human-aligned health support.

cs.LG

CHOMP: Multimodal Chewing Side Detection with Earphones

Chewing side preference (CSP) has been identified both as a risk factor for temporomandibular disorders (TMD) and behavioral manifestation. Despite TMDs affecting roughly one third of the global population, assessment mainly relies on clinical examinations and self-reports, offering limited insight into everyday jaw function. Continuous CSP monitoring could provide an objective proxy for functional asymmetries. Prior wearable approaches, however, mostly use specialized form factors and demonstrate limited performance. We therefore present CHOMP, the first system for chewing side detection using earphones. Employing OpenEarable 2.0, we collected data from 20 participants with microphones, a bone-conduction microphone, IMU, PPG, and a pressure sensor across eleven foods, five non-chewing activities, and three noise conditions. We apply the Continuous Wavelet Transform to each sensing modality and use the resulting multi-channel scalograms as inputs to CNN-based classifiers. Microphones achieve the strongest single-sensor unit performance, with median F1 scores of 94.5% in leave-one-food-out (LOFO) and 92.6% in leave-one-subject-out (LOSO) cross-validations. Fusing sensing modalities further improves performance to 97.7% for LOFO and 95.4% for LOSO, with additional evaluations under noise interference indicating robust performance. Our results establish earphones as a practical platform for continuous CSP monitoring, enabling clinicians and patients to assess jaw function in everyday life.

cs.HC

Rethinking Large Language Models For Irregular Time Series Classification In Critical Care

Time series data from the Intensive Care Unit (ICU) provides critical information for patient monitoring. While recent advancements in applying Large Language Models (LLMs) to time series modeling (TSM) have shown great promise, their effectiveness on the irregular ICU data, characterized by particularly high rates of missing values, remains largely unexplored. This work investigates two key components underlying the success of LLMs for TSM: the time series encoder and the multimodal alignment strategy. To this end, we establish a systematic testbed to evaluate their impact across various state-of-the-art LLM-based methods on benchmark ICU datasets against strong supervised and self-supervised baselines. Results reveal that the encoder design is more critical than the alignment strategy. Encoders that explicitly model irregularity achieve substantial performance gains, yielding an average AUPRC increase of $12.8\%$ over the vanilla Transformer. While less impactful, the alignment strategy is also noteworthy, with the best-performing semantically rich, fusion-based strategy achieving a modest $2.9\%$ improvement over cross-attention. However, LLM-based methods require at least 10$\times$ longer training than the best-performing irregular supervised models, while delivering only comparable performance. They also underperform in data-scarce few-shot learning settings. These findings highlight both the promise and current limitations of LLMs for irregular ICU time series. The code is available at https://github.com/mHealthUnimelb/LLMTS.

cs.LG

A Survey of Earable Technology: Trends, Tools, and the Road Ahead

Earable devices, wearables positioned in or around the ear, are undergoing a rapid transformation from audio-centric accessories into multifunctional systems for interaction, contextual awareness, and health monitoring. This evolution is driven by commercial trends emphasizing sensor integration and by a surge of academic interest exploring novel sensing capabilities. Building on the foundation established by earlier surveys, this work presents a timely and comprehensive review of earable research published since 2022. We analyze over one hundred recent studies to characterize this shifting research landscape, identify emerging applications and sensing modalities, and assess progress relative to prior efforts. In doing so, we address three core questions: how has earable research evolved in recent years, what enabling resources are now available, and what opportunities remain for future exploration. Through this survey, we aim to provide both a retrospective and forward-looking view of earable technology as a rapidly expanding frontier in ubiquitous computing. In particular, this review reveals that over the past three years, researchers have discovered a variety of novel sensing principles, developed many new earable sensing applications, enhanced the accuracy of existing sensing tasks, and created substantial new resources to advance research in the field. Based on this, we further discuss open challenges and propose future directions for the next phase of earable research.

cs.HC

SensorLM: Learning the Language of Wearable Sensors

We present SensorLM, a family of sensor-language foundation models that enable wearable sensor data understanding with natural language. Despite its pervasive nature, aligning and interpreting sensor data with language remains challenging due to the lack of paired, richly annotated sensor-text descriptions in uncurated, real-world wearable data. We introduce a hierarchical caption generation pipeline designed to capture statistical, structural, and semantic information from sensor data. This approach enabled the curation of the largest sensor-language dataset to date, comprising over 59.7 million hours of data from more than 103,000 people. Furthermore, SensorLM extends prominent multimodal pretraining architectures (e.g., CLIP, CoCa) and recovers them as specific variants within a generic architecture. Extensive experiments on real-world tasks in human activity analysis and healthcare verify the superior performance of SensorLM over state-of-the-art in zero-shot recognition, few-shot learning, and cross-modal retrieval. SensorLM also demonstrates intriguing capabilities including scaling behaviors, label efficiency, sensor captioning, and zero-shot generalization to unseen tasks.

cs.LG

Electrocardiogram-Language Model for Few-Shot Question Answering with Meta Learning

Electrocardiogram (ECG) interpretation requires specialized expertise, often involving synthesizing insights from ECG signals with complex clinical queries posed in natural language. The scarcity of labeled ECG data coupled with the diverse nature of clinical inquiries presents a significant challenge for developing robust and adaptable ECG diagnostic systems. This work introduces a novel multimodal meta-learning method for few-shot ECG question answering, addressing the challenge of limited labeled data while leveraging the rich knowledge encoded within large language models (LLMs). Our LLM-agnostic approach integrates a pre-trained ECG encoder with a frozen LLM (e.g., LLaMA and Gemma) via a trainable fusion module, enabling the language model to reason about ECG data and generate clinically meaningful answers. Extensive experiments demonstrate superior generalization to unseen diagnostic tasks compared to supervised baselines, achieving notable performance even with limited ECG leads. For instance, in a 5-way 5-shot setting, our method using LLaMA-3.1-8B achieves an accuracy of 84.6%, 77.3%, and 69.6% on single verify, choose and query question types, respectively. These results highlight the potential of our method to enhance clinical ECG interpretation by combining signal processing with the nuanced language understanding capabilities of LLMs, particularly in data-constrained scenarios.

cs.LG

LeanTTA: A Backpropagation-Free and Stateless Approach to Quantized Test-Time Adaptation on Edge Devices

While there are many advantages to deploying machine learning models on edge devices, the resource constraints of mobile platforms, the dynamic nature of the environment, and differences between the distribution of training versus in-the-wild data make such deployments challenging. Current test-time adaptation methods are often memory-intensive and not designed to be quantization-compatible or deployed on low-resource devices. To address these challenges, we present LeanTTA, a novel backpropagation-free and stateless framework for quantized test-time adaptation tailored to edge devices. Our approach minimizes computational costs by dynamically updating normalization statistics without backpropagation, which frees LeanTTA from the common pitfall of relying on large batches and historical data, making our method robust to realistic deployment scenarios. Our approach is the first to enable further computational gains by combining partial adaptation with quantized module fusion. We validate our framework across sensor modalities, demonstrating significant improvements over state-of-the-art TTA methods, including a 15.7% error reduction, peak memory usage of only 11.2MB for ResNet18, and fast adaptation within an order-of-magnitude of normal inference speeds on-device. LeanTTA provides a robust solution for achieving the right trade offs between accuracy and system efficiency in edge deployments, addressing the unique challenges posed by limited data and varied operational conditions.

cs.LG

Towards Open Respiratory Acoustic Foundation Models: Pretraining and Benchmarking

Respiratory audio, such as coughing and breathing sounds, has predictive power for a wide range of healthcare applications, yet is currently under-explored. The main problem for those applications arises from the difficulty in collecting large labeled task-specific data for model development. Generalizable respiratory acoustic foundation models pretrained with unlabeled data would offer appealing advantages and possibly unlock this impasse. However, given the safety-critical nature of healthcare applications, it is pivotal to also ensure openness and replicability for any proposed foundation model solution. To this end, we introduce OPERA, an OPEn Respiratory Acoustic foundation model pretraining and benchmarking system, as the first approach answering this need. We curate large-scale respiratory audio datasets (~136K samples, over 400 hours), pretrain three pioneering foundation models, and build a benchmark consisting of 19 downstream respiratory health tasks for evaluation. Our pretrained models demonstrate superior performance (against existing acoustic models pretrained with general audio on 16 out of 19 tasks) and generalizability (to unseen datasets and new respiratory audio modalities). This highlights the great promise of respiratory acoustic foundation models and encourages more studies using OPERA as an open resource to accelerate research on respiratory audio for health. The system is accessible from https://github.com/evelyn0414/OPERA.

cs.SD

StatioCL: Contrastive Learning for Time Series via Non-Stationary and Temporal Contrast

Contrastive learning (CL) has emerged as a promising approach for representation learning in time series data by embedding similar pairs closely while distancing dissimilar ones. However, existing CL methods often introduce false negative pairs (FNPs) by neglecting inherent characteristics and then randomly selecting distinct segments as dissimilar pairs, leading to erroneous representation learning, reduced model performance, and overall inefficiency. To address these issues, we systematically define and categorize FNPs in time series into semantic false negative pairs and temporal false negative pairs for the first time: the former arising from overlooking similarities in label categories, which correlates with similarities in non-stationarity and the latter from neglecting temporal proximity. Moreover, we introduce StatioCL, a novel CL framework that captures non-stationarity and temporal dependency to mitigate both FNPs and rectify the inaccuracies in learned representations. By interpreting and differentiating non-stationary states, which reflect the correlation between trends or temporal dynamics with underlying data patterns, StatioCL effectively captures the semantic characteristics and eliminates semantic FNPs. Simultaneously, StatioCL establishes fine-grained similarity levels based on temporal dependencies to capture varying temporal proximity between segments and to mitigate temporal FNPs. Evaluated on real-world benchmark time series classification datasets, StatioCL demonstrates a substantial improvement over state-of-the-art CL methods, achieving a 2.9% increase in Recall and a 19.2% reduction in FNPs. Most importantly, StatioCL also shows enhanced data efficiency and robustness against label scarcity.

cs.LG

RespLLM: Unifying Audio and Text with Multimodal LLMs for Generalized Respiratory Health Prediction

The high incidence and mortality rates associated with respiratory diseases underscores the importance of early screening. Machine learning models can automate clinical consultations and auscultation, offering vital support in this area. However, the data involved, spanning demographics, medical history, symptoms, and respiratory audio, are heterogeneous and complex. Existing approaches are insufficient and lack generalizability, as they typically rely on limited training data, basic fusion techniques, and task-specific models. In this paper, we propose RespLLM, a novel multimodal large language model (LLM) framework that unifies text and audio representations for respiratory health prediction. RespLLM leverages the extensive prior knowledge of pretrained LLMs and enables effective audio-text fusion through cross-modal attentions. Instruction tuning is employed to integrate diverse data from multiple sources, ensuring generalizability and versatility of the model. Experiments on five real-world datasets demonstrate that RespLLM outperforms leading baselines by an average of 4.6% on trained tasks, 7.9% on unseen datasets, and facilitates zero-shot predictions for new tasks. Our work lays the foundation for multimodal models that can perceive, listen to, and understand heterogeneous data, paving the way for scalable respiratory health diagnosis.

cs.LG